{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5116-1XC14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5116-1XC14","canonicalUrl":"https://aoctrl.com/siemens/3RW5116-1XC14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5116-1XC14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5116-1XC14 soft starter, 200-480 V, trip class 10A, PROFIBUS and PROFINET, screw fixing.","salesMarkdown":"The 3RW5116-1XC14 is a SIRIUS soft starter sized for three-phase induction motors on 200-480 VAC lines. The trip class defaults to CLASS 10A per IEC 60947-4-2, meaning it clears a locked-rotor condition within 10 seconds at 7x FLA — standard for most pump, fan, and conveyor starts. You can parameterize it to 10E or 20E if the application needs a longer acceleration ramp (high-inertia loads like a centrifuge or a long belt). The minimum settable motor current is 14 A, so it covers the lower end of the medium-horsepower range without over-sizing the bypass. The control voltage accepts 110-250 V at both 50 and 60 Hz, which keeps the control transformer common across global panels. Communication comes with PROFIBUS and PROFINET onboard — no option card needed for either fieldbus. The analog output defaults to 4-20 mA but can be switched to 0-10 V through the HMI module, giving the DCS a motor-current or ramp-progress signal without a separate transducer. Mounts via screw fixing on a vertical surface; the enclosure allows +/-10° rotation and forward/backward tilt. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward — the back can sit flat against the panel backplate. That 100 mm upward gap is critical for heat plume rise; crowding it forces derating. The protection class is IP00 out of the box — IP20 is achievable with the optional terminal covers (3RW5980-0HS00) for vertical touch protection. In a pulp mill switchroom that hits 45 °C in summer, you need to either up-size the starter or add forced ventilation. Shock resistance is 15 g / 11 ms; vibration tolerance is 15 mm at 6 Hz and 2 g up to 500 Hz, which handles most motor-starter cubicle vibration without contact chatter.","metaTitle":"Siemens 3RW5116-1XC14 SIRIUS Soft Starter, 200-480 V","metaDescription":"Siemens 3RW5116-1XC14 SIRIUS soft starter, rated 200-480 V, trip class 10A (10E/20E selectable), PROFIBUS/PROFINET. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","title":"3RW5116-1XC14","Height":"321 mm","Minimum":"14 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","Auto-reset":"Yes","Modbus RTU":"No","Trip class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","At The Side":"5 mm","Rated Value":"200 ... 480 V","Soft Torque":"Yes","description":"SIRIUS soft starter 200-480 V 32 A, 110-250 V AC Screw terminals without bypass, Analog output","Remote Reset":"Yes; By turning off the control supply voltage","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes","Mounting type":"screw fixing","Service factor":"1","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Minimum load [%]":"15 %; Relative to smallest settable Ie","Shock resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting position":"+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface","PROFINET standard":"Yes","Product brand name":"SIRIUS","Degree of pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Protection class IP":"IP00; IP20 with additional terminal covers for vertical touching from the front","Inside-delta circuit":"Yes","Starting voltage [%]":"30 ... 100 %","Stopping voltage [%]":"50 ... 50 %","Vibration resistance":"15 mm to 6 Hz; 2g to 500 Hz","of HMI module usable":"3RW5980-0HS00","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"55.4 A","at 40 °C to power-up":"12 W","at 50 °C rated value":"49 A","at 50 °C to power-up":"12 W","at 60 °C rated value":"45 A","at 60 °C to power-up":"12 W","Communication Function":"Yes","Digital output version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","For Main Current Circuit":"box terminal","Number of analog outputs":"1","Number of digital inputs":"1","Weight without packaging":"5.2 kg","at 50 °C during startup":"323 W","at 60 °C during startup":"291 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes","Number of digital outputs":"3","Via Software Configurable":"No","is supported HMI-Standard":"Yes","Impulse voltage rated value":"6 kV","Intrinsic device protection":"Yes","Number of controlled phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable current limitation":"Yes","Electromagnetic compatibility":"acc. to IEC 60947-4-2","Stopping time of soft starter":"0 ... 20 s","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","at 230 V at 40 °C rated value":"7.5 kW","at 400 V at 40 °C rated value":"15 kW","At Inside-Delta Circuit Minimum":"24.2 A","Control supply voltage frequency":"50 ... 60 Hz","Operating measured value display":"Yes","during storage acc. to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","of HMI-Modul high-feature usable":"3RW5980-0HF00","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of the gG fuse usable up to 690 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V","Start-up ramp time of soft starter":"0 ... 20 s","during operation acc. to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport acc. to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of circuit breaker usable at 400 V":"3RV2032-4VA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4VA10; Type of coordination 1, Iq = 10 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","at the digital inputs at AC maximum":"100 m","Design of the overvoltage protection":"Varistor","Surge voltage resistance rated value":"6 kV","Usage category acc. to IEC 60947-4-2":"AC-53b","Current limiting value [%] adjustable":"130 ... 700 %","Reference code acc. to DIN EN 81346-2":"Q","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","of communication module PROFIBUS usable":"3RW5980-0CP00","Blocking voltage of the thyristor maximum":"1 400 V","of communication module Modbus RTU usable":"3RW5980-0CR00","Type of voltage of the control supply voltage":"AC","At Rotary Encoding Switch On Switch Position 1":"24.2 A","At Rotary Encoding Switch On Switch Position 2":"26.3 A","At Rotary Encoding Switch On Switch Position 3":"28.4 A","At Rotary Encoding Switch On Switch Position 4":"30.5 A","At Rotary Encoding Switch On Switch Position 5":"32.6 A","At Rotary Encoding Switch On Switch Position 6":"34.6 A","At Rotary Encoding Switch On Switch Position 7":"36.7 A","At Rotary Encoding Switch On Switch Position 8":"38.8 A","At Rotary Encoding Switch On Switch Position 9":"40.9 A","At Rotary Encoding Switch On Switch Position 10":"43 A","At Rotary Encoding Switch On Switch Position 11":"45 A","At Rotary Encoding Switch On Switch Position 12":"47.1 A","At Rotary Encoding Switch On Switch Position 13":"49.2 A","At Rotary Encoding Switch On Switch Position 14":"51.3 A","At Rotary Encoding Switch On Switch Position 15":"53.3 A","At Rotary Encoding Switch On Switch Position 16":"55.4 A","Product feature integrated bypass contact system":"No","of communication module PROFINET standard usable":"3RW5980-0CS00","Control supply current in standby mode rated value":"30 mA","Relative negative tolerance of the operating voltage":"-15 %","Relative positive tolerance of the operating voltage":"10 %","Design of short-circuit protection for control circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative negative tolerance of the operating frequency":"-10 %","Relative positive tolerance of the operating frequency":"10 %","Installation altitude at height above sea level maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4JA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4JA10; Type of coordination 1, Iq = 10 kA, CLASS 10","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Inrush current peak at connect of control supply voltage maximum":"12.2 A","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative negative tolerance of the control supply voltage frequency":"-10 %","Relative positive tolerance of the control supply voltage frequency":"10 %","Duration of inrush current peak at connect of control supply voltage":"2.2 ms","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8022-1; Type of coordination 2, (soft starter in conjunction with the associated protective device circuit breaker/fuse), Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","Relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","Relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","Relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1818-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","Relative negative tolerance of the operating voltage at inside-delta circuit":"-15 %","Relative positive tolerance of the operating voltage at inside-delta circuit":"10 %","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/90715aa62065cc4a5752cba9ff084908.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830825&mlfb=3RW5116-1XC14"},"ai":{"faq":[{"question":"Where can I buy a Siemens 3RW5116-1XC14 soft starter?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability — lead time and stock are confirmed at quote time."},{"question":"Does the 3RW5116-1XC14 require an external bypass contactor?","answer":"The soft starter supports an inside-delta circuit configuration, which reduces line current during bypass. An external bypass contactor is not mandatory — the unit can run in continuous-duty mode — but adding one extends starter life by taking the thyristors out of the circuit after the motor reaches full speed."},{"question":"What is 3RW5116-1XC14's listed depth?","answer":"The depth is 203 mm, with a width of 185 mm and a height of 321 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5116-1XC14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5116-1XC14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}