{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5215-1AC14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5215-1AC14","canonicalUrl":"https://aoctrl.com/siemens/3RW5215-1AC14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5215-1AC14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5215-1AC14 soft starter, hybrid switching device, 200-480 VAC, 11.5 A minimum, Trip Class 10A/10E/20E, screw fixing, 275x170x152 mm, active production.","salesMarkdown":"## Panel fit and mounting — 275 x 170 x 152 mm, screw-fixed The 3RW5215-1AC14 measures 275 mm high, 170 mm wide, and 152 mm deep, with screw fixing to the back panel. It allows ±10° rotation and can tilt forward or backward on a vertical surface, so you can nudge it into an existing enclosure without redrilling the whole backplate. Clearance requirements are specific: 100 mm above, 75 mm below, 10 mm forward, 0 mm backward, and 5 mm at the sides. The zero backward clearance means it can sit flush against a rear panel wall, which helps when the enclosure depth is tight. ## Motor starting profile — Trip Class 10A, minimum 11.5 A Rated for a minimum setting of 11.5 A, this soft starter is sized for smaller motor loads. The Trip Class is selectable: default CLASS 10A, with options for 10E or 20E per IEC 60947-4-2. The minimum load threshold is 15% of the smallest settable Ie, so it handles light-load starts without nuisance tripping. Service factor is 1 — no built-in overload margin beyond the nameplate rating, so set the motor FLA accurately in the parameters. ## Network integration — PROFIBUS, Modbus, EtherNet/IP, PROFINET This unit ships with onboard PROFIBUS and Modbus RTU, plus Modbus TCP and EtherNet/IP support. PROFINET standard is also available, and with the PROFINET communication module you get PROFIenergy for coordinated energy management in automated lines. The analog output is configurable as 4-20 mA (default) or 0-10 V, parameterizable through the High Feature HMI. This gives the PLC real-time current feedback for load monitoring or predictive maintenance triggers. ## Operating conditions and approvals Shock resistance is 15 g / 11 ms, with potential contact lifting at 12 g / 11 ms, so it holds up in industrial environments with vibration from nearby contactors or drives. Carries CE, UL, and CSA approvals, covering North American and European regulatory requirements. The product category is hybrid switching devices, meaning it uses a semiconductor for soft starting and an electromechanical bypass for steady-state running — lower heat dissipation in the panel than a pure solid-state starter.","metaTitle":"Siemens 3RW5215-1AC14 Soft Starter, 200-480 V, 11.5 A","metaDescription":"Siemens 3RW5215-1AC14 soft starter, 200-480 VAC, 11.5 A min, Trip Class 10A/10E/20E. Active production. UL/CSA/CE.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"152 mm","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5215-1AC14","Height":"275 mm","Minimum":"11.5 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 480 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 25 A, 110-250 V AC Screw terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"43.3 A","at 50 °C rated value":"39 A","at 60 °C rated value":"33.9 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"20 W","at 50 °C after startup":"19 W","at 60 °C after startup":"18 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"2.1 kg","at 40 °C during startup":"376 W","at 50 °C during startup":"318 W","at 60 °C during startup":"278 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"5.5 kW","at 400 V at 40 °C rated value":"11 kW","At Inside-Delta Circuit Minimum":"19.9 A","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3822-6 ; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"5 hp","at 220/230 V at 50 °C rated value":"7.5 hp","at 460/480 V at 50 °C rated value":"15 hp","of circuit breaker usable at 400 V":"3RV2032-4EA10 ; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4EA10 ; Type of coordination 1, Iq = 15 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","at the digital inputs at AC maximum":"100 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"18 ... 22 lbf·in","At Rotary Coding Switch On Switch Position 1":"11.5 A","At Rotary Coding Switch On Switch Position 2":"12.4 A","At Rotary Coding Switch On Switch Position 3":"13.3 A","At Rotary Coding Switch On Switch Position 4":"14.2 A","At Rotary Coding Switch On Switch Position 5":"15.1 A","At Rotary Coding Switch On Switch Position 6":"16 A","At Rotary Coding Switch On Switch Position 7":"16.9 A","At Rotary Coding Switch On Switch Position 8":"17.8 A","At Rotary Coding Switch On Switch Position 9":"18.7 A","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","At Rotary Coding Switch On Switch Position 10":"19.6 A","At Rotary Coding Switch On Switch Position 11":"20.5 A","At Rotary Coding Switch On Switch Position 12":"21.4 A","At Rotary Coding Switch On Switch Position 13":"22.3 A","At Rotary Coding Switch On Switch Position 14":"23.2 A","At Rotary Coding Switch On Switch Position 15":"24.1 A","At Rotary Coding Switch On Switch Position 16":"25 A","Type Of Voltage Of The Control Supply Voltage":"AC","Holding Current In Bypass Operation Rated Value":"75 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Inrush Current By Closing The Bypass Contacts Maximum":"0.17 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3822-6 ; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4VA10 ; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4VA10 ; Type of coordination 1, Iq = 15 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"19.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"21.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"23 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"24.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"26.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"27.7 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"29.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"30.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"32.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"33.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"35.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"37.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"38.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"40.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"41.7 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"43.3 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8021-1 ; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1817-0 ; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/439fc39600e62a9673316f11979affe6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830874&mlfb=3RW5215-1AC14"},"ai":{"faq":[{"question":"What is the 3RW5215-1AC14's depth?","answer":"The depth is 152 mm, with a width of 170 mm and height of 275 mm. It mounts via screw fixing and requires 100 mm clearance above, 75 mm below, 10 mm forward, 0 mm backward, and 5 mm at the sides."},{"question":"What compliance documentation does Siemens provide for the 3RW5215-1AC14?","answer":"The unit carries CE marking for European markets, plus UL and CSA approvals for North America. It is classified as a hybrid switching device under IEC 60947-4-2 for soft starters."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5215-1AC14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5215-1AC14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}