{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5077-2TB15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5077-2TB15","canonicalUrl":"https://aoctrl.com/siemens/3RW5077-2TB15","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5077-2TB15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5077-2TB15 SIRIUS soft starter, 240 A minimum, 200-600 V rated, ATEX/IECEx, UL/CSA, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, Trip Class 10A/10E/20E, voltage ramp and pump ramp down, 282 x 160 x 230 mm.","salesMarkdown":"## Ratings that govern the motor start The 3RW5077-2TB15: Minimum set current is 240 A — that's the floor for the overload setting, not the motor FLA. Trip class is selectable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2, which defines the maximum allowable stall time before the soft starter trips — 10A for fast starts (e.g., centrifugal pumps), 20E for high-inertia loads like crushers or conveyors. ## Fieldbus and motor protection options Onboard PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP mean this starter integrates directly into most common automation networks without an external gateway. PROFIenergy is supported when paired with the PROFINET communication module, enabling energy-saving standby modes during production pauses. The starter offers voltage ramp, soft torque, and pump ramp down — the latter reduces water hammer on pump stops by gradually reducing torque rather than cutting power abruptly. Remote reset is available by cycling the control supply voltage. ## Mounting and environmental fit Dimensions are 282 mm deep, 160 mm wide, 230 mm high — screw fixing to a vertical panel. The mounting position allows +/-90° rotation and +/-22.5° tilt front-to-back, giving flexibility in tight cabinets. Operating ambient is -25 to +60 °C, but the datasheet notes derating above 40 °C — factor this into the enclosure thermal budget. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if contact lifting is a concern. ## Approvals for hazardous and ordinary locations ATEX and IECEx certified (both marked Yes), meaning this soft starter can be installed in Zone 2 / Zone 22 gas and dust atmospheres when paired with appropriate upstream protection. Also carries CE, UL, and CSA marks — covers most global panel specs without a second variant.","metaTitle":"Siemens 3RW5077-2TB15 Soft Starter, 240 A, 200-600 V, ATEX","metaDescription":"Siemens 3RW5077-2TB15 soft starter, 240 A minimum, 200-600 V rated, ATEX/IECEx, UL/CSA, PROFIBUS/Modbus/EtherNet/IP, Trip Class 10A/10E/20E.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"282 mm","IECEx":"Yes","Width":"160 mm","title":"3RW5077-2TB15","Height":"230 mm","Minimum":"240 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 570 A, 110-250 V AC Spring-loaded terminals Thermistor input","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Voltage Ramp":"Yes","Analog Output":"No","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"570 A","at 50 °C rated value":"504 A","at 60 °C rated value":"460 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"73 W","at 50 °C after startup":"57 W","at 60 °C after startup":"47 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"0","Number Of Digital Inputs":"1","Weight Without Packaging":"7.3 kg","at 40 °C during startup":"7 019 W","at 50 °C during startup":"5 801 W","at 60 °C during startup":"5 048 W","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"2","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Substance Prohibitance (Date)":"09/23/2019","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS01","Insulation Voltage Rated Value":"600 V","Ramp-Down Time Of Soft Starter":"0 ... 20 s","at 230 V at 40 °C rated value":"160 kW","at 400 V at 40 °C rated value":"315 kW","at 500 V at 40 °C rated value":"355 kW","Width Of Connection Bar Maximum":"35 mm; with connection cover 3RT1966-4EA1 maximum length 45 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"150 hp","at 220/230 V at 50 °C rated value":"200 hp","at 460/480 V at 50 °C rated value":"400 hp","at 575/600 V at 50 °C rated value":"500 hp","of circuit breaker usable at 400 V":"3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA","of circuit breaker usable at 500 V":"3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA","at the digital inputs at AC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","of line contactor usable up to 480 V":"3TF68","of line contactor usable up to 690 V":"3TF68","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","accuracy class according to IEC 61557-12":"5 %","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"124 ... 210 lbf·in","At Rotary Coding Switch On Switch Position 1":"240 A","At Rotary Coding Switch On Switch Position 2":"262 A","At Rotary Coding Switch On Switch Position 3":"284 A","At Rotary Coding Switch On Switch Position 4":"306 A","At Rotary Coding Switch On Switch Position 5":"328 A","At Rotary Coding Switch On Switch Position 6":"350 A","At Rotary Coding Switch On Switch Position 7":"372 A","At Rotary Coding Switch On Switch Position 8":"394 A","At Rotary Coding Switch On Switch Position 9":"416 A","at AWG cables for main current circuit solid":"2/0 ... 500 kcmil","for DIN cable lug for main contacts stranded":"50 ... 240 mm²","At Rotary Coding Switch On Switch Position 10":"438 A","At Rotary Coding Switch On Switch Position 11":"460 A","At Rotary Coding Switch On Switch Position 12":"482 A","At Rotary Coding Switch On Switch Position 13":"504 A","At Rotary Coding Switch On Switch Position 14":"526 A","At Rotary Coding Switch On Switch Position 15":"548 A","At Rotary Coding Switch On Switch Position 16":"570 A","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"105 mA","utilization category according to IEC 60947-4-2":"AC-53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","for DIN cable lug for main contacts finely stranded":"70 ... 240 mm²","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; derating as of 1000 m, see Manual","Locked-Rotor Current At Close Of Bypass Contact Maximum":"2.2 A","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"min. 2x 70 mm², max. 2x 240 mm²","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"min. 2x 70 mm², max. 2x 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"120 ... 240 mm²","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3 340-8; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"95 ... 300 mm²","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"120 ... 240 mm²","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1 437-2; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"95 ... 300 mm²","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","at AWG cables for main contacts for box terminal using the back clamping point":"250 ... 500 kcmil","at AWG cables for main contacts for box terminal using the front clamping point":"3/0 ... 600 kcmil","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded Without Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"70 ... 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded Without Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded Without Core End Processing":"70 ... 240 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/45af105e9d41cad35a91de987fa2e8b3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830813&mlfb=3RW5077-2TB15"},"ai":{"faq":[{"question":"What is the ATEX rating on this soft starter?","answer":"ATEX is marked Yes, along with IECEx, CE, UL, and CSA. This qualifies it for installation in hazardous areas per the ATEX directive, provided the rest of the system meets the zone requirements."},{"question":"What compliance documentation does Siemens provide for the 3RW5077-2TB15?","answer":"CE marking is standard; UL and CSA approvals are listed. ATEX and IECEx certificates are also available. RoHS and REACH declarations are typically included in the product documentation pack from Siemens."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5077-2TB15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5077-2TB15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}