{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5226-1TC15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5226-1TC15","canonicalUrl":"https://aoctrl.com/siemens/3RW5226-1TC15","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5226-1TC15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5226-1TC15 soft starter, 32 A minimum, 200-600 V rated voltage, CLASS 10A/10E/20E trip class per IEC 60947-4-2, screw fixing, 306 x 185 x 203 mm.","salesMarkdown":"## SIRIUS 3RW5226-1TC15 — 32 A soft starter with multi-protocol fieldbus The Siemens 3RW5226-1TC15 is a SIRIUS hybrid switching device — a soft starter rated for motor starting duty with a minimum settable current of 32 A and a rated voltage range of 200 to 600 V. Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2, which governs the allowable motor starting time before the overload protection trips — CLASS 10A suits normal-start loads like pumps and fans, while CLASS 20E handles higher-inertia loads such as centrifuges. On-board fieldbus includes PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard with PROFIenergy support, so the starter integrates directly into a PLC-based control architecture without an external gateway. ## Mounting, clearance, and thermal derating Fastened by screw fixing to a vertical mounting surface, the unit can be rotated ±90° or tilted ±22.5° front-to-back, giving panel builders flexibility in orientation within the enclosure. Required clearances: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, and 0 mm backwards — these ensure adequate airflow for the internal heatsink and prevent thermal stacking between adjacent devices. ## Active production — lifecycle and approvals Carries UL, CSA, and CE marking — accepted in North American and European installations without additional certification delays. Shock resistance is 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms — relevant for applications on mobile equipment or near vibrating machinery.","metaTitle":"Siemens 3RW5226-1TC15 SIRIUS Soft Starter, 32 A, 200-600 V","metaDescription":"Siemens 3RW5226-1TC15 SIRIUS soft starter, 32 A minimum, 200-600 V rated voltage, CLASS 10A/10E/20E trip class. Active production, UL/CSA/CE approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","title":"3RW5226-1TC15","Height":"306 mm","Minimum":"32 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 77 A, 110-250 V AC Screw terminals Thermistor input","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"No","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"133 A","at 50 °C rated value":"118 A","at 60 °C rated value":"107 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"35 W","at 50 °C after startup":"32 W","at 60 °C after startup":"31 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"0","Number Of Digital Inputs":"1","Weight Without Packaging":"5.6 kg","at 40 °C during startup":"1 107 W","at 50 °C during startup":"933 W","at 60 °C during startup":"826 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"22 kW","at 400 V at 40 °C rated value":"37 kW","at 500 V at 40 °C rated value":"45 kW","At Inside-Delta Circuit Minimum":"55.4 A","Width Of Connection Bar Maximum":"25 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3132-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"20 hp","at 220/230 V at 50 °C rated value":"25 hp","at 460/480 V at 50 °C rated value":"50 hp","at 575/600 V at 50 °C rated value":"60 hp","of circuit breaker usable at 400 V":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","at the digital inputs at AC maximum":"100 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 800 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","At Rotary Coding Switch On Switch Position 1":"32 A","At Rotary Coding Switch On Switch Position 2":"35 A","At Rotary Coding Switch On Switch Position 3":"38 A","At Rotary Coding Switch On Switch Position 4":"41 A","At Rotary Coding Switch On Switch Position 5":"44 A","At Rotary Coding Switch On Switch Position 6":"47 A","At Rotary Coding Switch On Switch Position 7":"50 A","At Rotary Coding Switch On Switch Position 8":"53 A","At Rotary Coding Switch On Switch Position 9":"56 A","At Rotary Coding Switch On Switch Position 10":"59 A","At Rotary Coding Switch On Switch Position 11":"62 A","At Rotary Coding Switch On Switch Position 12":"65 A","At Rotary Coding Switch On Switch Position 13":"68 A","At Rotary Coding Switch On Switch Position 14":"71 A","At Rotary Coding Switch On Switch Position 15":"74 A","At Rotary Coding Switch On Switch Position 16":"77 A","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"75 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","Locked-Rotor Current At Close Of Bypass Contact Maximum":"2.5 A","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3132-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"55.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"60.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"65.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"71 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"76.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"81.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"86.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"91.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"97 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"102 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"107 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"113 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"118 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"123 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"128 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"133 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8024-1; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1224-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","at AWG cables for main contacts for box terminal using the front clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/06fa4666ab4fffe0db8fe643b5d7587e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830559&mlfb=3RW5226-1TC15"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5226-1TC15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5226-1TC15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}