{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5215-1AC05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5215-1AC05","canonicalUrl":"https://aoctrl.com/siemens/3RW5215-1AC05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5215-1AC05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5215-1AC05 soft starter, 11.5 A minimum, 200-600 V, Class 10A/10E/20E, screw fixing, 275 x 170 x 152 mm.","salesMarkdown":"## What the trip class means for your motor start The 3RW5215-1AC05: That's the right call for standard induction motors driving pumps, fans, and compressors — anything that isn't a high-inertia load. If you're starting a centrifuge or a loaded conveyor, you can switch it to CLASS 10E or CLASS 20E to give the motor more time to accelerate. That's a parameter change, not a hardware swap. ## Fieldbus options — pick your network This soft starter supports PROFIBUS, PROFINET standard, Modbus RTU, Modbus TCP, and EtherNet/IP out of the box. That covers the vast majority of plant-floor networks — no separate gateway needed unless you're on DeviceNet or CANopen. PROFIenergy is available when paired with the PROFINET Standard communication module, letting you coordinate energy-saving pauses across a production line during idle periods. ## Mounting and clearances for the panel It mounts with screw fixing, not DIN rail — so budget for four holes in the backplate. The body is 275 mm tall, 170 mm wide, and 152 mm deep, which is a standard footprint for this SIRIUS frame size. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and zero behind. That's tight side-to-side but generous top-to-bottom for cable entry and airflow. The power terminals accept 1.0 to 2.5 mm² on the smaller set and 2.5 to 10 mm² on the larger — fine for the 11.5 A minimum rating. Control wiring is 24 V DC. ## Environmental limits and derating Ambient operating temperature is -25 to +60 °C, but Siemens flags derating above 40 °C. If your panel hits 50 °C, you'll need to reduce the continuous current or add forced ventilation — the spec says 'please observe derating' without giving the curve, so check the manual for the exact factor. Shock resistance is 15 g for 11 ms, dropping to 12 g if you risk contact lifting. That's fine for most industrial floors but marginal near a stamping press or drop forge — mount on vibration isolators if that's your environment. ## Lifecycle and sourcing We source this against your BOM quantity and confirm current pricing and lead time at quote. No stock-holding claim here — it's quoted to order from authorized Siemens distribution.","metaTitle":"Siemens 3RW5215-1AC05 SIRIUS Soft Starter, 11.5 A, 200-600 V","metaDescription":"Siemens 3RW5215-1AC05 SIRIUS soft starter, rated 11.5 A minimum at 200-600 V. Active production, sourced to order. UL, CSA, CE approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"152 mm","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5215-1AC05","Height":"275 mm","Minimum":"11.5 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 25 A, 24 V AC/DC Screw terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"43.3 A","at 50 °C rated value":"39 A","at 60 °C rated value":"33.9 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"20 W","at 50 °C after startup":"19 W","at 60 °C after startup":"18 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"2.1 kg","at 40 °C during startup":"376 W","at 50 °C during startup":"318 W","at 60 °C during startup":"278 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"5.5 kW","at 400 V at 40 °C rated value":"11 kW","at 500 V at 40 °C rated value":"15 kW","At Inside-Delta Circuit Minimum":"19.9 A","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3822-6 ; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"5 hp","at 220/230 V at 50 °C rated value":"7.5 hp","at 460/480 V at 50 °C rated value":"15 hp","at 575/600 V at 50 °C rated value":"20 hp","of circuit breaker usable at 400 V":"3RV2032-4EA10 ; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4EA10 ; Type of coordination 1, Iq = 15 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","at the digital inputs at AC maximum":"100 m","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"18 ... 22 lbf·in","At Rotary Coding Switch On Switch Position 1":"11.5 A","At Rotary Coding Switch On Switch Position 2":"12.4 A","At Rotary Coding Switch On Switch Position 3":"13.3 A","At Rotary Coding Switch On Switch Position 4":"14.2 A","At Rotary Coding Switch On Switch Position 5":"15.1 A","At Rotary Coding Switch On Switch Position 6":"16 A","At Rotary Coding Switch On Switch Position 7":"16.9 A","At Rotary Coding Switch On Switch Position 8":"17.8 A","At Rotary Coding Switch On Switch Position 9":"18.7 A","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","At Rotary Coding Switch On Switch Position 10":"19.6 A","At Rotary Coding Switch On Switch Position 11":"20.5 A","At Rotary Coding Switch On Switch Position 12":"21.4 A","At Rotary Coding Switch On Switch Position 13":"22.3 A","At Rotary Coding Switch On Switch Position 14":"23.2 A","At Rotary Coding Switch On Switch Position 15":"24.1 A","At Rotary Coding Switch On Switch Position 16":"25 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Holding Current In Bypass Operation Rated Value":"360 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Inrush Current By Closing The Bypass Contacts Maximum":"0.75 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3822-6 ; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4VA10 ; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4VA10 ; Type of coordination 1, Iq = 15 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"19.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"21.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"23 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"24.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"26.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"27.7 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"29.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"30.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"32.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"33.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"35.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"37.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"38.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"40.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"41.7 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"43.3 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8021-1 ; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1817-0 ; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$617.22","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8152e68fc2cda1f19c926b84d0eb880.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830873&mlfb=3RW5215-1AC05"},"ai":{"faq":[{"question":"What compliance documentation does the 3RW5215-1AC05 carry?","answer":"It holds UL approval, CSA approval, and CE marking. That covers US, Canadian, and European regulatory acceptance for industrial control equipment."},{"question":"What voltage range does the 3RW5215-1AC05 work with?","answer":"The rated voltage range is 200 to 600 V AC, which covers common global motor voltages from 208 V to 480 V and 600 V Canadian systems."},{"question":"Can this soft starter handle pump applications with soft stop?","answer":"Yes, it includes a pump ramp down function that gradually reduces voltage during stopping, minimizing water hammer in pumping systems."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5215-1AC05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5215-1AC05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}