{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1HA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1HA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1HA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1HA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV6011-1HA15, Size S00, 3-pole, 8 A rated, Class 10 trip class, screw terminals, 50/60 Hz.","salesMarkdown":"The Siemens 3RV6011-1HA15 is a SIRIUS motor protection circuit breaker — Size S00, 3-pole, rated 8 A with a Class 10 trip curve, meaning it clears overloads fast enough to protect standard induction motors during start-up without nuisance tripping. Rated operational current is 8 A at up to 690 V AC-3, switching frequency max 15 operations per hour, so it's sized for a typical small motor branch circuit — think conveyors, pumps, or fans in a control panel. Mounts in any position on 35 mm DIN rail (screw or snap-on) per DIN EN 60715, with 45 mm width and 96 mm depth — fits standard S00 footprint in a motor control center or panel. Screw-type terminals on both main and auxiliary circuits accept 2x (0.5 to 2.5 mm²) solid/stranded or 2x (18 to 12 AWG) for the mains, with a tightening torque of 0.8 to 1.2 N·m. Rated for operation from -20 to +60 °C, 10 to 95% relative humidity, with a 6 kV surge voltage withstand — suitable for industrial control panels in unconditioned plant environments. Shock-resistant to 25 g / 11 ms per IEC 60068-2-27; RoHS compliance dated 05/01/2012.","metaTitle":"Siemens 3RV6011-1HA15 SIRIUS Motor Protection CB, 8 A, Class","metaDescription":"Siemens 3RV6011-1HA15 SIRIUS motor protection circuit breaker, 8 A rated, Class 10 trip, Size S00, 3-pole, screw terminals, 50/60 Hz. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"7 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"8 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"8 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"104 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$212.29","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/636d79e3b4ed47381455506d480fff62.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621269&mlfb=3RV6011-1HA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1HA15/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RV6011-1HA15?","answer":"The depth is 96 mm, with a width of 45 mm and height of 97 mm — standard S00 frame size."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1HA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1HA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}