{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5134-1XC14-0S","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5134-1XC14-0S","canonicalUrl":"https://aoctrl.com/siemens/3RW5134-1XC14-0S","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5134-1XC14-0S","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5134-1XC14-0S soft starter, 53 A minimum, 200-480 V, Trip Class 10A, PROFIBUS/Modbus RTU/PROFINET, screw fixing, 324x185x203 mm.","salesMarkdown":"## Trip class and overload protection — what it means for motor starting The 3RW5134-1XC14-0S is configured with Trip Class 10A as default, with selectable 10E and 20E classes per IEC 60947-4-2. Rated minimum current is 53 A, so this unit is sized for motor loads drawing at least that at full load. The voltage range covers 200 to 480 V, covering common low-voltage industrial supplies across 50/60 Hz systems. ## Fieldbus and control — PROFIBUS, Modbus RTU, PROFINET onboard This soft starter ships with PROFIBUS, Modbus RTU, and PROFINET standard interfaces — no separate communication module needed. That means it drops into a Siemens S7 environment or any Modbus TCP/PROFINET controller without a gateway. The control circuit uses screw-type terminals, and the unit supports voltage ramp start, soft torque, and ramp-down soft stop — giving you adjustable acceleration and deceleration profiles for pumps, conveyors, and fans where mechanical shock matters. ## Mounting and clearances — panel fit checklist Dimensions are 324 mm high, 185 mm wide, 203 mm deep. Mounting is by screw fixing, with the unit positionable on a vertical surface with ±90° rotation and ±22.5° tilt front/back. Required clearances: 100 mm upwards, 10 mm forwards, 75 mm downwards, 5 mm at the sides, and 0 mm backwards — so plan for airflow above and below. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments with conductive dust or occasional condensation.","metaTitle":"Siemens 3RW5134-1XC14-0S Soft Starter, 53 A, 200-480 V","metaDescription":"Siemens 3RW5134-1XC14-0S soft starter, rated 53 A minimum, 200-480 V, Trip Class 10A per IEC 60947-4-2. Active production. Quoted to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","title":"3RW5134-1XC14-0S","Height":"324 mm","Minimum":"53 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","Modbus RTU":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","Rated Value":"200 ... 480 V","Soft Torque":"Yes","description":"SIRIUS soft starter 200-480 V 113 A, 110-250 V AC screw terminals without bypass, analog output with HMI standard","HMI-Standard":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes","Service Factor":"1","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"196 A","at 50 °C rated value":"175 A","at 60 °C rated value":"154 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"12 W","at 50 °C after startup":"12 W","at 60 °C after startup":"12 W","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"6.45 kg","at 40 °C during startup":"1 512 W","at 50 °C during startup":"1 291 W","at 60 °C during startup":"1 086 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes","Number Of Digital Outputs":"3","Via Software Configurable":"No","Impulse Voltage Rated Value":"6 V","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","at AC-15 at 250 V rated value":"3 A","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"480 V","Ramp-Down Time Of Soft Starter":"0 ... 20 s","at 230 V at 40 °C rated value":"30 W","at 400 V at 40 °C rated value":"55 W","At Inside-Delta Circuit Minimum":"91.8 A","Width Of Connection Bar Maximum":"25 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; with optional HMI","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3244-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","of circuit breaker usable at 400 V":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","at the digital inputs at AC maximum":"100 m","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 400 V","of communication module Modbus RTU usable":"3RW5980-0CR00","For Main Contacts With Screw-Type Terminals":"89 ... 124 lbf·in","At Rotary Coding Switch On Switch Position 1":"53 A","At Rotary Coding Switch On Switch Position 2":"57 A","At Rotary Coding Switch On Switch Position 3":"61 A","At Rotary Coding Switch On Switch Position 4":"65 A","At Rotary Coding Switch On Switch Position 5":"69 A","At Rotary Coding Switch On Switch Position 6":"73 A","At Rotary Coding Switch On Switch Position 7":"77 A","At Rotary Coding Switch On Switch Position 8":"81 A","At Rotary Coding Switch On Switch Position 9":"85 A","for DIN cable lug for main contacts stranded":"2x (16 ... 95 mm²)","At Rotary Coding Switch On Switch Position 10":"89 A","At Rotary Coding Switch On Switch Position 11":"93 A","At Rotary Coding Switch On Switch Position 12":"97 A","At Rotary Coding Switch On Switch Position 13":"101 A","At Rotary Coding Switch On Switch Position 14":"105 A","At Rotary Coding Switch On Switch Position 15":"109 A","At Rotary Coding Switch On Switch Position 16":"113 A","Type Of Voltage Of The Control Supply Voltage":"AC","utilization category according to IEC 60947-4-2":"AC-53b","Product Feature Integrated Bypass Contact System":"No","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","for DIN cable lug for main contacts finely stranded":"2x (25 ... 120 mm²)","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 mm; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3244-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2220-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"91.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"98.7 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"106 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"113 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"120 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"126 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"133 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"140 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"147 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"154 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"161 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"168 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"175 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"182 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"189 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"196 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3332-0B; Type of coordination 2, (soft starter in conjunction with the associated protective device circuit breaker/fuse), Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1225-0; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1249f7cbcf1a62bfcb7864daff53eaf9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1496066&mlfb=3RW5134-1XC14-0S"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3RW5134-1XC14-0S?","answer":"Submit an RFQ through this listing."},{"question":"What communication protocols does the 3RW5134-1XC14-0S support?","answer":"It supports PROFIBUS, Modbus RTU, and PROFINET standard interfaces onboard, plus an analog output configurable for 4-20 mA or 0-10 V feedback."},{"question":"What are the mounting clearances required for this soft starter?","answer":"Minimum clearances: 100 mm above, 10 mm in front, 75 mm below, 5 mm at the sides, and 0 mm behind."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5134-1XC14-0S","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5134-1XC14-0S when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}