{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5224-3AC05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5224-3AC05","canonicalUrl":"https://aoctrl.com/siemens/3RW5224-3AC05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5224-3AC05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5224-3AC05 hybrid switching device, soft starter, 200-600 V, trip class 10A/10E/20E, screw fixing, 203 x 185 x 306 mm.","salesMarkdown":"## Soft starter for motor control — what the ratings mean The 3RW5224-3AC05 is a SIRIUS-brand hybrid switching device — a soft starter, not a VFD — designed to ramp motors up and down, limiting inrush current and mechanical shock on conveyors, pumps, and fans. Rated voltage range is 200 to 600 V, covering common global line voltages from 208 V to 600 V without needing a separate transformer tap. Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2 — this sets the maximum allowable overload time before the starter trips, so matching the motor's thermal withstand curve is straightforward. Minimum load is 15 % relative to the smallest settable Ie — if the motor is significantly oversized for the driven load, the starter may not detect a true overload condition. ## Fieldbus and control connectivity — what's on board Onboard fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard — the starter integrates into most common industrial networks without an external gateway. PROFIenergy is supported in conjunction with the PROFINET standard communication module — this allows the drive to be put into an energy-saving state during production pauses. Analog output is configurable as 4-20 mA (default) or 0-10 V (parameterizable with High Feature HMI) — useful for feeding a current signal to a PLC or panel meter. Remote reset is achieved by cycling the control supply voltage (24 V DC) — no separate reset button needed in the panel. ## Mounting, cooling, and panel fit Fastening method is screw fixing — not DIN-rail snap-on — so the panel must have a mounting plate or threaded inserts at the correct hole pattern. Mounting position allows +/- 10° rotation and can be tilted forward or backward on a vertical mounting surface — useful when the enclosure layout is tight. Required clearances: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, 5 mm at the side — these are the minimum air gaps for heat dissipation and arc flash protection. ## Compliance and approvals — UL, CSA, CE, pollution degree 3 UL, CSA, and CE marking are all confirmed — the starter is accepted in North American and European installations without additional agency review. Pollution degree 3 per IEC 60947-4-2 — suitable for industrial environments with conductive pollution (dust, moisture, chemical fumes) typical of factory floors. Shock resistance is 15 g / 11 ms, with potential contact lifting from 12 g / 11 ms — adequate for most rotating equipment but not extreme vibration environments.","metaTitle":"Siemens 3RW5224-3AC05 SIRIUS Soft Starter, 200-600 V","metaDescription":"Siemens SIRIUS 3RW5224-3AC05 soft starter, rated 200-600 V, trip class 10A/10E/20E per IEC 60947-4-2. UL/CSA/CE approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","title":"3RW5224-3AC05","Height":"306 mm","Minimum":"20 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 47 A, 24 V AC/DC spring-type terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"81.4 A","at 50 °C rated value":"72 A","at 60 °C rated value":"62.7 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"26 W","at 50 °C after startup":"24 W","at 60 °C after startup":"23 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"5.2 kg","at 40 °C during startup":"606 W","at 50 °C during startup":"522 W","at 60 °C during startup":"438 W","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"11 kW","at 400 V at 40 °C rated value":"22 kW","at 500 V at 40 °C rated value":"30 kW","At Inside-Delta Circuit Minimum":"34.6 A","Width Of Connection Bar Maximum":"25 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"10 hp","at 220/230 V at 50 °C rated value":"10 hp","at 460/480 V at 50 °C rated value":"30 hp","at 575/600 V at 50 °C rated value":"40 hp","of circuit breaker usable at 400 V":"3RV2032-4JA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4JA10; Type of coordination 1, Iq = 10 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","at the digital inputs at AC maximum":"100 m","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 800 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","At Rotary Coding Switch On Switch Position 1":"20 A","At Rotary Coding Switch On Switch Position 2":"21.8 A","At Rotary Coding Switch On Switch Position 3":"23.6 A","At Rotary Coding Switch On Switch Position 4":"25.4 A","At Rotary Coding Switch On Switch Position 5":"27.2 A","At Rotary Coding Switch On Switch Position 6":"29 A","At Rotary Coding Switch On Switch Position 7":"30.8 A","At Rotary Coding Switch On Switch Position 8":"32.6 A","At Rotary Coding Switch On Switch Position 9":"34.4 A","At Rotary Coding Switch On Switch Position 10":"36.2 A","At Rotary Coding Switch On Switch Position 11":"38 A","At Rotary Coding Switch On Switch Position 12":"39.8 A","At Rotary Coding Switch On Switch Position 13":"41.6 A","At Rotary Coding Switch On Switch Position 14":"43.4 A","At Rotary Coding Switch On Switch Position 15":"45.2 A","At Rotary Coding Switch On Switch Position 16":"47 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Holding Current In Bypass Operation Rated Value":"380 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","Locked-Rotor Current At Close Of Bypass Contact Maximum":"7.6 A","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4RA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4RA10; Type of coordination 1, Iq = 10 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"34.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"37.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"40.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"44 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"47.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"50.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"53.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"56.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"59.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"62.7 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"65.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"68.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"72.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"75.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"78.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"81.4 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8024-1; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1021-2; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","at AWG cables for main contacts for box terminal using the front clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0aff94a3bd4e691a4b3d0500be001b50.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830529&mlfb=3RW5224-3AC05"},"ai":{"faq":[{"question":"What trip classes are available on 3RW5224-3AC05?","answer":"Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2."},{"question":"What approvals does 3RW5224-3AC05 carry?","answer":"UL, CSA, and CE marking are all confirmed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5224-3AC05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5224-3AC05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}