{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW4453-6BC45","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW4453-6BC45","canonicalUrl":"https://aoctrl.com/siemens/3RW4453-6BC45","factsUrl":"https://aoctrl.com/api/mcp/products/3RW4453-6BC45","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW4453-6BC45 soft starter, 954 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, inside-delta circuit, screw fixing.","salesMarkdown":"## 954 A at 40 °C — motor sizing anchor The 3RW4453-6BC45 is rated 954 A at 40 °C ambient. Derating starts above 40 °C, so if your enclosure runs hot, size on the 50 °C or 60 °C column, not the 40 °C figure. Insulation voltage is 690 V rated, covering 400 V, 480 V, and 690 V line-to-line systems. Operating frequency is 50/60 Hz — one unit handles both, no separate variant for 60 Hz markets. ## Integrated bypass and inside-delta — panel space savings This soft starter has an integrated bypass contact system. That means once the motor reaches full speed, the thyristors are shorted out — no external bypass contactor to wire in, no extra heat dissipation from the SCRs during run. The inside-delta circuit reduces the current through each thyristor by about 42% compared to standard in-line connection, so for a given motor current the unit can be smaller than an equivalent in-line soft starter. ## Wiring and connection — main and control circuits Main current circuit connects via busbar — typical for this current class. Acceptable cable sizes: stranded 70-240 mm², finely stranded 50-240 mm², or AWG 2/0-500 kcmil. For auxiliary and control circuits, screw-type terminals accepting solid 0.5-2.5 mm² or 20-14 AWG. Maximum motor cable length is 500 m — beyond that, voltage drop and reflected wave issues may require output reactors. The unit includes a display for fault signals and supports external reset, so you can clear faults remotely without opening the panel door. ## Protection and diagnostics — built-in, no add-ons needed Motor overload protection is integrated — no separate overload relay required. Intrinsic device protection covers overtemperature, overcurrent, and phase-loss on the thyristor stack. Adjustable current limitation lets you set the start current between the minimum load of 8% and the unit's rated current, protecting both motor and driven load during ramp-up. The unit includes a motor brake output — useful for holding loads at standstill without a separate brake contactor. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments with conductive dust or occasional condensation — no derating needed for typical factory floor conditions.","metaTitle":"Siemens 3RW4453-6BC45 SIRIUS Soft Starter, 954A","metaDescription":"Siemens 3RW4453-6BC45 SIRIUS soft starter, rated 954 A at 40 °C. Active production, integrated bypass, inside-delta circuit. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"290 mm","Width":"510 mm","Height":"640 mm","Mounting":"screw fixing","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ba5f635e0e5325493e4e4afebda49b67.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=101239&mlfb=3RW4453-6BC45","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW4453-6BC45/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW4453-6BC45","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW4453-6BC45 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}