{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5075-6AB05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5075-6AB05","canonicalUrl":"https://aoctrl.com/siemens/3RW5075-6AB05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5075-6AB05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5075-6AB05 soft starter, 160 A minimum rated current, 200-600 VAC, ATEX and IECEx certified, Trip Class 10A/10E/20E, with PROFIBUS, Modbus RTU/TCP, and EtherNet/IP.","salesMarkdown":"## What this 160 A soft starter brings to a motor control panel The Siemens 3RW5075-6AB05 is a hybrid soft starter from the SIRIUS family, rated for a minimum motor current of 160 A and a supply voltage range of 200 to 600 VAC. It carries ATEX and IECEx certification, meaning it is approved for use in explosive atmospheres — a requirement that narrows the field of suitable soft starters considerably. The Trip Class is preset to CLASS 10A or 10E, with CLASS 20E also selectable per IEC 60947-4-2, so it matches motor protection curves for standard and heavy-start applications. This unit supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP natively, plus PROFINET with the standard communication module. That fieldbus flexibility means it slots into most existing control architectures without a gateway. The analog output is configurable as 4-20 mA or 0-10 V, settable via the High Feature HMI accessory. Mounting is screw-fixed to a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. The enclosure dimensions are 230 mm high, 160 mm wide, and 282 mm deep — plan the panel depth accordingly. Screw-fixing to a vertical mounting surface is the standard method. The unit is rotatable ±90° and tiltable ±22.5° front-to-back, which helps when fitting into a crowded enclosure. Minimum clearances: 100 mm upwards, 10 mm forwards, 75 mm downwards, 5 mm at the sides — respect those for airflow and cable bending radius. The control supply is 24 VDC. Remote reset is achieved by cycling the control supply voltage off and on. The minimum load is 15% of the smallest settable Ie, so light-load applications may need a bypass contactor to avoid nuisance tripping. Shock resistance is rated at 15 g / 11 ms, dropping to 12 g / 11 ms if potential contact lifting is a concern. The service factor is 1 — no overload margin beyond nameplate rating.","metaTitle":"Siemens 3RW5075-6AB05 Soft Starter, 160 A, ATEX, 200-600 V","metaDescription":"Siemens 3RW5075-6AB05 soft starter, 160 A minimum, 200-600 VAC, ATEX/IECEx certified, Trip Class 10A/10E/20E. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"282 mm","Width":"160 mm","Height":"230 mm","Mounting":"screw fixing","Trip Class":"CLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2","Product Status":"Active","Service Factor":"1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/509a28a3a56c1ade0c9985b34e7ba3a0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830783&mlfb=3RW5075-6AB05","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW5075-6AB05/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5075-6AB05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5075-6AB05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}