{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5077-6AB04","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5077-6AB04","canonicalUrl":"https://aoctrl.com/siemens/3RW5077-6AB04","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5077-6AB04","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5077-6AB04 soft starter, 240 A minimum, 200-480 V, ATEX/UKEX/IECEx certified, Trip Class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP/PROFINET.","salesMarkdown":"## Hazardous-area motor starting with ATEX traceability The 3RW5077-6AB04 carries ATEX, UKEX, and IECEx certification, making it suitable for soft-starting motors in Zone 1/2 gas or Zone 21/22 dust environments when installed per the system certificate. The 240 A minimum current rating defines the lower bound of the motor FLA it can protect — size up from this floor, not down. Operating range spans 200 to 480 V, covering 208 V, 230 V, 400 V, and 480 V networks common in industrial plants globally. The Trip Class is configurable as CLASS 10A, 10E (preset), or 20E per IEC 60947-4-2, which sets the maximum thermal memory during start — CLASS 10A limits heating for frequent starts, while CLASS 20E allows longer acceleration for high-inertia loads. ## Fieldbus integration and commissioning constraints This soft starter supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET simultaneously — no protocol adapter needed for multi-vendor control architectures. PROFIenergy is available when paired with the PROFINET communication module, enabling energy-proportional load shedding during idle periods. Screw fixing is the specified fastening method — no DIN-rail clip, so allocate tool access for M5 or equivalent hardware. Clearance requirements: 100 mm upward, 75 mm downward, 10 mm forward, 0 mm backward, 5 mm at the side. These are the minimum air gaps for heat dissipation and cable bending radius — violating them derates the 60 °C ambient ceiling. ## Lifecycle status and global approvals Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms with potential contact lifting, which matters for shipboard or mobile equipment installations. ## Application-specific starting modes Voltage Ramp and Soft Torque are both available — Soft Torque reduces the initial torque spike for belt-driven loads or conveyors where mechanical shock must be limited. Pump Ramp Down provides a controlled deceleration to prevent water hammer in pump stations, extending the life of check valves and pipe supports. Analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI parameterization. Remote reset is supported by cycling the control supply voltage, and auto-reset is available for unattended restart after a fault clears — both reduce service calls on remote installations. Minimum load is 15% of the smallest settable Ie, meaning the starter will not regulate below that threshold — motors drawing less than 15% of the current setting may not start reliably. The error logbook function requires special accessories and is not available in the base configuration.","metaTitle":"Siemens 3RW5077-6AB04 Soft Starter, 240 A, 200-480 V, ATEX","metaDescription":"Siemens 3RW5077-6AB04 soft starter, 240 A minimum, 200-480 V, ATEX/UKEX/IECEx certified, Trip Class 10A/10E/20E. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","UKEX":"Yes","Depth":"282 mm","IECEx":"Yes","Width":"160 mm","title":"3RW5077-6AB04","Height":"230 mm","Minimum":"240 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 480 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 570 A, 24 V AC/DC Screw terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"570 A","at 50 °C rated value":"504 A","at 60 °C rated value":"460 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"73 W","at 50 °C after startup":"57 W","at 60 °C after startup":"47 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"7.3 kg","at 40 °C during startup":"7 019 W","at 50 °C during startup":"5 801 W","at 60 °C during startup":"5 048 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"2","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Substance Prohibitance (Date)":"09/23/2019","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS01","Insulation Voltage Rated Value":"600 V","Ramp-Down Time Of Soft Starter":"0 ... 20 s","at 230 V at 40 °C rated value":"160 kW","at 400 V at 40 °C rated value":"315 kW","Width Of Connection Bar Maximum":"35 mm; with connection cover 3RT1966-4EA1 maximum length 45 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"150 hp","at 220/230 V at 50 °C rated value":"200 hp","at 460/480 V at 50 °C rated value":"400 hp","of circuit breaker usable at 400 V":"3VA2580-6HN32-0AA0 ; Type of assignment 1, Iq = 65 kA","of circuit breaker usable at 500 V":"3VA2580-6HN32-0AA0 ; Type of assignment 1, Iq = 65 kA","at the digital inputs at AC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","of line contactor usable up to 480 V":"3TF68","of line contactor usable up to 690 V":"3TF68","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","accuracy class according to IEC 61557-12":"5 %","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"124 ... 210 lbf·in","At Rotary Coding Switch On Switch Position 1":"240 A","At Rotary Coding Switch On Switch Position 2":"262 A","At Rotary Coding Switch On Switch Position 3":"284 A","At Rotary Coding Switch On Switch Position 4":"306 A","At Rotary Coding Switch On Switch Position 5":"328 A","At Rotary Coding Switch On Switch Position 6":"350 A","At Rotary Coding Switch On Switch Position 7":"372 A","At Rotary Coding Switch On Switch Position 8":"394 A","At Rotary Coding Switch On Switch Position 9":"416 A","at AWG cables for main current circuit solid":"2/0 ... 500 kcmil","for DIN cable lug for main contacts stranded":"50 ... 240 mm²","At Rotary Coding Switch On Switch Position 10":"438 A","At Rotary Coding Switch On Switch Position 11":"460 A","At Rotary Coding Switch On Switch Position 12":"482 A","At Rotary Coding Switch On Switch Position 13":"504 A","At Rotary Coding Switch On Switch Position 14":"526 A","At Rotary Coding Switch On Switch Position 15":"548 A","At Rotary Coding Switch On Switch Position 16":"570 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Holding Current In Bypass Operation Rated Value":"490 mA","utilization category according to IEC 60947-4-2":"AC-53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","for DIN cable lug for main contacts finely stranded":"70 ... 240 mm²","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","Inrush Current By Closing The Bypass Contacts Maximum":"7.6 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; derating as of 1000 m, see Manual","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"min. 2x 70 mm², max. 2x 240 mm²","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"min. 2x 70 mm², max. 2x 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"120 ... 240 mm²","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3 340-8 ; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"95 ... 300 mm²","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"120 ... 240 mm²","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1 437-2 ; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"95 ... 300 mm²","at AWG cables for main contacts for box terminal using the back clamping point":"250 ... 500 kcmil","at AWG cables for main contacts for box terminal using the front clamping point":"3/0 ... 600 kcmil","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded Without Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"70 ... 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded Without Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded Without Core End Processing":"70 ... 240 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e1c8b6cd662f19c35b10fbead1eb606f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830814&mlfb=3RW5077-6AB04"},"ai":{"faq":[{"question":"What ATEX certification does the 3RW5077-6AB04 carry?","answer":"ATEX certification is listed as Yes, along with UKEX and IECEx. This qualifies the soft starter for installation in potentially explosive atmospheres when integrated per the system certificate and applicable installation standards."},{"question":"What fieldbus protocols does the 3RW5077-6AB04 support?","answer":"It supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET simultaneously. PROFIenergy is available when used with the PROFINET communication module."},{"question":"What are the clearance requirements for mounting the 3RW5077-6AB04?","answer":"Minimum clearances: 100 mm upward, 75 mm downward, 10 mm forward, 0 mm backward, and 5 mm at the side. These gaps ensure adequate airflow for the -25 to +60 °C operating range with derating above 40 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5077-6AB04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5077-6AB04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}