{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW4426-1BC46","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW4426-1BC46","canonicalUrl":"https://aoctrl.com/siemens/3RW4426-1BC46","factsUrl":"https://aoctrl.com/api/mcp/products/3RW4426-1BC46","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW4426-1BC46 soft starter, 133 A at 40 °C, 690 V insulation voltage, integrated bypass contact system, inside-delta circuit capable, screw-type terminals.","salesMarkdown":"## 133 A at 40 °C — the current that drives the panel placement The 3RW4426-1BC46: That 40 °C figure is the baseline for sizing the soft starter against the motor full-load current; if the panel ambient runs hotter, the usable current drops accordingly. The soft starter only conducts during start/stop; the bypass carries the full-load current in steady state. Inside-delta circuit capability means the soft starter can be wired in the delta legs of a delta-connected motor, reducing the current rating required from the soft starter to 58% of the motor FLA. Confirm the motor winding configuration before specifying this wiring method. ## Mounting and terminal specs for the panel build Dimensions are 270 mm deep, 170 mm wide, 192 mm high. The mounting position allows vertical surface with ±90° rotation and ±22.5° tilt front-to-back, giving flexibility in tight enclosures. Screw fixing is the fastening method. Clearance requirements: 100 mm upwards, 75 mm downwards, 5 mm at the sides. These are the minimum air gaps for cooling airflow and arc flash containment — respect them in the gland plate layout. Maximum wire length to the motor is 500 m. ## Active production — sourcing for the BOM line No stock-holding claim is made; each order is validated per the build schedule. ## Protection and control features for the motor circuit Motor overload protection and intrinsic device protection are both integrated. Adjustable current limitation lets the starting current be set between 0 and the rated value, protecting both the motor and the driven load during acceleration. Minimum load is 8% of the soft starter rating — below this the motor current may not be reliably detected. The display provides fault signal readout for diagnostics. External reset is supported for remote restart after a trip. Degree of pollution 3 per IEC 60947-4-2 means the unit is rated for conductive pollution environments typical in industrial panels without climate control.","metaTitle":"Siemens 3RW4426-1BC46 SIRIUS Soft Starter, 133 A at 40 °C","metaDescription":"Siemens 3RW4426-1BC46 SIRIUS soft starter, 133 A at 40 °C, 690 V insulation, integrated bypass. Active production, quoted to order. RFQ for availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"270 mm","Width":"170 mm","Height":"192 mm","Mounting":"screw fixing","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4510bbae6107a27837b890adc1b2fe4f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=390313&mlfb=3RW4426-1BC46","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW4426-1BC46/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW4426-1BC46","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW4426-1BC46 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}