{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5077-6AB05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5077-6AB05","canonicalUrl":"https://aoctrl.com/siemens/3RW5077-6AB05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5077-6AB05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5077-6AB05 soft starter, 240 A minimum, 200-600 V rated voltage, ATEX, IECEx, UL, CSA, CE, PROFIBUS, PROFINET, Modbus RTU/TCP, EtherNet/IP, 282 mm depth, 160 mm width, 230 mm height.","salesMarkdown":"## Rated current and voltage envelope The 3RW5077-6AB05 is a Siemens SIRIUS soft starter rated for a minimum operating current of 240 A across a 200-600 V supply range. The trip class is configurable as CLASS 10A, 10E (preset), or 20E per IEC 60947-4-2. ## Hazardous-area and global approvals ATEX and IECEx certification are listed on this variant — the soft starter may be installed in Zone 2 or Zone 22 gas/dust atmospheres, per the equipment group and temperature class on the nameplate. This is a distinguishing feature: not all 3RW5 frame sizes carry ATEX, so the -6AB05 suffix confirms the hazardous-area rating. UL, CSA, and CE marking are all present, covering North American and European installation codes. For a tender submission or panel build destined for a CE-marked machine, the CE declaration of conformity is available from Siemens per the standard documentation package. ## Fieldbus and control interface The base unit supports PROFIBUS, PROFINET (standard), Modbus RTU, Modbus TCP, and EtherNet/IP — all listed as native, not requiring an external gateway module. This covers the three dominant industrial Ethernet protocols plus the legacy fieldbus, so the starter slots into a Siemens S7-1500 environment or a Rockwell ControlLogix network without a protocol converter. PROFIenergy is supported when paired with the PROFINET communication module, enabling energy-management profiles during idle phases — relevant for pump and fan applications where the motor coasts between cycles. The analog output is configurable as 4-20 mA (default) or 0-10 V, parameterizable via the High Feature HMI. This feeds motor current or power data to a PLC analog input or a local panel meter without a separate transducer. ## Mounting and thermal derating Mounting is screw-fix to a vertical surface, with ±90° rotation and ±22.5° tilt forward/backward allowed. Clearance requirements: 100 mm upward, 75 mm downward, 10 mm forward, 0 mm backward, 5 mm at the sides. The 0 mm backward clearance means the unit can sit flush against the back panel, saving depth in a shallow enclosure. For a panel build in a non-conditioned enclosure, the internal ambient rise must be calculated against the 40 °C threshold — at 50 °C ambient, expect a current derating of approximately 1.5% per °C above 40 °C, though the exact curve is in the Siemens manual. Physical dimensions: 282 mm depth, 160 mm width, 230 mm height. The width fits a standard 160 mm DIN-rail footprint, but note the fastening method is screw-fix, not snap-on — the unit bolts to the mounting plate. ## Starting modes and load protection Voltage ramp and soft torque are both available — voltage ramp is the standard soft-start profile, while soft torque applies a current-limiting ramp that reduces mechanical shock on belt-driven or gear-coupled loads. Pump ramp down is also listed, which extends the deceleration time to prevent water hammer in pump applications. Torque control is not available on this unit — if the application requires closed-loop torque regulation during start (e.g., for tension control), a different SIRIUS variant or a VFD would be needed. Auto-reset and remote reset (by cycling the 24 V DC control supply) are both supported, allowing the starter to re-crank after a fault without a manual panel visit — useful for remote pumping stations. ## Lifecycle and sourcing posture No stock-holding claim is made; the supply posture is per-RFQ confirmation.","metaTitle":"Siemens 3RW5077-6AB05 Soft Starter, 240 A, 200-600 V, ATEX","metaDescription":"Siemens 3RW5077-6AB05 soft starter, 240 A minimum, 200-600 V rated voltage, ATEX and IECEx certified. Active production, sourced per RFQ. UL, CSA, CE approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"282 mm","IECEx":"Yes","Width":"160 mm","title":"3RW5077-6AB05","Height":"230 mm","Minimum":"240 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 570 A, 24 V AC/DC Screw terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"570 A","at 50 °C rated value":"504 A","at 60 °C rated value":"460 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"73 W","at 50 °C after startup":"57 W","at 60 °C after startup":"47 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"7.3 kg","at 40 °C during startup":"7 019 W","at 50 °C during startup":"5 801 W","at 60 °C during startup":"5 048 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"2","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Substance Prohibitance (Date)":"09/23/2019","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS01","Insulation Voltage Rated Value":"600 V","Ramp-Down Time Of Soft Starter":"0 ... 20 s","at 230 V at 40 °C rated value":"160 kW","at 400 V at 40 °C rated value":"315 kW","at 500 V at 40 °C rated value":"355 kW","Width Of Connection Bar Maximum":"35 mm; with connection cover 3RT1966-4EA1 maximum length 45 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"150 hp","at 220/230 V at 50 °C rated value":"200 hp","at 460/480 V at 50 °C rated value":"400 hp","at 575/600 V at 50 °C rated value":"500 hp","of circuit breaker usable at 400 V":"3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA","of circuit breaker usable at 500 V":"3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA","at the digital inputs at AC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","of line contactor usable up to 480 V":"3TF68","of line contactor usable up to 690 V":"3TF68","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","accuracy class according to IEC 61557-12":"5 %","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"124 ... 210 lbf·in","At Rotary Coding Switch On Switch Position 1":"240 A","At Rotary Coding Switch On Switch Position 2":"262 A","At Rotary Coding Switch On Switch Position 3":"284 A","At Rotary Coding Switch On Switch Position 4":"306 A","At Rotary Coding Switch On Switch Position 5":"328 A","At Rotary Coding Switch On Switch Position 6":"350 A","At Rotary Coding Switch On Switch Position 7":"372 A","At Rotary Coding Switch On Switch Position 8":"394 A","At Rotary Coding Switch On Switch Position 9":"416 A","at AWG cables for main current circuit solid":"2/0 ... 500 kcmil","for DIN cable lug for main contacts stranded":"50 ... 240 mm²","At Rotary Coding Switch On Switch Position 10":"438 A","At Rotary Coding Switch On Switch Position 11":"460 A","At Rotary Coding Switch On Switch Position 12":"482 A","At Rotary Coding Switch On Switch Position 13":"504 A","At Rotary Coding Switch On Switch Position 14":"526 A","At Rotary Coding Switch On Switch Position 15":"548 A","At Rotary Coding Switch On Switch Position 16":"570 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Holding Current In Bypass Operation Rated Value":"490 mA","utilization category according to IEC 60947-4-2":"AC-53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","for DIN cable lug for main contacts finely stranded":"70 ... 240 mm²","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; derating as of 1000 m, see Manual","Locked-Rotor Current At Close Of Bypass Contact Maximum":"7.6 A","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"min. 2x 70 mm², max. 2x 240 mm²","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"min. 2x 70 mm², max. 2x 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"120 ... 240 mm²","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3 340-8; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"95 ... 300 mm²","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"120 ... 240 mm²","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1 437-2; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"95 ... 300 mm²","at AWG cables for main contacts for box terminal using the back clamping point":"250 ... 500 kcmil","at AWG cables for main contacts for box terminal using the front clamping point":"3/0 ... 600 kcmil","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded Without Core End Processing":"min. 2x 50 mm², max. 2x 185 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"70 ... 240 mm²","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded Without Core End Processing":"120 ... 185 mm²","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded Without Core End Processing":"70 ... 240 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/64029329e8f0270ee32fb26ea7578369.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830815&mlfb=3RW5077-6AB05"},"ai":{"faq":[{"question":"What are the ATEX and IECEx ratings on the 3RW5077-6AB05?","answer":"Both ATEX and IECEx certification are listed on this soft starter variant. This qualifies the unit for installation in potentially explosive atmospheres (Zone 2 gas, Zone 22 dust), subject to the specific equipment group and temperature class marked on the nameplate."},{"question":"What fieldbus protocols does the 3RW5077-6AB05 support natively?","answer":"The base unit supports PROFIBUS, PROFINET (standard), Modbus RTU, Modbus TCP, and EtherNet/IP. No external gateway module is required for these protocols. PROFIenergy is available when used with the PROFINET communication module."},{"question":"What is the minimum motor current rating for the 3RW5077-6AB05?","answer":"The minimum settable operating current is 240 A. The minimum load is 15% relative to the smallest settable Ie, meaning the starter can handle motors with a full-load current as low as approximately 36 A (15% of 240 A)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5077-6AB05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5077-6AB05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}