{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RV6411-0FA10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RV6411-0FA10","canonicalUrl":"https://aoctrl.com/siemens/3RV6411-0FA10","factsUrl":"https://aoctrl.com/api/mcp/products/3RV6411-0FA10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS circuit breaker for transformer protection, 3RV6411-0FA10, 0.5 A rated, Class 10 trip, 690 V, 3-pole, S00 frame, screw terminals, 45 mm wide.","salesMarkdown":"The Siemens SIRIUS 3RV6411-0FA10 is a 3-pole circuit breaker sized for transformer protection, rated at 0.5 A operational current with a Class 10 trip characteristic. It's built on the S00 frame, which keeps the width at 45 mm, so it fits neatly into a standard DIN-rail panel alongside other SIRIUS motor starters and breakers. The S00 frame gives you 45 mm width, 97 mm height, 96 mm depth — that's a compact footprint for a 3-pole breaker. Wiring clearance: 50 mm above and below, 30 mm at the sides, 0 mm front and back. Main circuit terminals accept 2×(0.75–2.5 mm²) solid/stranded or 2×4 mm², with a tightening torque of 0.8–1.2 N·m. That's a standard screwdriver range, nothing exotic. ## Environment and approvals Relative humidity 10–95 %. Shock resistance 25g / 11 ms per IEC 60068-2-27. Installation altitude up to 2000 m. The part is RoHS compliant as of the substance prohibitance date 05/01/2012 — so it meets the current EU RoHS directive.","metaTitle":"Siemens SIRIUS 3RV6411-0FA10 Circuit Breaker, 0.5 A, Class 1","metaDescription":"Siemens SIRIUS 3RV6411-0FA10 circuit breaker for transformer protection. 0.5 A rated, Class 10 trip, 690 V, S00 frame. Active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Protection Circuit Breakers (MPCB)"],"specifications":{"Depth":"96 mm","Width":"45 mm","Height":"97 mm","Upwards":"50 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"50 mm","Trip Class":"CLASS 10","At The Side":"30 mm","Rated Value":"690 V","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715","Mounting Position":"any","Solid Or Stranded":"2x (0,75 ... 2,5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Product Designation":"Circuit breaker","Design Of The Product":"for transformer protection","For Main Current Circuit":"screw-type terminals","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","power loss [W] total typical":"5 W","Substance Prohibitance (Date)":"05/01/2012","Design Of The Overload Release":"thermal","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"0.5 A","at AWG cables for main contacts":"2x (18 to 12), 2x (20 to 16)","Design Of The Short-Circuit Trip":"magnetic","Relative Humidity During Operation":"10 ... 95 %","operating frequency at AC-3 maximum":"15 1/h","Surge Voltage Resistance Rated Value":"6 kV","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","shock resistance according to IEC 60068-2-27":"25g / 11 ms","operational current at AC-3 at 400 V rated value":"0.5 A","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value":"100 kA","operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value":"100 kA","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=621326&mlfb=3RV6411-0FA10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RV6411-0FA10/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RV6411-0FA10 and how do I get a price?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is 3RV6411-0FA10's rated current and trip class?","answer":"Rated operational current is 0.5 A (AC-3 at 400 V), with a Class 10 trip characteristic. That means it trips within 10 seconds at 7.2× rated current."},{"question":"Will 3RV6411-0FA10 drop into a panel specified around 3RV6011-0CA10?","answer":"Both are S00-frame 3-pole breakers on 45 mm width, so they share the same DIN-rail footprint and terminal spacing. The main difference is the trip class and current rating — verify your overload protection settings when swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RV6411-0FA10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RV6411-0FA10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}