{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5214-1AC05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5214-1AC05","canonicalUrl":"https://aoctrl.com/siemens/3RW5214-1AC05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5214-1AC05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5214-1AC05 soft starter, 200-600 V, Class 10A/10E/20E, with PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, and analog output.","salesMarkdown":"## SIRIUS 3RW5214-1AC05 Soft Starter — Field Note The Siemens 3RW5214-1AC05 is a SIRIUS hybrid soft starter rated for 200-600 V supply, with a minimum settable current of 7.5 A. It's built for three-phase induction motor starting, with the trip class configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. That means it protects the motor during start-up by limiting inrush, and the trip class tells you how long it can hold the current before thermal overload — 10A is the standard for normal starts, 10E for extended ramp, 20E for heavy inertia loads. On the communications side, this unit ships with PROFIBUS onboard, plus Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard. That's a full fieldbus slice for most PLC ecosystems — Siemens, Rockwell, Schneider — without extra option cards. The analog output is 4-20 mA (default) or 0-10 V, parameterizable with a High Feature HMI. It also includes soft torque and pump ramp down features, which reduce mechanical stress on the load and prevent water hammer in pump applications. Remote reset is handled by cycling the 24 V control supply. Mounting is screw-fix to a vertical surface, with +/-10° rotation allowance. Dimensions are 275 mm height, 170 mm width, 152 mm depth — fits a standard enclosure depth. Mounting is screw-fix to a vertical surface; the unit can be tilted +/-10° forward or backward. Clearance requirements: 100 mm upward, 10 mm forward, 75 mm downward, 5 mm at the side, 0 mm backward. That's tight side clearance but generous top and bottom for cable entry and airflow. The power terminals accept 2x (1.0-2.5 mm²) and 2x (2.5-10 mm²) solid/stranded — no special lug tooling needed. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms with potential contact lifting — fine for most industrial panels, but check if your application sees repetitive shock near that limit.","metaTitle":"Siemens 3RW5214-1AC05 SIRIUS Soft Starter, 200-600 V","metaDescription":"Siemens 3RW5214-1AC05 SIRIUS soft starter. Rated 200-600 V, Class 10A/10E/20E trip class. Supports PROFIBUS, Modbus TCP, EtherNet/IP. Currently active.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"152 mm","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5214-1AC05","Height":"275 mm","Minimum":"7.5 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 18 A, 24 V AC/DC Screw terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"31.5 A","at 50 °C rated value":"28 A","at 60 °C rated value":"23.9 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"17 W","at 50 °C after startup":"17 W","at 60 °C after startup":"16 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"2.1 kg","at 40 °C during startup":"276 W","at 50 °C during startup":"241 W","at 60 °C during startup":"200 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"4 kW","at 400 V at 40 °C rated value":"7.5 kW","at 500 V at 40 °C rated value":"11 kW","At Inside-Delta Circuit Minimum":"13 A","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"3 hp","at 220/230 V at 50 °C rated value":"5 hp","at 460/480 V at 50 °C rated value":"10 hp","at 575/600 V at 50 °C rated value":"10 hp","of circuit breaker usable at 400 V":"3RV2032-4DA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4DA10; Type of coordination 1, Iq = 15 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","at the digital inputs at AC maximum":"100 m","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"18 ... 22 lbf·in","At Rotary Coding Switch On Switch Position 1":"7.5 A","At Rotary Coding Switch On Switch Position 2":"8.2 A","At Rotary Coding Switch On Switch Position 3":"8.9 A","At Rotary Coding Switch On Switch Position 4":"9.6 A","At Rotary Coding Switch On Switch Position 5":"10.3 A","At Rotary Coding Switch On Switch Position 6":"11 A","At Rotary Coding Switch On Switch Position 7":"11.7 A","At Rotary Coding Switch On Switch Position 8":"12.4 A","At Rotary Coding Switch On Switch Position 9":"13.1 A","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","At Rotary Coding Switch On Switch Position 10":"13.8 A","At Rotary Coding Switch On Switch Position 11":"14.5 A","At Rotary Coding Switch On Switch Position 12":"15.2 A","At Rotary Coding Switch On Switch Position 13":"15.9 A","At Rotary Coding Switch On Switch Position 14":"16.6 A","At Rotary Coding Switch On Switch Position 15":"17.3 A","At Rotary Coding Switch On Switch Position 16":"18 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Holding Current In Bypass Operation Rated Value":"360 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Inrush Current By Closing The Bypass Contacts Maximum":"0.75 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4EA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4EA10; Type of coordination 1, Iq = 15 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"13 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"14.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"15.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"16.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"17.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"19.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"20.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"21.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"22.7 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"23.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"25.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"26.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"27.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"28.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"30 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"31.2 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8020-1; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1802-0; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/eb03e8b5fc3b22aaf260e4ee4de6cc2a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830857&mlfb=3RW5214-1AC05"},"ai":{"faq":[{"question":"What is the rated current and voltage for Siemens 3RW5214-1AC05?","answer":"The rated supply voltage is 200-600 V. The minimum settable current is 7.5 A. The trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2."},{"question":"What communication protocols does 3RW5214-1AC05 support?","answer":"It supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard. PROFIenergy is available in connection with the PROFINET Standard communication module."},{"question":"Does 3RW5214-1AC05 require an external overload relay?","answer":"No — this is a hybrid switching device with integrated overload protection. The trip class (CLASS 10A/10E/20E) is built in per IEC 60947-4-2, so no separate overload relay is needed for motor protection."},{"question":"What is the closest functional second-source for 3RW5214-1AC05?","answer":"The 3RT5036-1AB00 is a contactor, not a soft starter — it lacks the soft-start ramp, trip class, and integrated overload protection of the 3RW5214-1AC05. No direct second-source exists for this SIRIUS soft starter; the 3RW5214-1AC05 is the current active model in its class."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5214-1AC05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5214-1AC05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}