{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5075-6TB05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5075-6TB05","canonicalUrl":"https://aoctrl.com/siemens/3RW5075-6TB05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5075-6TB05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5075-6TB05 SIRIUS soft starter, 160 A minimum, 200-600 V rated voltage, ATEX, IECEx, UL, CSA, CE, Trip Class 10A/10E/20E, PROFIBUS, PROFINET, Modbus RTU/TCP, EtherNet/IP, 282 mm depth, 160 mm width, 230 mm height.","salesMarkdown":"## 160 A minimum — the motor size floor The 3RW5075-6TB05: The 160 A minimum rating sets the smallest motor this soft starter can handle. For a 400 V line, that's roughly an 90 kW motor at full load; at 230 V, about 45 kW. If your BOM motor is smaller, this unit is oversized and you'll lose the soft-start benefit — the current threshold won't engage properly. Rated voltage spans 200 to 600 V, covering 208 V North American, 400 V European, and 480/600 V industrial lines in one order code. No voltage-tap selection needed. ## Trip Class selection for motor protection Trip Class 10A, 10E, or 20E per IEC 60947-4-2 — the preset is 10A/10E, which clears a locked-rotor condition in 10 seconds at 7.2× FLA. The class is field-selectable via the HMI or parameter set. ## ATEX and IECEx — hazardous-area motor starting ATEX and IECEx certified — this soft starter can control motors in Zone 1 or Zone 2 gas atmospheres and Zone 21 or Zone 22 dust atmospheres when installed in the appropriate enclosure. The certification covers the soft starter itself, not the motor; the motor must also carry its own ATEX rating for the zone. UL and CSA approvals plus CE marking cover North American and European installations. No separate variant needed for UL 508 or CSA C22.2 panels. ## Fieldbus integration — five protocols on one unit PROFIBUS, PROFINET, Modbus RTU, Modbus TCP, and EtherNet/IP — all supported natively or via the standard communication module. The PROFINET interface also supports PROFIenergy for energy management during idle phases. No gateway needed for most plant networks. ## Soft-start features for pump and conveyor duty Voltage ramp and soft torque let you tune the acceleration profile. Pump ramp down decelerates gradually to prevent water hammer in pipeline systems. The minimum load is 15% of the smallest settable Ie — below that, the soft starter may not detect the motor current reliably. Auto-reset and remote reset by cycling the control supply are standard. No separate reset relay needed for unattended restart after a fault. ## Mounting and panel clearances Screw fixing to a vertical mounting surface; the unit can be rotated ±90° or tilted ±22.5° front-to-back. Minimum clearances: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, 0 mm backwards. These are the ventilation and cable-bend allowances — ignore them and you'll derate the unit or trap heat. ## Operating temperature and derating Rated for -25 to +60 °C during operation, but derating applies above 40 °C. At 50 °C ambient, expect roughly 80% of the rated current; at 60 °C, about 60%. The derating curve is in the manual — factor it into the panel thermal design, especially if the soft starter shares an enclosure with other heat sources.","metaTitle":"Siemens 3RW5075-6TB05 Soft Starter, 160 A, 200-600 V, ATEX","metaDescription":"Siemens 3RW5075-6TB05 soft starter, 160 A minimum, 200-600 V rated voltage, ATEX and IECEx certified. Active production, multi-protocol fieldbus.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"282 mm","IECEx":"Yes","Width":"160 mm","title":"3RW5075-6TB05","Height":"230 mm","Minimum":"160 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 370 A, 24 V AC/DC Screw terminals Thermistor input","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Voltage Ramp":"Yes","Analog Output":"No","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"370 A","at 50 °C rated value":"328 A","at 60 °C rated value":"300 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"36 W","at 50 °C after startup":"29 W","at 60 °C after startup":"24 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"0","Number Of Digital Inputs":"1","Weight Without Packaging":"7.3 kg","at 40 °C during startup":"3 726 W","at 50 °C during startup":"3 124 W","at 60 °C during startup":"2 748 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"2","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Substance Prohibitance (Date)":"09/23/2019","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS01","Insulation Voltage Rated Value":"600 V","Ramp-Down Time Of Soft Starter":"0 ... 20 s","at 230 V at 40 °C rated value":"110 kW","at 400 V at 40 °C rated value":"200 kW","at 500 V at 40 °C rated value":"250 kW","Width Of Connection Bar Maximum":"35 mm; with connection cover 3RT1966-4EA1 maximum length 45 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"100 hp","at 220/230 V at 50 °C rated value":"125 hp","at 460/480 V at 50 °C rated value":"250 hp","at 575/600 V at 50 °C rated value":"300 hp","of circuit breaker usable at 400 V":"3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA","of circuit breaker usable at 500 V":"3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA","at the digital inputs at AC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","of line contactor usable up to 480 V":"3RT1075","of line contactor usable up to 690 V":"3RT1075","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","accuracy class according to IEC 61557-12":"5 %","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"124 ... 210 lbf·in","At Rotary Coding Switch On Switch Position 1":"160 A","At Rotary Coding Switch On Switch Position 2":"174 A","At Rotary Coding Switch On Switch Position 3":"188 A","At Rotary Coding Switch On Switch Position 4":"202 A","At Rotary Coding Switch On Switch Position 5":"216 A","At Rotary Coding Switch On Switch Position 6":"230 A","At Rotary Coding Switch On Switch Position 7":"244 A","At Rotary Coding Switch On Switch Position 8":"258 A","At Rotary Coding Switch On Switch Position 9":"272 A","at AWG cables for main current circuit solid":"2/0 ... 500 kcmil","for DIN cable lug for main contacts stranded":"50 ... 240 mm²","At Rotary Coding Switch On Switch Position 10":"286 A","At Rotary Coding Switch On Switch Position 11":"300 A","At Rotary Coding Switch On Switch Position 12":"314 A","At Rotary Coding Switch On Switch Position 13":"328 A","At Rotary Coding Switch On Switch Position 14":"342 A","At Rotary Coding Switch On Switch Position 15":"356 A","At Rotary Coding Switch On Switch Position 16":"370 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"490 mA","utilization category according to IEC 60947-4-2":"AC-53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","for DIN cable lug for main contacts finely stranded":"70 ... 240 mm²","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; derating as of 1000 m, see Manual","Locked-Rotor Current At Close Of Bypass Contact Maximum":"7.6 A","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"min. 2x 70 mm², max. 2x 240 mm²","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"min. 2x 70 mm², max. 2x 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"120 ... 240 mm²","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3 336; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"95 ... 300 mm²","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"120 ... 240 mm²","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1 334-2; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"95 ... 300 mm²","at AWG cables for main contacts for box terminal using the back clamping point":"250 ... 500 kcmil","at AWG cables for main contacts for box terminal using the front clamping point":"3/0 ... 600 kcmil","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded Without Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"70 ... 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded Without Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded Without Core End Processing":"70 ... 240 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/acf7e7ca3bcebf3e184fa01a8c326293.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830787&mlfb=3RW5075-6TB05"},"ai":{"faq":[{"question":"What is 3RW5075-6TB05's listed ATEX certification?","answer":"The ATEX certification is Yes, and it also carries IECEx certification. This means the soft starter is approved for use in potentially explosive atmospheres when installed per the manufacturer's instructions and in a suitable enclosure."},{"question":"What compliance documentation does Siemens provide for 3RW5075-6TB05?","answer":"The unit carries UL approval, CSA approval, and CE marking. These cover North American and European regulatory requirements. ATEX and IECEx certificates are also available for hazardous-area installations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5075-6TB05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5075-6TB05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}