{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5217-1TC04","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5217-1TC04","canonicalUrl":"https://aoctrl.com/siemens/3RW5217-1TC04","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5217-1TC04","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5217-1TC04 hybrid soft starter, 200-480 VAC, 15.5 A minimum load, CLASS 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP/PROFINET, screw fixing, 170x275x152 mm.","salesMarkdown":"## Motor starting envelope — voltage, current, trip class The 3RW5217-1TC04: Rated supply voltage 200–480 VAC covers the common low-voltage motor bus in North America and Europe without a transformer tap. Also selectable CLASS 10E and 20E for higher-inertia loads like centrifuges or crushers where the start profile needs more time before the overload trip engages. ## Fieldbus and control integration — five protocols on one unit Native support for PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard means this single order code fits into any major control architecture without a separate gateway module. PROFINET variant also carries PROFIenergy for coordinated load shedding during production pauses. Remote reset cycles the control supply voltage (24 VDC) — no separate reset signal wire needed. Auto-reset is also configurable for unattended restart after a cleared fault, typical in pump or conveyor stations. ## Panel fit — dimensions, clearance, mounting orientation 170 mm wide, 275 mm high, 152 mm deep — mounts via screw fixing to a vertical surface. Clearance requirements: 100 mm above, 75 mm below, 10 mm front, 5 mm sides, 0 mm rear. The zero rear clearance means the unit can sit flush against a back panel or enclosure wall without an air gap. Mounting position allows ±90° rotation and ±22.5° tilt forward/back from vertical — useful when the enclosure layout forces an angled or horizontal orientation. Shock rated 15 g / 11 ms, derated to 12 g if contact lifting is a concern. ## Environmental and wiring limits Operating ambient -25 to +60 °C with derating required above 40 °C — the heatsink sizing assumes free air convection; stacking or enclosed mounting above 40 °C needs the derating curve applied. Power terminals accept solid wire 2x (1.0–2.5 mm²) and 2x (2.5–10 mm²) — the larger cross-section handles the main motor feed, the smaller for control loop wiring. ## Lifecycle and compliance — active production, global approvals Listed as current production — no end-of-life notice or last-time-buy trigger. UL and CSA approvals cover North American panel builds; CE marking covers European machinery directive compliance.","metaTitle":"Siemens 3RW5217-1TC04 SIRIUS Soft Starter, 200-480 V","metaDescription":"Siemens 3RW5217-1TC04 SIRIUS hybrid soft starter, 200-480 VAC, 15.5 A minimum, CLASS 10A/10E/20E trip. UL/CSA/CE. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"152 mm","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5217-1TC04","Height":"275 mm","Minimum":"15.5 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 480 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 38 A, 24 V AC/DC Screw terminals Thermistor input","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"No","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"65.8 A","at 50 °C rated value":"58 A","at 60 °C rated value":"52.8 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"23 W","at 50 °C after startup":"22 W","at 60 °C after startup":"21 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"0","Number Of Digital Inputs":"1","Weight Without Packaging":"2.3 kg","at 40 °C during startup":"628 W","at 50 °C during startup":"526 W","at 60 °C during startup":"464 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"11 kW","at 400 V at 40 °C rated value":"18.5 kW","At Inside-Delta Circuit Minimum":"26.8 A","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA ; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"10 hp","at 220/230 V at 50 °C rated value":"10 hp","at 460/480 V at 50 °C rated value":"20 hp","of circuit breaker usable at 400 V":"3RV2032-4WA10; Type of coordination 1, Iq = 65 kA, CLASS 10 ; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4WA10; Type of coordination 1, Iq = 10 kA, CLASS 10 ; Type of coordination 1, Iq = 10 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","at the digital inputs at AC maximum":"100 m","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"18 ... 22 lbf·in","At Rotary Coding Switch On Switch Position 1":"15.5 A","At Rotary Coding Switch On Switch Position 2":"17 A","At Rotary Coding Switch On Switch Position 3":"18.5 A","At Rotary Coding Switch On Switch Position 4":"20 A","At Rotary Coding Switch On Switch Position 5":"21.5 A","At Rotary Coding Switch On Switch Position 6":"23 A","At Rotary Coding Switch On Switch Position 7":"24.5 A","At Rotary Coding Switch On Switch Position 8":"26 A","At Rotary Coding Switch On Switch Position 9":"27.5 A","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","At Rotary Coding Switch On Switch Position 10":"29 A","At Rotary Coding Switch On Switch Position 11":"30.5 A","At Rotary Coding Switch On Switch Position 12":"32 A","At Rotary Coding Switch On Switch Position 13":"33.5 A","At Rotary Coding Switch On Switch Position 14":"35 A","At Rotary Coding Switch On Switch Position 15":"36.5 A","At Rotary Coding Switch On Switch Position 16":"38 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"360 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Inrush Current By Closing The Bypass Contacts Maximum":"0.75 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply; Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA ; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4RA10; Type of coordination 1, Iq = 65 kA, CLASS 10 ; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4RA10; Type of coordination 1, Iq = 10 kA, CLASS 10 ; Type of coordination 1, Iq = 10 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"26.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"29.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"32 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"34.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"37.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"39.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"42.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"45 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"47.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"50.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"52.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"55.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"58 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"60.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"63.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"65.8 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8024-1; Type of coordination 2, Iq = 65 kA ; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1820-0; Type of coordination 2, Iq = 65 kA ; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/24d3afca8b9c1a74f120c459468fe106.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830908&mlfb=3RW5217-1TC04"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 3RW5217-1TC04?","answer":"The unit carries CE marking for the European market, UL approval for North America, and CSA approval for Canada. RoHS and REACH declarations are standard with the SIRIUS series; the specific declarations are included with the shipment documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5217-1TC04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5217-1TC04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}