{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5074-2TB05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5074-2TB05","canonicalUrl":"https://aoctrl.com/siemens/3RW5074-2TB05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5074-2TB05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5074-2TB05 soft starter, 135 A minimum, 200-600 V, ATEX, IECEx, CE, UL, CSA, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, screw fixing.","salesMarkdown":"## Active production, ATEX-rated motor starting The 3RW5074-2TB05: Rated for a minimum motor FLA of 135 A at a line voltage range of 200 to 600 V, this frame covers the majority of low-voltage induction motors in pump, fan, and compressor duty across 50/60 Hz networks. ## Trip class and starting profiles per IEC 60947-4-2 The soft starter offers selectable trip classes CLASS 10A, 10E (preset), and 20E in accordance with IEC 60947-4-2. CLASS 20E extends the window for high-inertia starts where acceleration time exceeds 10 seconds. Built-in voltage ramp and pump ramp down profiles let you tailor the start and stop to the load: voltage ramp reduces inrush torque on conveyors or crushers; pump ramp down eliminates pressure surges on discharge lines during stop. ## Fieldbus and network integration The base unit supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — no separate communication module needed for most plant-floor networks. PROFIenergy is available when paired with the PROFINET standard communication module, allowing energy-management data collection during idle phases. Remote reset is achieved by cycling the 24 V DC control supply voltage — no fieldbus command required for a simple restart after a fault clears. The error logbook function is available only with special accessories; factor that into commissioning if event-logging is required. ## Mounting and thermal derating Screw fixing on a vertical mounting surface, rotatable ±90° and tiltable ±22.5° front-to-back. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 0 mm backwards, 5 mm at the sides. The 230 x 282 x 160 mm envelope fits standard 600 mm deep enclosures with room for top-entry cables. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if potential contact lifting is a concern.","metaTitle":"Siemens 3RW5074-2TB05 Soft Starter, 135 A Min, 200-600 V","metaDescription":"Siemens 3RW5074-2TB05 soft starter in active production. Rated 135 A minimum, 200-600 V, ATEX/IECEx/UL/CSA approved. Quoted to order against BOM quantities.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"282 mm","Width":"160 mm","Height":"230 mm","Mounting":"screw fixing","Trip Class":"CLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2","Product Status":"Active","Service Factor":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/99b1af31c3c010f1fa3634fef98b9a15.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830763&mlfb=3RW5074-2TB05","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW5074-2TB05/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5074-2TB05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5074-2TB05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}