{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5226-3TC14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5226-3TC14","canonicalUrl":"https://aoctrl.com/siemens/3RW5226-3TC14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5226-3TC14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS soft starter, 3RW5226-3TC14, 200-480 V, 32 A minimum, Trip Class 10A (default) / 10E / 20E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, UL, CSA, CE.","salesMarkdown":"The 3RW5226-3TC14 is a SIRIUS hybrid soft starter rated for motor loads between 32 A minimum and the full-load current you set within the 200-480 VAC range. The trip class defaults to CLASS 10A per IEC 60947-4-2. The unit ships with screw fixing for panel mounting. It measures 306 mm tall by 185 mm wide by 203 mm deep, so plan your enclosure backplate real estate accordingly. Fieldbus support is broad: PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP are all on the table. That means it drops into most control architectures without a gateway — handy when you're retrofitting a line and the PLC room already speaks one of those protocols. Approvals include UL, CSA, and CE marking, so it's accepted across North American and European panels without a separate certification chase. If your machine ships to a site that demands one of those marks, the nameplate already carries it. That's forgiving for enclosures where the backplate isn't perfectly plumb. Minimum clearances around the unit: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, 0 mm backwards. Stacking it tight against the back wall is fine, but give it breathing room above and below for convection. The soft starter includes Soft Torque and Pump Ramp Down features — useful for centrifugal pumps where you want to avoid pressure surges on start and water hammer on stop. It also supports auto-reset and remote reset by cycling the control supply voltage. An error logbook is available but only with special accessories. Firmware updates are supported, and PROFIenergy is functional when paired with the PROFINET communication module.","metaTitle":"Siemens 3RW5226-3TC14 SIRIUS Soft Starter, 32 A min","metaDescription":"Siemens 3RW5226-3TC14 SIRIUS soft starter, 32 A min, 200-480 V, Trip Class 10A/10E/20E. Supports PROFIBUS, Modbus RTU/TCP, EtherNet/IP. UL/CSA/CE.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","Height":"306 mm","Minimum":"32 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 480 V","Soft Torque":"Yes","UL approval":"Yes","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"No","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"133 A","at 50 °C rated value":"118 A","at 60 °C rated value":"107 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"35 W","at 50 °C after startup":"32 W","at 60 °C after startup":"31 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"0","Number Of Digital Inputs":"1","Weight Without Packaging":"5.6 kg","at 40 °C during startup":"1 107 W","at 50 °C during startup":"933 W","at 60 °C during startup":"826 W","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"22 kW","at 400 V at 40 °C rated value":"37 kW","At Inside-Delta Circuit Minimum":"55.4 A","Width Of Connection Bar Maximum":"25 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3132-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"20 hp","at 220/230 V at 50 °C rated value":"25 hp","at 460/480 V at 50 °C rated value":"50 hp","of circuit breaker usable at 400 V":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","at the digital inputs at AC maximum":"100 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 400 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","At Rotary Coding Switch On Switch Position 1":"32 A","At Rotary Coding Switch On Switch Position 2":"35 A","At Rotary Coding Switch On Switch Position 3":"38 A","At Rotary Coding Switch On Switch Position 4":"41 A","At Rotary Coding Switch On Switch Position 5":"44 A","At Rotary Coding Switch On Switch Position 6":"47 A","At Rotary Coding Switch On Switch Position 7":"50 A","At Rotary Coding Switch On Switch Position 8":"53 A","At Rotary Coding Switch On Switch Position 9":"56 A","At Rotary Coding Switch On Switch Position 10":"59 A","At Rotary Coding Switch On Switch Position 11":"62 A","At Rotary Coding Switch On Switch Position 12":"65 A","At Rotary Coding Switch On Switch Position 13":"68 A","At Rotary Coding Switch On Switch Position 14":"71 A","At Rotary Coding Switch On Switch Position 15":"74 A","At Rotary Coding Switch On Switch Position 16":"77 A","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"75 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","Locked-Rotor Current At Close Of Bypass Contact Maximum":"2.5 A","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3132-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"55.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"60.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"65.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"71 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"76.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"81.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"86.6 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"91.8 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"97 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"102 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"107 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"113 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"118 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"123 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"128 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"133 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8024-1; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1224-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","at AWG cables for main contacts for box terminal using the front clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830566&mlfb=3RW5226-3TC14","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW5226-3TC14/alternatives.json"},"ai":{"faq":[{"question":"Does the 3RW5226-3TC14 support Modbus TCP communication?","answer":"Yes, the 3RW5226-3TC14 supports Modbus TCP alongside Modbus RTU, PROFIBUS, and EtherNet/IP. You can integrate it directly into most control networks without an external gateway."},{"question":"What is the difference between 3RW5226-3TC14 and 3RW5226-3TC13?","answer":"The difference is in the fieldbus interface. The 3RW5226-3TC14 supports PROFIBUS, Modbus RTU/TCP, and EtherNet/IP, while the 3RW5226-3TC13 typically has a different communication profile. Both share the same power section ratings (32 A minimum, 200-480 V, Trip Class 10A/10E/20E). Check your control network before ordering."},{"question":"What is the price of Siemens 3RW5226-3TC14 soft starter?","answer":"Pricing for the 3RW5226-3TC14 is confirmed at quote time based on current market conditions and quantity. Submit an RFQ for a firm price — we source it to order through our distribution network."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5226-3TC14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5226-3TC14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}