{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5225-3AC14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5225-3AC14","canonicalUrl":"https://aoctrl.com/siemens/3RW5225-3AC14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5225-3AC14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5225-3AC14 soft starter, 25.5 A minimum setting, 200-480 V rated voltage, trip class 10A/10E/20E per IEC 60947-4-2, multi-protocol onboard, screw fixing, 306 x 185 x 203 mm.","salesMarkdown":"## Active production — what that means for procurement The 3RW5225-3AC14 carries a current lifecycle stage, meaning Siemens still manufactures it as a standard catalog item. No last-time-buy window or phase-out notice is in effect. ## Trip class and motor starting duty The unit also offers selectable 10E and 20E classes for higher-inertia loads like centrifuges or crushers that need a longer acceleration ramp. The minimum settable current is 25.5 A, so motors with a full-load current below that value require a smaller frame size. The rated voltage range of 200–480 V covers the common low-voltage supplies worldwide without a hardware tap change. ## Onboard communications — no extra module needed PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard are all built into the base unit. This eliminates the cost and panel space of a separate communication module for most industrial networks. PROFIenergy is supported when used with the PROFINET standard communication module, enabling energy management functions during idle periods. ## Soft Torque and Pump Ramp Down — mechanical stress reduction Soft Torque reduces the initial current spike and mechanical shock on start, which extends the life of belts, gears, and couplings. Pump Ramp Down provides a controlled deceleration on stop, preventing water hammer in pumping systems. ## Mounting and panel integration Mounting is by screw fixing, not DIN-rail clip. The dimensions are 306 mm height, 185 mm width, and 203 mm depth. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward. The mounting position allows ±10° rotation and can be tilted forward or backward on a vertical surface. UL, CSA, and CE markings are all present, so the unit is accepted in North American and European installations without additional certification work. Shock resistance is rated at 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms. The service factor is 1.0.","metaTitle":"Siemens 3RW5225-3AC14 SIRIUS Soft Starter, 25.5 A, 200-480 V","metaDescription":"Siemens 3RW5225-3AC14 SIRIUS soft starter, 25.5 A minimum, 200-480 V, trip class 10A/10E/20E. Active production, UL/CSA/CE. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","title":"3RW5225-3AC14","Height":"306 mm","Minimum":"25.5 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 480 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 63 A, 110-250 V AC spring-type terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"109 A","at 50 °C rated value":"96 A","at 60 °C rated value":"87.5 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"31 W","at 50 °C after startup":"29 W","at 60 °C after startup":"27 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"5.6 kg","at 40 °C during startup":"882 W","at 50 °C during startup":"744 W","at 60 °C during startup":"659 W","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"18.5 kW","at 400 V at 40 °C rated value":"30 kW","At Inside-Delta Circuit Minimum":"44.2 A","Width Of Connection Bar Maximum":"25 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3830-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"15 hp","at 220/230 V at 50 °C rated value":"20 hp","at 460/480 V at 50 °C rated value":"40 hp","of circuit breaker usable at 400 V":"3VA2163-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2163-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","at the digital inputs at AC maximum":"100 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 400 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","At Rotary Coding Switch On Switch Position 1":"25.5 A","At Rotary Coding Switch On Switch Position 2":"28 A","At Rotary Coding Switch On Switch Position 3":"30.5 A","At Rotary Coding Switch On Switch Position 4":"33 A","At Rotary Coding Switch On Switch Position 5":"35.5 A","At Rotary Coding Switch On Switch Position 6":"38 A","At Rotary Coding Switch On Switch Position 7":"40.5 A","At Rotary Coding Switch On Switch Position 8":"43 A","At Rotary Coding Switch On Switch Position 9":"45.5 A","At Rotary Coding Switch On Switch Position 10":"48 A","At Rotary Coding Switch On Switch Position 11":"50.5 A","At Rotary Coding Switch On Switch Position 12":"53 A","At Rotary Coding Switch On Switch Position 13":"55.5 A","At Rotary Coding Switch On Switch Position 14":"58 A","At Rotary Coding Switch On Switch Position 15":"60.5 A","At Rotary Coding Switch On Switch Position 16":"63 A","Type Of Voltage Of The Control Supply Voltage":"AC","Holding Current In Bypass Operation Rated Value":"75 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Inrush Current By Closing The Bypass Contacts Maximum":"2.5 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3830-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"44.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"48.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"52.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"57.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"61.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"65.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"70.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"74.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"78.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"83.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"87.5 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"91.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"96.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"100 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"105 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"109 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8024-1; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1022-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/71abf7e63483907872371e4e83a5c321.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830546&mlfb=3RW5225-3AC14"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5225-3AC14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5225-3AC14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}