{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1FA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1FA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1FA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1FA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RV6011-1FA15 motor protection circuit breaker, S00 frame, 5 A rated operational current, Class 10 thermal-magnetic trip, 690 V AC-3, screw terminals, 45 mm wide, 96 mm deep.","salesMarkdown":"It combines a thermal overload relay (Class 10 trip) and a magnetic short-circuit release in one package, so it protects the motor and the feeder from overload and fault currents without needing a separate overload relay. Rated 5 A at AC-3 and 690 V maximum. The 6 W typical power loss is low enough for tight DIN-rail packing. The 45 mm width and 96 mm depth leave room for a contactor alongside. IEC ratings (690 V, 6 kV surge voltage, 25g shock) support CE marking. The magnetic short-circuit release is fixed (non-adjustable) and set to trip instantaneously on high fault currents — typical for a motor-protective device that must clear a bolted fault before the contactor or upstream breaker sees damage. The 6 kV rated surge voltage resistance (impulse withstand) tells you the insulation coordination is adequate for 400 V systems with standard overvoltage category III. The 10 to 95 % relative humidity rating (non-condensing) is typical for IP20 finger-safe terminals — not for washdown areas. Screw-type terminals on both the main circuit and the auxiliary/control circuit. The main terminals accept 2× (0.5 to 1.5 mm²) solid/stranded or 2× (0.75 to 2.5 mm²) — that is two wires per pole, which is handy for daisy-chaining the supply to a contactor coil. AWG equivalents are 2× (18 to 12) for the mains and 2× (20 to 16) for the aux contacts. Tightening torque is 0.8 to 1.2 N·m — a standard small screwdriver, no torque wrench needed. The auxiliary switch is transverse design, keeping overall depth at 96 mm.","metaTitle":"Siemens 3RV6011-1FA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-1FA15 SIRIUS motor protection circuit breaker, 5 A rated current, Class 10 trip, 690 V AC-3, screw terminals, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"5 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"5 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"65 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"3.5 ... 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/eb48bc168ce902c0793cd77380e7e7c8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621265&mlfb=3RV6011-1FA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1FA15/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does 3RV6011-1FA15 carry?","answer":"RoHS compliance is confirmed with a substance prohibition date of 05/01/2012. The IEC ratings (690 V, 6 kV surge voltage, 25g shock) support CE marking. No UL or CSA listing is explicitly stated in the spec record."},{"question":"Will 3RV6011-1FA15 drop into a panel specified around 3RV6021-4DA10 without rewiring?","answer":"Both are SIRIUS S00 frame breakers with the same 45 mm width and 96 mm depth, so the physical footprint and DIN-rail position are identical. The terminal layout and screw-type termination are the same. The difference is the current rating and trip class — 3RV6021-4DA10 is a higher-current device, so verify the motor FLA matches the breaker setting before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1FA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1FA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}