{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW4423-3BC36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW4423-3BC36","canonicalUrl":"https://aoctrl.com/siemens/3RW4423-3BC36","factsUrl":"https://aoctrl.com/api/mcp/products/3RW4423-3BC36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS soft starter, 3RW4423-3BC36, 62 A at 40 °C, 690 V insulation voltage, integrated bypass.","salesMarkdown":"It uses thyristor technology and includes an integrated bypass contact system, which means the bypass contactor carries the full-load current after the start, reducing heat dissipation in the soft starter during continuous operation. The 62 A rating applies at 40 °C ambient. The derating temperature threshold is 40 °C, so no reduction is needed below that. ## Motor protection and control features The minimum load is 8% of the rating, which covers small pumps and fans. The inside-delta circuit configuration is supported, which reduces the soft starter current rating to 58% of the motor FLA for delta-connected motors — a common wiring scheme to downsize the starter. Screw fixing is the fastening method. Clearance distances: 100 mm upward, 75 mm downward, 5 mm at the sides. Main current circuit uses box terminals accepting stranded 2x (4 to 50 mm²) or solid 2x (0.25 to 1.5 mm²). Auxiliary and control circuits use spring-loaded terminals for 2x (24 to 16 AWG). Maximum wire length to the motor is 500 m. The operating frequency is 50 to 60 Hz.","metaTitle":"Siemens 3RW4423-3BC36 SIRIUS Soft Starter, 62 A at 40 °C","metaDescription":"Siemens SIRIUS 3RW4423-3BC36 soft starter, 62 A rated at 40 °C, 690 V insulation voltage, with integrated bypass and adjustable current limitation. Current production, sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Soft Starters"],"specifications":{"Depth":"270mm","Solid":"2x (0.25 ... 1.5 mm²)","Width":"170mm","title":"3RW4423-3BC36","Height":"192mm","Upwards":"100mm","Stranded":"2x (4 ... 50 mm²)","Downwards":"75mm","Thyristors":"Yes","At The Side":"5mm","description":"SIRIUS soft starter Values at 575 V, 50 °C standard: 32 A, 25 hp Inside-delta: 55 A, 50 hp 400-690 V AC, 115 V AC spring-type terminals!!! Phased-out product!!! Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5524-3HA16<<","During Storage":"-25 ... +80°C","External Reset":"Yes","lifecycle_stage":"current","During Operation":"60°C","Fastening Method":"screw fixing","Minimum Load [%]":"8%","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","Product Designation":"Soft starter","Wire Length Maximum":"500m","Derating Temperature":"40°C","Inside-Delta Circuit":"Yes","at 50 Hz rated value":"115V","at 60 Hz rated value":"115V","at 40 °C rated value":"62A","at 50 °C rated value":"55A","at 60 °C rated value":"50A","For Auxiliary Contacts":"2x (24 ... 16)","For Main Current Circuit":"box terminal","Motor Overload Protection":"Yes","Using Both Clamping Points":"2x (10 ... 1/0)","Intrinsic Device Protection":"Yes","Adjustable Current Limitation":"Yes","Using The Back Clamping Point":"10 ... 2/0","Insulation Voltage Rated Value":"690V","Using The Front Clamping Point":"10 ... 2/0","Operating Frequency Rated Value":"50 ... 60Hz","Display Version For Fault Signal":"Display","Integrated Bypass Contact System":"Yes","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Component Motor Brake Output":"Yes","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","reference code according to EN 61346-2":"Q","during operation according to IEC 60721":"3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Evaluation Of Thermistor Motor Protection":"Yes","at standard circuit at 40 °C rated value":"22kW","at standard circuit at 50 °C rated value":"25hp","Finely Stranded Without Core End Processing":"2x (4 ... 35 mm²)","number of CO contacts for auxiliary contacts":"1","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"3","Type Of Voltage Of The Control Supply Voltage":"AC","at inside-delta circuit at 40 °C rated value":"37kW","at inside-delta circuit at 50 °C rated value":"50hp","Control Supply Voltage Frequency 1 Rated Value":"50Hz","Control Supply Voltage Frequency 2 Rated Value":"60Hz","Installation Altitude At Height Above Sea Level":"5 000m","continuous operating current [% of Ie] at 40 °C":"115%","Operating Voltage At Standard Circuit Rated Value":"400 ... 690V","at 690 V at standard circuit at 40 °C rated value":"37kW","contact rating of auxiliary contacts according to UL":"B300 / R300","Operating Voltage At Inside-Delta Circuit Rated Value":"400 ... 600V","Relative Negative Tolerance Of The Operating Frequency":"-10%","Relative Positive Tolerance Of The Operating Frequency":"10%","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10%","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10%","Relative Negative Tolerance Of The Operating Voltage At Standard Circuit":"-15%","Relative Positive Tolerance Of The Operating Voltage At Standard Circuit":"10%","power loss [W] at operational current at 40 °C during operation typical":"10W","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15%","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15%","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10%","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10%","Adjustable Motor Current For Motor Overload Protection Minimum Rated Value":"7A","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15%","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10%"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,116.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b29bb0531caa6a02c8f28b5abf2d7ec6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=39877&mlfb=3RW4423-3BC36"},"ai":{"faq":[{"question":"What are the key ratings for this soft starter?","answer":"Rated 62 A at 40 °C, derating to 55 A at 50 °C and 50 A at 60 °C. Insulation voltage 690 V. Operating frequency 50/60 Hz. Control supply 115 V at both frequencies. Integrated bypass and adjustable current limitation."},{"question":"What wiring terminals does it use?","answer":"Main circuit uses box terminals for stranded 2x (4 to 50 mm²) or solid 2x (0.25 to 1.5 mm²). Auxiliary and control circuits use spring-loaded terminals for 2x (24 to 16 AWG)."},{"question":"What clearance distances are required around the unit?","answer":"100 mm upward, 75 mm downward, and 5 mm at the sides for proper ventilation and access."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW4423-3BC36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW4423-3BC36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}