{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6011-1KA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6011-1KA15","canonicalUrl":"https://aoctrl.com/siemens/3RV6011-1KA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1KA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS motor protection circuit breaker, 3RV6011-1KA15, S00 frame, 12.5 A rated operational current, CLASS 10, 690 V AC-3, 45 mm wide, screw and snap-on DIN rail mounting.","salesMarkdown":"The Siemens 3RV6011-1KA15 is a SIRIUS motor protection circuit breaker in the S00 frame, rated 12.5 A operational current with a CLASS 10 trip characteristic. Rated for 690 V at AC-3 duty and 50/60 Hz, this breaker handles motor starting currents up to that voltage class. Mounting position is unrestricted, and the screw-type terminals accept 2×(0.5…1.5 mm²) solid or 2×(0.75…2.5 mm²) stranded — common panel wire sizes. ## S00 frame and panel fit The 3RV6011-1KA15 measures 96 mm deep, 45 mm wide, and 97 mm tall. The any-position mounting means you can orient it vertically or horizontally inside the gland plate area without derating the trip curve. Shock resistance is rated at 25 g for 11 ms per IEC 60068-2-27, and surge voltage withstand is 6 kV — figures that support installation in industrial panels subject to mechanical stress and switching transients. The transverse auxiliary switch design and screw-type terminals for the auxiliary/control circuit match the standard SIRIUS accessory range. If you need to add a remote trip indication or a shunt trip, the same auxiliary blocks that fit the 3RV2 series also fit this S00 frame. Maximum switching frequency at AC-3 is 15 cycles per hour — enough for a pump or fan start once every four minutes, but not for high-cycling applications like a stamping press or rapid-index conveyor. For those, step up to a larger frame or a contactor with a higher rated operating frequency.","metaTitle":"Siemens 3RV6011-1KA15 SIRIUS Motor Protection Circuit Breake","metaDescription":"Siemens 3RV6011-1KA15 SIRIUS motor protection circuit breaker, 12.5 A rated current, CLASS 10 trip class, 690 V AC-3, S00 frame, 45 mm wide. Current lifecycle stage. Quoted on requ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for motor protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"7 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Auxiliary Switch":"transverse","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"12.5 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","For Auxiliary And Control Circuit":"screw-type terminals","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3 at 400 V rated value":"12.5 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"163 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"9 ... 12.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fa4b8b0c02f0b3f607f6bf3634122d5c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621273&mlfb=3RV6011-1KA15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6011-1KA15/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the 3RV6011-1KA15?","answer":"Rated operational current is 12.5 A at AC-3 duty, rated voltage is 690 V, trip class is CLASS 10, and the frame size is S00. It operates at 50/60 Hz and has a typical power loss of 7 W."},{"question":"Will the 3RV6011-1KA15 drop into a panel specified for a 3RV6011-0CA10?","answer":"Both are S00-frame breakers on the same 45 mm DIN-rail footprint, so the mechanical fit is identical. Verify the current rating and trip class on your BOM — the 0CA10 is a different rating variant, not a direct electrical substitute without checking the motor FLA."},{"question":"How do I get current pricing and availability for the 3RV6011-1KA15?","answer":"Submit an RFQ against this order code. Pricing and confirmed availability are quoted at quote time through independent distribution channels; no stock figures or price lists are published here."},{"question":"What compliance documentation does Siemens provide for the 3RV6011-1KA15?","answer":"RoHS compliance is confirmed with a substance prohibition date of 05/01/2012. The part carries shock resistance ratings per IEC 60068-2-27 and surge voltage withstand per IEC standards. Check the manufacturer's declaration for REACH and UKCA if those are required for your market."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6011-1KA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6011-1KA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}