{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5227-3AC05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5227-3AC05","canonicalUrl":"https://aoctrl.com/siemens/3RW5227-3AC05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5227-3AC05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5227-3AC05 soft starter, 40.5 A minimum, 200-600 V, trip class 10A/10E/20E, multi-protocol fieldbus, screw fixing, 306 x 185 x 203 mm.","salesMarkdown":"The Siemens 3RW5227-3AC05 is a SIRIUS soft starter rated for a minimum motor current of 40.5 A across a voltage range of 200 to 600 V, meaning it handles standard low-voltage induction motors in that current band — not a 10 A pump, not a 200 A conveyor. The trip class defaults to CLASS 10A per IEC 60947-4-2, which limits the thermal stress during start to 10 seconds for a 7.5x locked-rotor current; you can reparameterize to 10E or 20E if the load profile (high-inertia fan, centrifuge) needs a longer ramp. The 40.5 A minimum is the smallest settable current, so it won't protect a motor drawing less than that — size down for fractional-horsepower loads. Mounting is screw-fixed on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back, which gives flexibility in a crowded panel but still demands a 306 mm height, 185 mm width, and 203 mm depth footprint. ## Fieldbus and control integration This soft starter carries onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard (with PROFIenergy support via a PROFINET communication module). That means it drops into most common fieldbus architectures without an external gateway — a controls integrator can map the starter's status and diagnostics directly into the PLC tag database. The analog output defaults to 4-20 mA but can be parameterized to 0-10 V through the High Feature HMI accessory, useful for feeding a remote meter or an analog input card that expects voltage. Remote reset is achieved by cycling the control supply voltage off and on — a standard field-service technique that avoids a physical pushbutton on the door. The error logbook is available only with special accessories, so if you need fault-history retrieval, factor that accessory into the BOM now rather than chasing it later.","metaTitle":"Siemens 3RW5227-3AC05 Soft Starter, 40.5 A, 200-600 V","metaDescription":"Siemens 3RW5227-3AC05 SIRIUS soft starter, 40.5 A minimum, 200-600 V, trip class 10A/10E/20E. Supports PROFIBUS, Modbus RTU/TCP, EtherNet/IP.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"203 mm","Width":"185 mm","Height":"306 mm","Mounting":"screw fixing","Trip Class":"CLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2","Product Status":"Active","Service Factor":"1","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/09c2b6c17fa224ff909e784bb75c533e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830577&mlfb=3RW5227-3AC05","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW5227-3AC05/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5227-3AC05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5227-3AC05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}