{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1FA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1FA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1FA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1FA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV6011-1FA10 motor protection circuit breaker, size S00, 3-pole, thermal-magnetic overload and short-circuit release, rated operational current 5 A at AC-3 / 400 V, Class 10 trip, 690 V insulation voltage, screw terminals, DIN rail mount.","salesMarkdown":"The 5 A rated current at AC-3 / 400 V is the motor-load rating — it governs what size motor this breaker protects. For a standard 400 V four-pole induction motor, 5 A typically corresponds to a 2.2 kW output. The 3-pole construction is standard for three-phase motor circuits. ## Panel Integration & Mounting The S00 frame is the smallest in the SIRIUS 3RV6 family: 45 mm wide, 97 mm tall, 96 mm deep. Any mounting position is allowed. Clearance: 50 mm above and below the breaker, 30 mm to the sides, 0 mm forward and backward. Screw terminals accept 2× (0.75 to 2.5 mm²) solid/stranded or 2× 4 mm², torque 0.8 to 1.2 N·m. Relative humidity 10 to 95 % during operation. Shock resistance 25 g / 11 ms per IEC 60068-2-27. Installation altitude up to 2 000 m. RoHS compliance date 05/01/2012 — the part is RoHS-compliant.","metaTitle":"Siemens 3RV6011-1FA10 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-1FA10 SIRIUS motor protection circuit breaker, 5 A rated operational current, Class 10 trip, 690 V, 3-pole, size S00. Active production. Available to order. Request","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"5 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"5 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"65 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"3.5 ... 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dc31762f9ccd3d2d5d5b638c002db63c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621264&mlfb=3RV6011-1FA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1FA10/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RV6011-1FA10?","answer":"The 3RV6011-0CA10 is a functional peer in the same SIRIUS S00 family. The 1FA10 is set to 5 A; the 0CA10 has a different current rating. They share the same frame size, mounting footprint, and terminal layout, so a panel designed for one can accept the other without rewiring — provided the current setting matches the motor load."},{"question":"Where can I buy 3RV6011-1FA10?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for quotation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1FA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1FA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}