{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5226-3AC05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5226-3AC05","canonicalUrl":"https://aoctrl.com/siemens/3RW5226-3AC05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5226-3AC05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5226-3AC05 soft starter, 32 A minimum, 200-600 V, Class 10A trip, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, 306 x 185 x 203 mm.","salesMarkdown":"## Motor starting duty and trip class selection The 3RW5226-3AC05 is configured with a default trip class of CLASS 10A per IEC 60947-4-2, with selectable CLASS 10E and CLASS 20E for heavier starting profiles. CLASS 10A limits the rotor locked current duration to 10 seconds at the set current limit — a fit for centrifugal pumps and fans where the load torque rises with speed squared, not for high-inertia conveyors that need the extended 20E window. The minimum settable current is 32 A, which sets the floor for the motor FLC the starter can protect. Below that, the overload curve cannot be calibrated to the motor's thermal damage curve, so the driven motor must draw at least 32 A at full load. ## Communications and control integration This SIRIUS soft starter carries onboard PROFIBUS DP, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard — all five fieldbus protocols are native, no add-on module required for the common plant-floor networks. The PROFINET interface also supports PROFIenergy for coordinated load shedding during production pauses. The analog output is factory-set to 4-20 mA, parameterizable to 0-10 V through the High Feature HMI accessory. This gives the DCS or PLC a live motor current signal without a separate CT loop. ## Mounting dimensions and panel clearance The unit measures 306 mm high, 185 mm wide, and 203 mm deep, with screw fixing to the mounting surface. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm to the side, and 0 mm backward — the back face can sit flush against the panel backplate. Mounting position allows vertical surface orientation with ±90° rotation and ±22.5° tilt forward/back. The 15 g shock resistance at 11 ms holds the contactor closed through a fault event, though above 12 g potential contact lifting is noted — relevant for installations near rotating machinery or on mobile equipment. ## Operating temperature and derating In a non-ventilated enclosure or near a heat source like a drive, the internal temperature rise must be calculated against the 40 °C threshold — above that, the continuous current rating is reduced per the derating curve in the product documentation.","metaTitle":"Siemens 3RW5226-3AC05 Soft Starter, 32 A, 200-600 V, SIRIUS","metaDescription":"Siemens 3RW5226-3AC05 SIRIUS soft starter, 32 A minimum, 200-600 V, Class 10A/10E/20E trip, PROFIBUS/Modbus/EtherNet/IP. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","title":"3RW5226-3AC05","Height":"306 mm","Minimum":"32 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 77 A, 24 V AC/DC spring-type terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"133 A","at 50 °C rated value":"118 A","at 60 °C rated value":"107 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"35 W","at 50 °C after startup":"32 W","at 60 °C after startup":"31 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"5.6 kg","at 40 °C during startup":"1 107 W","at 50 °C during startup":"933 W","at 60 °C during startup":"826 W","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"22 kW","at 400 V at 40 °C rated value":"37 kW","at 500 V at 40 °C rated value":"45 kW","At Inside-Delta Circuit Minimum":"55.4 A","Width Of Connection Bar Maximum":"25 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3132-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"20 hp","at 220/230 V at 50 °C rated value":"25 hp","at 460/480 V at 50 °C rated value":"50 hp","at 575/600 V at 50 °C rated value":"60 hp","of circuit breaker usable at 400 V":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","at the digital inputs at AC maximum":"100 m","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 800 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","At Rotary Coding Switch On Switch Position 1":"32 A","At Rotary Coding Switch On Switch Position 2":"35 A","At Rotary Coding Switch On Switch Position 3":"38 A","At Rotary Coding Switch On Switch Position 4":"41 A","At Rotary Coding Switch On Switch Position 5":"44 A","At Rotary Coding Switch On Switch Position 6":"47 A","At Rotary Coding Switch On Switch Position 7":"50 A","At Rotary Coding Switch On Switch Position 8":"53 A","At Rotary Coding Switch On Switch Position 9":"56 A","At Rotary Coding Switch On Switch Position 10":"59 A","At Rotary Coding Switch On Switch Position 11":"62 A","At Rotary Coding Switch On Switch Position 12":"65 A","At Rotary Coding Switch On Switch Position 13":"68 A","At Rotary Coding Switch On Switch Position 14":"71 A","At Rotary Coding Switch On Switch Position 15":"74 A","At Rotary Coding Switch On Switch Position 16":"77 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Holding Current In Bypass Operation Rated Value":"380 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","Locked-Rotor Current At Close Of Bypass Contact Maximum":"7.6 A","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3132-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"55.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"60.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"65.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"71 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"76.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"81.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"86.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"91.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"97 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"102 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"107 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"113 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"118 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"123 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"128 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"133 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8024-1; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1224-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","at AWG cables for main contacts for box terminal using the front clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f211758a8d234b5b35134604681355aa.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830561&mlfb=3RW5226-3AC05"},"ai":{"faq":[{"question":"What compliance approvals does the 3RW5226-3AC05 carry?","answer":"CE marking, UL approval, and CSA approval are all confirmed on the product record. The degree of pollution is rated 3 per IEC 60947-4-2, which means the device is suitable for industrial environments with conductive pollution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5226-3AC05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5226-3AC05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}