{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6411-0DA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6411-0DA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6411-0DA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6411-0DA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV6411-0DA10, for transformer protection, 3-pole, 0.32 A, CLASS 10, 690 V, screw terminals, S00 size, snap-on 35 mm DIN rail.","salesMarkdown":"## What this SIRIUS breaker does Rated operational current is 0.32 A at AC-3 duty (400 V), with a maximum rated voltage of 690 V. This means it protects the transformer primary against sustained overloads and short circuits, tripping fast enough (CLASS 10) to prevent winding damage while ignoring harmless inrush. The S00 frame size keeps the footprint compact: 45 mm wide, 97 mm tall, 96 mm deep. That 45 mm width is the same as a standard single-pole MCB footprint, so it slots into a crowded DIN rail without re-spacing.","metaTitle":"Siemens SIRIUS 3RV6411-0DA10 Circuit Breaker, 0.32 A, CLASS","metaDescription":"Siemens SIRIUS 3RV6411-0DA10 circuit breaker for transformer protection, 0.32 A rated current, CLASS 10 trip, 690 V max, 3-pole, screw terminals, snap-on 35 mm DIN rail. Sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for transformer protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"5 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.32 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"0.32 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"6.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","breaking capacity maximum short-circuit current (Icu) at AC at 400 V rated value":"100 kA","breaking capacity operating short-circuit current (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.22 ... 0.32 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/10241233f1aa3b8a417cff92c655dfd6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621324&mlfb=3RV6411-0DA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6411-0DA10/alternatives.json"},"ai":{"faq":[{"question":"Will 3RV6411-0DA10 drop into a panel specified around 3RV6021-4DA10 without rewiring?","answer":"Both are S00 frame size and mount on 35 mm DIN rail, so the mechanical fit is the same. However, the 3RV6411-0DA10 is rated 0.32 A for transformer protection, while the 3RV6021-4DA10 is a motor-protective breaker with a different trip curve. Check the load current and protection requirements before swapping — the terminals are screw-type on both."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6411-0DA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6411-0DA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}