{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5074-6AB15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5074-6AB15","canonicalUrl":"https://aoctrl.com/siemens/3RW5074-6AB15","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5074-6AB15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5074-6AB15 soft starter, hybrid switching device, 135 A minimum, 200-600 V rated, Trip Class 10A/10E/20E, ATEX, UKEX, IECEx, CE, UL, CSA.","salesMarkdown":"## Hybrid switching with ATEX and fieldbus The Siemens 3RW5074-6AB15 is a hybrid switching device in the soft starter category, rated for a minimum load current of 135 A and a rated voltage of 200 to 600 V. It carries ATEX, UKEX, and IECEx certifications alongside CE, UL, and CSA — meaning it can be specified into Zone 2 gas or dust areas in a hot-strip mill without a separate isolation barrier. The Trip Class is configurable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2 — this determines how long the starter can sustain the motor start current before tripping. CLASS 10A is tight for high-inertia loads; 20E gives the thermal budget for a long ramp on a centrifuge or crusher. ## Fieldbus and analog output for tension control The 3RW5074-6AB15 integrates with PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP — so it can slot into a mill control network without a protocol gateway. The analog output defaults to 4-20 mA and can be parameterized to 0-10 V via the High Feature HMI, which is useful for feeding a torque or current signal to a downstream tension controller. Soft Torque, Voltage Ramp, and Pump Ramp Down are built in — the pump ramp down reduces water hammer on a discharge line by extending the deceleration ramp, which matters when the starter is feeding a 135 A motor on a mill coolant pump. ## Mounting clearances and ambient derating The unit is screw-fixed, 160 mm wide, 230 mm high, 282 mm deep. Required clearances: 100 mm upward, 75 mm downward, 10 mm forward, 5 mm at the side, 0 mm backward. In a panel near a furnace, the ambient derating kicks in at 40 °C — above that the 135 A minimum must be recalculated per the derating curve. Shock resistance is 15 g for 11 ms, with potential contact lifting from 12 g / 11 ms — this is relevant for mounting on a mill foundation where vibration from the rolling stands couples into the panel. ## Lifecycle and procurement The ATEX, UKEX, and IECEx certifications are listed on the nameplate — the documentation package (RoHS, REACH, UL, IEC) should be requested at quote to satisfy the quality-doc-control gate.","metaTitle":"Siemens 3RW5074-6AB15 Soft Starter, 135 A, 200-600 V, ATEX","metaDescription":"Siemens 3RW5074-6AB15 soft starter, 135 A minimum, rated 200-600 V, Trip Class 10A/10E/20E. ATEX, UKEX, IECEx, CE, UL, CSA approved. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"282 mm","Width":"160 mm","Height":"230 mm","Mounting":"screw fixing","Trip Class":"CLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2","Product Status":"Active","Service Factor":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fd661eb409758d8ffb0ab2815d9a206c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830769&mlfb=3RW5074-6AB15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW5074-6AB15/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5074-6AB15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5074-6AB15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}