{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW4436-2BC45","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW4436-2BC45","canonicalUrl":"https://aoctrl.com/siemens/3RW4436-2BC45","factsUrl":"https://aoctrl.com/api/mcp/products/3RW4436-2BC45","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW4436-2BC45 soft starter, 281 A at 40 °C, 690 V insulation voltage, 50/60 Hz, thyristor-based, adjustable current limitation, inside-delta circuit, screw fixing, 270 mm depth.","salesMarkdown":"## Rated current and thermal derating — what 281 A means on the panel The 3RW4436-2BC45: Thyristor-based output with adjustable current limitation lets you set the start ramp peak below the motor's locked-rotor draw, reducing mechanical shock on the load train. The inside-delta circuit configuration means the soft starter can be wired in the motor delta loop, reducing the unit's current rating requirement compared to in-line connection. ## Mounting and connection — screw-fixed, multi-cable entry Mounting position allows vertical surface with ±90° rotation and ±22.5° tilt front/back — fits into tight panel layouts where the gland plate orientation is fixed. Fastening method is screw fixing, not DIN rail snap-on, so plan for drilled holes and M6 or M8 hardware. Main current circuit accepts busbar connection or cable: stranded 25–120 mm², finely stranded 16–95 mm², or AWG 4–250 kcmil. The front and back clamping points each handle 6–2/0 AWG; using both clamping points maxes at 2x 1/0 AWG. Clearance spaces: 100 mm upwards, 75 mm downwards, 5 mm at the side — essential for airflow and cable bending radius. Maximum wire length to the motor is 500 m; longer runs increase voltage drop and may cause nuisance overcurrent trips during start. ## Protection and diagnostics — built-in overload and fault display Motor overload protection is integrated, so a separate thermal overload relay is not needed for most installations. Intrinsic device protection (thyristor overtemperature, phase imbalance) is also included, reducing external monitoring hardware. Fault signal is shown on a display (not just a single LED), giving a readable code for troubleshooting — useful when the panel is remote from the operator station. External reset input allows remote clearing after a fault, avoiding a trip to the cabinet. Minimum load is 8% of the rated current — below that the soft starter may not detect the motor current correctly, so verify the no-load or light-load condition. Compliance documentation includes IEC 60947-4-2 (pollution degree 3), operating frequency 50/60 Hz, and storage temperature range -25 to +80 °C.","metaTitle":"Siemens 3RW4436-2BC45 SIRIUS Soft Starter, 281 A, 690 V","metaDescription":"Siemens 3RW4436-2BC45 SIRIUS soft starter, 281 A at 40°C, 690 V insulation voltage, thyristor-based, adjustable current limitation, inside-delta circuit","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"270 mm","Width":"170 mm","Height":"200 mm","Mounting":"screw fixing","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0ede2bc1a831405662537cf896a58342.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=532066&mlfb=3RW4436-2BC45","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW4436-2BC45/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW4436-2BC45","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW4436-2BC45 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}