{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1EA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1EA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1EA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1EA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV6011-1EA15 motor protection circuit breaker, size S00, 4 A rated operational current, Class 10 thermal-magnetic overload and magnetic short-circuit release, 690 V AC-3, 50/60 Hz, screw terminals, snap-on DIN rail mount.","salesMarkdown":"It combines a thermal overload relay (Class 10 trip characteristic) with a magnetic short-circuit release in a single 3-pole device. The 4 A rated operational current at AC-3 duty means it directly protects a motor drawing that full-load current, with the thermal element tracking the heating curve of the motor windings. Rated at 690 V AC-3 maximum and 50/60 Hz, it covers standard three-phase motor loads across most industrial voltages. The magnetic short-circuit release clears faults fast enough to coordinate with downstream contactors and upstream breakers in a selectivity study. The 45 mm width (three modular units) and 96 mm depth fit standard motor control center buckets and small enclosures. Terminals accept 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²) — AWG equivalents 2x (18 to 12) for main contacts, 2x (20 to 16) for auxiliary. Screw torque 0.8 to 1.2 N·m on the main terminals. ## Ambient conditions and durability Withstands 25 g shock at 11 ms per IEC 60068-2-27. Relative humidity 10 to 95 % during operation — suitable for unconditioned plant-floor environments.","metaTitle":"Siemens 3RV6011-1EA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-1EA15 SIRIUS motor protection circuit breaker, 4 A rated current, Class 10 thermal-magnetic trip. 690 V AC-3, 50/60 Hz. Screw and snap-on DIN rail mount. Current pr","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"4 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.8 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/312a469067e37e5790edf8b9503cb55a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621263&mlfb=3RV6011-1EA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1EA15/alternatives.json"},"ai":{"faq":[{"question":"What is the 3RV6011-1EA15 rated current and trip class?","answer":"Rated operational current is 4 A at AC-3, with a Class 10 thermal overload trip characteristic."},{"question":"Will the 3RV6011-1EA15 drop into a panel wired for the 3RV6011-0CA10?","answer":"Both are size S00, same 45 mm width and DIN-rail mount, so mechanical fit is identical. However, the 0CA10 has a different current rating and trip setting — verify the motor FLA matches the 4 A rating of the 1EA15 before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1EA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1EA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}