{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1GA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1GA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1GA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1GA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV6011-1GA10, size S00, 3-pole, 6.3 A rated operational current at AC-3/400 V, Class 10 thermal-magnetic overload release, screw terminals, 45 mm wide, snap-on 35 mm DIN rail.","salesMarkdown":"The Siemens 3RV6011-1GA10 is a SIRIUS motor protection circuit breaker, size S00, designed to protect three-phase motors up to 6.3 A at 400 V AC-3 duty. That AC-3 rating means it's built for switching motor loads under full load — starting and stopping an induction motor, not just resistive heaters. The thermal-magnetic trip combines a Class 10 thermal overload release for motor heating protection and a magnetic short-circuit trip for fast fault clearing. It carries a 690 V maximum rated value across the main circuit, so it's comfortable on 400 V or 480 V systems. The 45 mm width and 96 mm depth fit neatly into a standard motor control center bucket or a small enclosure — you can stack several side-by-side in a 600 mm wide panel. Any mounting position is allowed, so vertical or horizontal orientation in a tight cabinet works fine. Class 10 trip means it will open within 10 seconds at 7.2x the set current, which protects standard squirrel-cage induction motors during locked-rotor conditions. The magnetic short-circuit trip clears fast on a bolted fault, keeping upstream selective coordination intact. Rated impulse withstand voltage of 6 kV gives it decent surge immunity for industrial environments. Power loss is 6 W typical — negligible for thermal budget in a ventilated panel. Screw-type terminals on top and bottom for the main circuit. Accepts two conductors per pole: solid or stranded up to 2x 2.5 mm² or 2x 4 mm², or AWG 2x (18 to 12) and 2x (20 to 16). Finely stranded with ferrules also accepted. Torque range 0.8 to 1.2 N·m — use a torque screwdriver to avoid terminal damage.","metaTitle":"Siemens 3RV6011-1GA10 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-1GA10 SIRIUS motor protection circuit breaker, 6.3 A rated at 400 V AC-3, Class 10 thermal-magnetic trip, 45 mm wide, screw and snap-on DIN rail mounting. Active pr","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"6.3 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"6.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"82 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"4.5 ... 6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8f8a141741c9ea00152dac1ed5ea378a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621266&mlfb=3RV6011-1GA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1GA10/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RV6011-1GA10?","answer":"The 3RV6011-0CA10 is a close functional sibling — same size S00, same 45 mm width, same Class 10 trip and screw terminals. The key difference is the current rating: the -0CA10 is rated at 0.4 to 0.63 A, while the -1GA10 covers 4.5 to 6.3 A. They share the same mounting footprint, so a panel designed for one can accept the other without rewiring, as long as the motor current matches."},{"question":"What compliance documentation does Siemens provide for 3RV6011-1GA10?","answer":"The part is RoHS compliant with a substance prohibition date of May 1, 2012. It carries a 6 kV surge voltage rating per IEC standards, and the shock resistance is tested to 25g / 11 ms per IEC 60068-2-27. Standard Siemens documentation includes a CE declaration and UL/CSA certification for the SIRIUS series."},{"question":"Will 3RV6011-1GA10 drop into a panel specified around 3RV6011-0CA10 without rewiring?","answer":"Yes — both breakers share the same S00 size, 45 mm width, and screw-terminal layout. The mounting hole pattern and DIN rail clip are identical, so the swap is mechanical. Just verify the motor full-load current falls within the 4.5 to 6.3 A range of the -1GA10."},{"question":"Where can I buy 3RV6011-1GA10 and how is it quoted?","answer":"This part is sourced through independent distribution channels. Submit an RFQ for current pricing and availability; lead times and stock positions are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1GA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1GA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}