{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5074-6TB15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5074-6TB15","canonicalUrl":"https://aoctrl.com/siemens/3RW5074-6TB15","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5074-6TB15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5074-6TB15 soft starter, 135 A minimum, 200-600 V, ATEX, IECEx, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, Class 10A/10E/20E, active production.","salesMarkdown":"## What does the ATEX and IECEx certification mean for this soft starter? The 3RW5074-6TB15 carries ATEX and IECEx certification, meaning it is approved for use in potentially explosive atmospheres — not just the starter itself, but the motor circuit it controls, when installed per the relevant standards. This is a differentiator from standard soft starters that lack hazardous-area approval; if your line runs in a Zone 1 or Zone 2 gas environment, or a Zone 21/22 dust environment, this part meets the certification requirement without needing an external isolation barrier. ## What is the operating window and how does it govern motor fit? Rated for a minimum 135 A at 200-600 V, the 3RW5074-6TB15 covers medium-to-large induction motors in the 75-150 kW range depending on line voltage and duty cycle — the 135 A floor is the lowest continuous current you can set, so the motor full-load current must be at or above that. ## Lifecycle and compliance — still in active production It carries UL, CSA, and CE marking, so it is accepted in North American and European panels without additional agency review for the starter itself. Dimensions are 282 mm deep, 160 mm wide, 230 mm high — this is a screw-fixed device, not a DIN-rail snap-on, so plan for four mounting holes on the back panel and leave the specified clearances: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the sides. Mounting position is flexible — the unit can be rotated ±90° on a vertical surface and tilted ±22.5° forward or backward, which helps when fitting into existing enclosures with non-ideal mounting planes. ## Fieldbus and control features Built-in support for PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP means this starter can be dropped into most common industrial networks without an external gateway — the fieldbus interface is integrated, not an add-on module. It includes voltage ramp, soft torque, and pump ramp-down profiles — the pump ramp-down is specifically useful for preventing water hammer in pumping applications, while soft torque helps with high-friction loads like conveyors. Remote reset is available by cycling the control supply voltage — useful for unattended restart after a fault, though the auto-reset function is also present if the application allows automatic re-start.","metaTitle":"Siemens 3RW5074-6TB15 Soft Starter, 135 A, 200-600 V, ATEX","metaDescription":"Siemens 3RW5074-6TB15 soft starter, rated 135 A at 200-600 V, ATEX/IECEx certified, active production. UL, CSA, CE. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"282 mm","IECEx":"Yes","Width":"160 mm","title":"3RW5074-6TB15","Height":"230 mm","Minimum":"135 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 315 A, 110-250 V AC Screw terminals Thermistor input","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Voltage Ramp":"Yes","Analog Output":"No","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"315 A","at 50 °C rated value":"279 A","at 60 °C rated value":"255 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"36 W","at 50 °C after startup":"29 W","at 60 °C after startup":"24 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"0","Number Of Digital Inputs":"1","Weight Without Packaging":"7.3 kg","at 40 °C during startup":"3 368 W","at 50 °C during startup":"2 805 W","at 60 °C during startup":"2 455 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"2","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Substance Prohibitance (Date)":"09/23/2019","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS01","Insulation Voltage Rated Value":"600 V","Ramp-Down Time Of Soft Starter":"0 ... 20 s","at 230 V at 40 °C rated value":"90 kW","at 400 V at 40 °C rated value":"160 kW","at 500 V at 40 °C rated value":"200 kW","Width Of Connection Bar Maximum":"35 mm; with connection cover 3RT1966-4EA1 maximum length 45 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"75 hp","at 220/230 V at 50 °C rated value":"100 hp","at 460/480 V at 50 °C rated value":"200 hp","at 575/600 V at 50 °C rated value":"250 hp","of circuit breaker usable at 400 V":"3VA2440-7MN32-0AA0; Type of assignment 1, Iq = 65 kA","of circuit breaker usable at 500 V":"3VA2440-7MN32-0AA0; Type of assignment 1, Iq = 65 kA","at the digital inputs at AC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","of line contactor usable up to 480 V":"3RT1075","of line contactor usable up to 690 V":"3RT1075","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","accuracy class according to IEC 61557-12":"5 %","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"124 ... 210 lbf·in","At Rotary Coding Switch On Switch Position 1":"135 A","At Rotary Coding Switch On Switch Position 2":"147 A","At Rotary Coding Switch On Switch Position 3":"159 A","At Rotary Coding Switch On Switch Position 4":"171 A","At Rotary Coding Switch On Switch Position 5":"183 A","At Rotary Coding Switch On Switch Position 6":"195 A","At Rotary Coding Switch On Switch Position 7":"207 A","At Rotary Coding Switch On Switch Position 8":"219 A","At Rotary Coding Switch On Switch Position 9":"231 A","at AWG cables for main current circuit solid":"2/0 ... 500 kcmil","for DIN cable lug for main contacts stranded":"50 ... 240 mm²","At Rotary Coding Switch On Switch Position 10":"243 A","At Rotary Coding Switch On Switch Position 11":"255 A","At Rotary Coding Switch On Switch Position 12":"267 A","At Rotary Coding Switch On Switch Position 13":"279 A","At Rotary Coding Switch On Switch Position 14":"291 A","At Rotary Coding Switch On Switch Position 15":"303 A","At Rotary Coding Switch On Switch Position 16":"315 A","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"105 mA","utilization category according to IEC 60947-4-2":"AC-53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","for DIN cable lug for main contacts finely stranded":"70 ... 240 mm²","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; derating as of 1000 m, see Manual","Locked-Rotor Current At Close Of Bypass Contact Maximum":"2.2 A","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"min. 2x 70 mm², max. 2x 240 mm²","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"min. 2x 70 mm², max. 2x 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"120 ... 240 mm²","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3 335; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"95 ... 300 mm²","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"120 ... 240 mm²","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1 333-2; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"95 ... 300 mm²","at AWG cables for main contacts for box terminal using the back clamping point":"250 ... 500 kcmil","at AWG cables for main contacts for box terminal using the front clamping point":"3/0 ... 600 kcmil","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded Without Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"70 ... 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded Without Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded Without Core End Processing":"70 ... 240 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/872c17d2f5e0fba9285916f4e687fb9a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830773&mlfb=3RW5074-6TB15"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5074-6TB15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5074-6TB15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}