{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6411-0BA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6411-0BA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6411-0BA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6411-0BA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV6411-0BA10, for transformer protection, 0.2 A rated current, Class 10 trip, 690 V, 3-pole, size S00, screw-type terminals, DIN rail mount.","salesMarkdown":"Rated for 690 V at 50/60 Hz, this 3-pole breaker uses a thermal overload release and a magnetic short-circuit trip. The S00 frame size keeps the footprint compact: 45 mm wide, 97 mm tall, 96 mm deep. That 96 mm depth means it sits flush with typical S00 contactors in a motor-starter stack. Screw-type terminals on top and bottom accept 2×(0.75–2.5 mm²) solid/stranded or 2×4 mm², with a tightening torque of 0.8–1.2 N·m. AWG equivalents: 2×(18–12) solid, 2×(20–16) stranded. That covers most control-circuit wiring; for larger transformer secondaries, you'd step up to the S0 frame. Compliance documentation is in order: RoHS compliance date of May 1, 2012 (per EU Directive 2011/65/EU), and the part carries the usual SIRIUS approvals (UL, CSA, CE) for panel builders shipping into North America or Europe.","metaTitle":"Siemens 3RV6411-0BA10 SIRIUS Circuit Breaker, 0.2 A, Class 1","metaDescription":"Siemens 3RV6411-0BA10 SIRIUS circuit breaker for transformer protection, 0.2 A rated current, Class 10 trip, 690 V, 3-pole, S00 size, DIN rail mount. Active production. Sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for transformer protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"5 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.2 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"0.2 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"4.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","breaking capacity maximum short-circuit current (Icu) at AC at 400 V rated value":"100 kA","breaking capacity operating short-circuit current (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.14 ... 0.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/389592ca892ebba6f7052d8cb49d42d0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621322&mlfb=3RV6411-0BA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6411-0BA10/alternatives.json"},"ai":{"faq":[{"question":"Will 3RV6411-0BA10 drop into a panel that was specified around 3RV6011-0CA10 without rewiring?","answer":"Physically, yes — both are S00 size, 45 mm wide, mount on the same 35 mm DIN rail, and use the same screw-terminal layout. No rewiring of the DIN rail or terminal positions is needed. But the overload curve is different: the 3RV6411-0BA10 is for transformer primary protection, not motor protection. If the original panel was a motor starter, the 3RV6411-0BA10 will trip incorrectly on motor inrush."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6411-0BA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6411-0BA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}