{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5224-3TC14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5224-3TC14","canonicalUrl":"https://aoctrl.com/siemens/3RW5224-3TC14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5224-3TC14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5224-3TC14 soft starter, 200-480 V, 20 A minimum setting, Trip Class 10A (default) / 10E / 20E, screw fixing, 306 x 185 x 203 mm (HxWxD).","salesMarkdown":"## 20 A minimum setting and trip class — what drives the motor start profile The 3RW5224-3TC14's minimum settable current is 20 A, which defines the lower bound of the motor full-load current it can protect. For higher-inertia loads like centrifuges or crushers, select Class 10E or 20E via the parameter menu — the longer trip time gives the motor headroom to accelerate without nuisance tripping. This means the same unit works on 230 V, 400 V, and 480 V systems without a hardware change — only the parameter set adjusts. ## Fieldbus portfolio — five protocols in one hardware variant This order code ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — no separate communication module purchase required. The PROFINET interface supports PROFIenergy, which allows the controller to put the starter into an energy-saving idle state during production pauses. ## Mounting and clearance — screw-fixed, not DIN-rail Fastening is by screw fixing — the unit does not snap onto a DIN rail. Plan for four M6 screws into a backplate rated for the 306 × 185 × 203 mm envelope. Minimum clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 0 mm backward, and 5 mm at each side. These gaps are for ventilation and arc-flash containment; crowding them derates the continuous current. ## Active production — no LTB, no obsolescence signal No pin-compatible successor exists because none is needed. ## Approvals and ambient derating for global installations Carries CE, UL, and CSA marks — accepted in European, US, and Canadian installations without additional agency review. In a 50 °C panel, expect to reduce the motor full-load current setting proportionally per the derating curve.","metaTitle":"Siemens 3RW5224-3TC14 Soft Starter, 20A min, 200-480V","metaDescription":"Siemens 3RW5224-3TC14 SIRIUS soft starter, 200-480V, 20A min setting, Trip Class 10A/10E/20E. Active production, quoted to order. CE, UL, CSA approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","title":"3RW5224-3TC14","Height":"306 mm","Minimum":"20 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 480 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 47 A, 110-250 V AC spring-type terminals Thermistor input","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"No","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"81.4 A","at 50 °C rated value":"72 A","at 60 °C rated value":"62.7 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"26 W","at 50 °C after startup":"24 W","at 60 °C after startup":"23 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"0","Number Of Digital Inputs":"1","Weight Without Packaging":"5.2 kg","at 40 °C during startup":"606 W","at 50 °C during startup":"522 W","at 60 °C during startup":"438 W","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"11 kW","at 400 V at 40 °C rated value":"22 kW","At Inside-Delta Circuit Minimum":"34.6 A","Width Of Connection Bar Maximum":"25 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"10 hp","at 220/230 V at 50 °C rated value":"10 hp","at 460/480 V at 50 °C rated value":"30 hp","of circuit breaker usable at 400 V":"3RV2032-4JA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4JA10; Type of coordination 1, Iq = 10 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","at the digital inputs at AC maximum":"100 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 400 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","At Rotary Coding Switch On Switch Position 1":"20 A","At Rotary Coding Switch On Switch Position 2":"21.8 A","At Rotary Coding Switch On Switch Position 3":"23.6 A","At Rotary Coding Switch On Switch Position 4":"25.4 A","At Rotary Coding Switch On Switch Position 5":"27.2 A","At Rotary Coding Switch On Switch Position 6":"29 A","At Rotary Coding Switch On Switch Position 7":"30.8 A","At Rotary Coding Switch On Switch Position 8":"32.6 A","At Rotary Coding Switch On Switch Position 9":"34.4 A","At Rotary Coding Switch On Switch Position 10":"36.2 A","At Rotary Coding Switch On Switch Position 11":"38 A","At Rotary Coding Switch On Switch Position 12":"39.8 A","At Rotary Coding Switch On Switch Position 13":"41.6 A","At Rotary Coding Switch On Switch Position 14":"43.4 A","At Rotary Coding Switch On Switch Position 15":"45.2 A","At Rotary Coding Switch On Switch Position 16":"47 A","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"75 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","Locked-Rotor Current At Close Of Bypass Contact Maximum":"2.5 A","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4RA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4RA10; Type of coordination 1, Iq = 10 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"34.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"37.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"40.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"44 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"47.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"50.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"53.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"56.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"59.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"62.7 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"65.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"68.9 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"72.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"75.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"78.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"81.4 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8024-1; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1021-2; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","at AWG cables for main contacts for box terminal using the front clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dd2f3fa974a43efb2255ca0e07e87584.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830534&mlfb=3RW5224-3TC14"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 3RW5224-3TC14?","answer":"The unit carries CE marking, UL approval, and CSA approval. These cover the European Low Voltage Directive, US National Electrical Code, and Canadian Electrical Code installations. RoHS and REACH declarations are standard Siemens documentation available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5224-3TC14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5224-3TC14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}