{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1GA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1GA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1GA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1GA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV6011-1GA15, size S00, 6.3 A rated operational current, Class 10 thermal overload release, 690 V max, screw terminals, 45 mm width.","salesMarkdown":"The Siemens 3RV6011-1GA15 is a SIRIUS motor protection circuit breaker, size S00, rated at 6.3 A operational current with a Class 10 trip characteristic. Rated for 690 V AC at 50/60 Hz, this 3-pole breaker handles motor starting duty (AC-3) at up to 15 switching operations per hour. The 6 W typical power loss stays manageable in a closed panel, and the -20 to +60 °C operating range covers most industrial environments. The 45 mm width and 96 mm depth mean it fits standard S00-size cutouts; clearance requirements are 50 mm upward, 50 mm downward, and 30 mm to the side — no space needed forward or backward. Screw-type terminals on both main and auxiliary circuits accept 2x (0.5 to 1.5 mm²) solid/stranded or 2x (0.75 to 2.5 mm²) with ferrules; AWG equivalents are 2x (18 to 12) for mains and 2x (20 to 16) for auxiliaries. Terminal torque range is 0.8 to 1.2 N·m. RoHS compliance date is May 1, 2012, with substance prohibitance per EU directive. The part carries a 6 kV surge voltage resistance rating and passes 25g / 11 ms shock per IEC 60068-2-27, supporting typical industrial panel certification requirements. The 6.3 A rated operational current and Class 10 trip class are sized for motor protection — Class 10 means the thermal element trips within 10 seconds at 7.2× rated current, matching standard IEC motor starting curves for pumps, fans, and compressors. The magnetic short-circuit release provides instantaneous fault clearing, while the thermal bimetal handles overloads. At 15 AC-3 operations per hour, this breaker is suited for normal motor starting duty, not high-cycle applications like rapid reversing.","metaTitle":"Siemens 3RV6011-1GA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-1GA15 SIRIUS motor protection circuit breaker, 6.3 A rated current, Class 10 trip, 690 V, size S00, screw terminals. Current lifecycle stage. Sourced to order again","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"6 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"6.3 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"6.3 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"82 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","breaking capacity maximum short-circuit current (Icu) at AC at 400 V rated value":"100 kA","breaking capacity operating short-circuit current (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"4.5 ... 6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/39fe8e9e6967fcf4dca89bc3cdaca010.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621267&mlfb=3RV6011-1GA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1GA15/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RV6011-1GA15?","answer":"Submit an RFQ through this listing. The part is sourced through independent distribution channels; availability and current pricing are confirmed at quote time."},{"question":"What is 3RV6011-1GA15's listed depth (96 mm) on this component line?","answer":"The depth is 96 mm, with a width of 45 mm and height of 97 mm. Clearance required: 50 mm above and below, 30 mm to the side, zero forward or backward."},{"question":"Will 3RV6011-1GA15 drop into a panel that was specified around 3RV6011-0CA10 without rewiring?","answer":"Both are size S00 Siemens SIRIUS motor protection breakers with the same 45 mm width and DIN rail mounting, so the mechanical footprint is identical. Terminal layouts are screw-type on both, but verify the 3RV6011-0CA10's current rating against the 6.3 A of this part — the 0CA10 variant carries a different rating and may require recalculation of the motor branch circuit protection."},{"question":"What compliance documentation does this brand provide for 3RV6011-1GA15 (RoHS, REACH, UL, IEC)?","answer":"RoHS compliance is confirmed with a substance prohibitance date of May 1, 2012. The part is designed to IEC 60068-2-27 for shock (25g / 11 ms) and carries a 6 kV surge voltage resistance rating. Standard Siemens SIRIUS documentation includes CE declaration and UL/CSA file numbers available through the manufacturer's support portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1GA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1GA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}