{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW3013-1BB04","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW3013-1BB04","canonicalUrl":"https://aoctrl.com/siemens/3RW3013-1BB04","factsUrl":"https://aoctrl.com/api/mcp/products/3RW3013-1BB04","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW3013-1BB04 soft starter, size S00, 3.6 A at 40 °C, 24 V AC/50-60 Hz control, screw terminals, integrated bypass.","salesMarkdown":"## Siemens 3RW3013-1BB04 SIRIUS Soft Starter — Size S00, 3.6 A, Integrated Bypass The Siemens 3RW3013-1BB04 is a SIRIUS soft starter in frame size S00, rated 3.6 A at 40 °C with a 24 V control supply at 50/60 Hz. It includes an integrated bypass contact system, meaning the thyristors are shorted after start-up for reduced heat dissipation and longer service life — a feature that matters when the starter runs continuously, as on a conveyor or pump. Clearance: 60 mm above, 40 mm below, 15 mm at the sides. The vertical mounting surface allows ±10° rotation and ±10° tilt front-to-back. Rated insulation voltage is 600 V, pollution degree 3 per IEC 60947-4-2. Derating begins at 40 °C: 3.3 A at 50 °C, 3.0 A at 60 °C. Main current circuit and auxiliary/control circuit both use screw-type terminals. Solid conductor range: 2x (0.25... 2.5 mm²). Auxiliary contacts: 2x (20... 14 AWG). Front clamping point accepts 2x (16... 10 AWG). Maximum wire length to the motor is 300 m. ## Protection and Diagnostics No built-in motor overload protection or intrinsic device protection — external overload relay required. No adjustable current limitation. Minimum load is 10% of rated current. Fault signal displayed via a red LED. No external reset input. Not suitable for inside-delta circuit wiring. No motor brake output.","metaTitle":"Siemens 3RW3013-1BB04 SIRIUS Soft Starter, 3.6A, 24V, Size S","metaDescription":"Siemens 3RW3013-1BB04 SIRIUS soft starter, 3.6A at 40°C, 24V control, size S00, integrated bypass. Current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"150mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45mm","title":"3RW3013-1BB04","Height":"95mm","Upwards":"60mm","Downwards":"40mm","Thyristors":"Yes","At The Side":"15mm","description":"SIRIUS soft starter S00 3.6 A, 1.5 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Screw terminals","During Storage":"-40 ... +80°C","External Reset":"No","lifecycle_stage":"current","During Operation":"-25 ... +60°C","Fastening Method":"screw and snap-on mounting","Minimum Load [%]":"10%","Mounting Position":"With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","Product Designation":"Soft starter","Wire Length Maximum":"300m","Derating Temperature":"40°C","Inside-Delta Circuit":"No","at 50 Hz rated value":"24V","at 60 Hz rated value":"24V","at 40 °C rated value":"3.6A","at 50 °C rated value":"3.3A","at 60 °C rated value":"3A","For Auxiliary Contacts":"2x (20 ... 14)","For Main Current Circuit":"screw-type terminals","Motor Overload Protection":"No","Intrinsic Device Protection":"No","Adjustable Current Limitation":"No","Size Of Engine Control Device":"S00","Insulation Voltage Rated Value":"600V","Using The Front Clamping Point":"2x (16 ... 10)","Operating Frequency Rated Value":"50 ... 60Hz","Display Version For Fault Signal":"red","Integrated Bypass Contact System":"Yes","For Auxiliary And Control Circuit":"screw-type terminals","Product Component Motor Brake Output":"No","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","reference code according to EN 61346-2":"Q","during operation according to IEC 60721":"3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Evaluation Of Thermistor Motor Protection":"No","at standard circuit at 40 °C rated value":"1.5kW","at standard circuit at 50 °C rated value":"1.5hp","control supply voltage 1 at DC rated value":"24V","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Control Supply Voltage Frequency 1 Rated Value":"50Hz","Control Supply Voltage Frequency 2 Rated Value":"60Hz","Installation Altitude At Height Above Sea Level":"5 000m","continuous operating current [% of Ie] at 40 °C":"115%","Operating Voltage At Standard Circuit Rated Value":"200 ... 480V","contact rating of auxiliary contacts according to UL":"B300 / R300","Relative Negative Tolerance Of The Operating Frequency":"-10%","Relative Positive Tolerance Of The Operating Frequency":"10%","For Auxiliary Contacts Finely Stranded With Core End Processing":"2x (20 ... 16)","relative negative tolerance of the control supply voltage at DC":"-20%","relative positive tolerance of the control supply voltage at DC":"20%","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10%","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10%","Relative Negative Tolerance Of The Operating Voltage At Standard Circuit":"-15%","Relative Positive Tolerance Of The Operating Voltage At Standard Circuit":"10%","power loss [W] at operational current at 40 °C during operation typical":"0.25W","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15%","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15%","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10%","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10%"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$178.16","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/12e5c5fa12ec9670a04ac3249da76a1e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=207338&mlfb=3RW3013-1BB04"},"ai":{"faq":[{"question":"What is the depth of 3RW3013-1BB04?","answer":"The depth is 150 mm. Width is 45 mm, height is 95 mm."},{"question":"What is the rated current of 3RW3013-1BB04?","answer":"Rated current is 3.6 A at 40 °C, derating to 3.3 A at 50 °C and 3.0 A at 60 °C. Control voltage is 24 V AC at 50/60 Hz."},{"question":"Does 3RW3013-1BB04 have an integrated bypass?","answer":"Yes, it includes an integrated bypass contact system that shorts the thyristors after start-up for reduced heat dissipation."},{"question":"Where can I buy 3RW3013-1BB04?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW3013-1BB04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW3013-1BB04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}