{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6411-0EA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6411-0EA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6411-0EA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6411-0EA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker, 3RV6411-0EA10, for transformer protection, 0.4 A rated current, Class 10, 690 V, 50-60 Hz, size S00, screw-type terminals, DIN rail snap-on.","salesMarkdown":"The Siemens 3RV6411-0EA10 is a SIRIUS circuit breaker designed specifically for transformer protection, rated 0.4 A operational current at AC-3 / 400 V, with a thermal overload release (Class 10) and a magnetic short-circuit trip. It handles up to 690 V at 50-60 Hz, making it a fit for small transformer primaries in control panels and machine feeders where inrush must not nuisance-trip the breaker. Screw-type terminals on top and bottom accept 2x (0.75 to 2.5 mm²) solid/stranded or 2x (0.5 to 1.5 mm²) finely stranded with ferrules; torque to 0.8–1.2 N·m. Operates from -20 to +60 °C ambient, with 10–95 % relative humidity non-condensing. Shock resistance per IEC 60068-2-27: 25 g / 11 ms. Installation altitude up to 2000 m. Total typical power loss is 5 W.","metaTitle":"Siemens 3RV6411-0EA10 SIRIUS Circuit Breaker, 0.4 A, Class 1","metaDescription":"Siemens 3RV6411-0EA10 SIRIUS circuit breaker for transformer protection, 0.4 A rated current, Class 10 trip, 690 V, 50-60 Hz, size S00, DIN rail mount. Current production. Sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for transformer protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"5 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.4 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"0.4 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"8.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","breaking capacity maximum short-circuit current (Icu) at AC at 400 V rated value":"100 kA","breaking capacity operating short-circuit current (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.28 ... 0.4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/837a077724aba3a10cbda5c63c43486f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621325&mlfb=3RV6411-0EA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6411-0EA10/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to 3RV6411-0EA10?","answer":"The 3RV6011-0CA10 is a peer in the same SIRIUS family, but it is a standard motor-protective circuit breaker, not specifically designed for transformer protection. The 3RV6411-0EA10's thermal and magnetic settings are tuned for transformer inrush; swapping without verifying coordination may cause nuisance tripping or loss of protection."},{"question":"Will 3RV6411-0EA10 drop into a panel specified around 3RV6011-0CA10 without rewiring?","answer":"Both are size S00, same 45 mm width and DIN-rail footprint, so the mechanical fit and terminal layout are identical. No rewiring needed for the panel cutout or rail. However, the protection curve differs — confirm the transformer's inrush characteristic against the Class 10 trip before committing."},{"question":"How do I get current pricing and availability for 3RV6411-0EA10?","answer":"Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Siemens provide for 3RV6411-0EA10?","answer":"The part has a substance prohibition date of 05/01/2012 (RoHS / REACH compliance) and a rated surge voltage resistance of 6 kV. Standard Siemens declarations of conformity and material declarations are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6411-0EA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6411-0EA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}