{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW4458-2BC36","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW4458-2BC36","canonicalUrl":"https://aoctrl.com/siemens/3RW4458-2BC36","factsUrl":"https://aoctrl.com/api/mcp/products/3RW4458-2BC36","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW4458-2BC36 soft starter, 1680 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, screw fixing.","salesMarkdown":"## 1680 A at 40 °C — the rating that decides panel fit The 3RW4458-2BC36: That 40 °C figure is the baseline for sizing the panel ventilation and the upstream feeder — if the enclosure ambient runs hotter, the available motor current drops by roughly 12 % per 10 °C rise. ## Mounting and wiring — what the enclosure needs Mounting is screw fixing with a vertical surface orientation; the unit can be rotated ±90° or tilted ±22.5° front/back. Dimensions are 510 mm wide × 640 mm high × 290 mm deep — that's a large-frame soft starter, so the enclosure depth needs to clear the 290 mm plus cable bending radius. Main circuit connection is via busbar (stranded 70–240 mm² or 2/0–500 kcmil). The main lugs are sized for high-current cable — plan for compression lugs and a torque wrench. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides. The 500 m maximum wire length to the motor matters for long cable runs — voltage drop and reflected wave effects need checking at that distance. ## Protection and control features Built-in motor overload protection and intrinsic device protection are standard. Adjustable current limitation lets you set the start current between 8 % and 100 % of the rated current — useful for soft-starting conveyors or pumps without tripping upstream breakers. Supports inside-delta connection for six-wire motors, which reduces the line current draw during start. An external reset input and a display for fault signals are included — the display shows the trip code so you don't need a separate HMI to diagnose a jam. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments with conductive dust or occasional condensation — no derating needed for typical factory-floor conditions.","metaTitle":"Siemens 3RW4458-2BC36 SIRIUS Soft Starter, 1680 A","metaDescription":"Siemens SIRIUS 3RW4458-2BC36 soft starter, 1680 A at 40 °C, 690 V insulation, 50/60 Hz. Current production. Quoted to order against BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"290 mm","Width":"510 mm","Height":"640 mm","Mounting":"screw fixing","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/035ebd0dcad0e8575977c4950ba35029.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=220623&mlfb=3RW4458-2BC36","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW4458-2BC36/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW4458-2BC36","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW4458-2BC36 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}