{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6311-1JC10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6311-1JC10","canonicalUrl":"https://aoctrl.com/siemens/3RV6311-1JC10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6311-1JC10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker for starter combinations, 3RV6311-1JC10, size S00, 3-pole, 10 A rated operational current at AC-3 400 V, 690 V insulation voltage, magnetic short-circuit trip 130 A, screw-type terminals, 45 mm width.","salesMarkdown":"It's a 3-pole unit in the compact S00 frame, rated 10 A operational current at AC-3 duty (400 V), which covers the motor-running current for a range of small induction motors up to roughly 4 kW at 400 V three-phase. The magnetic short-circuit trip responds at 130 A, so it clears a bolted fault fast enough to protect the contactor and overload relay downstream — that's the coordination value a panel builder needs for Type 2 coordination. The S00 footprint is 45 mm wide, 97 mm tall, 96 mm deep, with 50 mm clearance needed above and below, and 30 mm at the sides. No forward or backward clearance required, so it tucks tight against the back panel. Screw-type terminals on top and bottom accept 2x (0.75 to 2.5 mm²) solid/stranded or 2x 4 mm²; AWG equivalents are 2x (18 to 12) and 2x (20 to 16). Torque the main contacts to 0.8–1.2 N·m. The 10 A rating at AC-3 400 V is the motor-switching current — that's the figure that determines whether this breaker carries your motor's full-load amps without nuisance tripping during start. The 690 V rated insulation voltage (degree of pollution 3) means it's rated for 690 V line-to-line systems, common in 400 V and 690 V industrial networks. Relative humidity during operation 10–95%. Shock resistance per IEC 60068-2-27: 25g for 11 ms. Installation altitude up to 2000 m above sea level without derating. The substance prohibition date of 05/01/2012 indicates RoHS compliance for that cutoff — the part is RoHS-compliant for the 2012 deadline. Operating frequency at AC-3 is rated at a maximum of 15 switching cycles per hour, which is typical for motor-starting duty.","metaTitle":"Siemens 3RV6311-1JC10 SIRIUS Circuit Breaker, 10 A, 690 V","metaDescription":"Siemens 3RV6311-1JC10 SIRIUS circuit breaker for starter combinations. 10 A rated at AC-3 400 V, 690 V insulation, magnetic short-circuit trip 130 A. S00 size, DIN rail mount. Acti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for starter combinations","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"7 W","Substance Prohibitance (Date)":"05/01/2012","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"10 A","Design Of The Short-Circuit Trip":"magnetic","for AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"10 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"130 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/36a12c53a2a39d292cfc2c64401c949f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621310&mlfb=3RV6311-1JC10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6311-1JC10/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RV6311-1JC10?","answer":"The depth is 96 mm, with 50 mm clearance required above and below, and 30 mm at the sides. No forward or backward clearance needed."},{"question":"Will 3RV6311-1JC10 drop into a panel specified around 3RV6011-0CA10 without rewiring?","answer":"Both are S00 frame size circuit breakers on 35 mm DIN rail with screw-type terminals, so the mechanical fit and wiring method are identical. The 3RV6311-1JC10 is a newer-series variant for starter combinations; the 3RV6011-0CA10 is an older basic motor-protective breaker. Electrical ratings differ — verify the 10 A AC-3 rating and 130 A magnetic trip match your coordination study before swapping."},{"question":"What compliance documentation does Siemens provide for 3RV6311-1JC10?","answer":"The part carries a substance prohibition date of 05/01/2012, indicating RoHS compliance for that deadline. Standard Siemens documentation includes the declaration of conformity (CE), and the product is designed to IEC/EN 60947 standards for circuit breakers. UL/CSA listings are typical for the SIRIUS range but should be confirmed per specific catalog number."},{"question":"Where can I buy 3RV6311-1JC10 and how is it quoted for volume purchases?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for volume or contract pricing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6311-1JC10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6311-1JC10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}