{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW4435-6BC46","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW4435-6BC46","canonicalUrl":"https://aoctrl.com/siemens/3RW4435-6BC46","factsUrl":"https://aoctrl.com/api/mcp/products/3RW4435-6BC46","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW4435-6BC46 soft starter, 232 A at 40 °C, 690 V insulation voltage, 50/60 Hz, screw fixing, 170 x 200 x 270 mm (W x H x D).","salesMarkdown":"## 232 A at 40 °C — current derating and load matching The 3RW4435-6BC46: The 40 °C figure is the reference — if your panel ambient runs higher, the continuous current drops linearly; budget the actual load against the derated value, not the headline number. Inside-delta wiring is supported, which lets the soft starter handle roughly 58% of the motor FLA compared to in-line connection — useful for retrofitting into a panel where the existing contactor and overload are staying in the main circuit. Minimum load is 8% of the rated current — below that the thyristor firing angle may not hold conduction. Verify the motor no-load current exceeds this threshold, especially on small or lightly coupled loads. ## Panel footprint and wiring terminals Dimensions are 170 mm wide, 200 mm high, 270 mm deep — the depth is the dimension that drives enclosure depth selection. Main circuit termination accepts stranded 25–120 mm² or busbar connection; auxiliary contacts take solid 0.5–2.5 mm² or finely stranded 16–95 mm². The main lug range covers 4–250 kcmil — common for the 232 A class. Clearance at the side is 5 mm; upward clearance 100 mm, downward 75 mm — respect these for airflow and cable bending radius. ## Protection and control features Built-in motor overload protection and intrinsic device protection are included — no separate overload relay needed for most applications. Adjustable current limitation lets you set the starting current between 0 and the rated value, which helps on generators or weak supply networks. External reset input is present, so the soft starter can be reset from a remote pushbutton or PLC output without opening the panel door. Fault signal is displayed on the unit — no separate display module required for basic diagnostics. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments with conductive pollution — no additional conformal coating needed in most panel conditions. Insulation voltage rated 690 V, operating frequency 50/60 Hz, thyristor-based design. The maximum motor cable length is 500 m — beyond that, reflected wave effects on the motor winding should be evaluated.","metaTitle":"Siemens 3RW4435-6BC46 SIRIUS Soft Starter, 232 A at 40 °C","metaDescription":"Siemens 3RW4435-6BC46 SIRIUS soft starter, 232 A at 40 °C, 690 V insulation, inside-delta capable. Active production, quoted to order. RFQ for volume pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"270 mm","Width":"170 mm","Height":"200 mm","Mounting":"screw fixing","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f89ffce4f2f6fe59921696f7c1996831.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=277626&mlfb=3RW4435-6BC46","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW4435-6BC46/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW4435-6BC46","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW4435-6BC46 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}