{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5227-3AC05","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5227-3AC05","canonicalUrl":"https://aoctrl.com/siemens/3RW5227-3AC05","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5227-3AC05","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5227-3AC05 soft starter, 40.5 A minimum, 200-600 V, trip class 10A/10E/20E, multi-protocol fieldbus, screw fixing, 306 x 185 x 203 mm.","salesMarkdown":"The Siemens 3RW5227-3AC05 is a SIRIUS soft starter rated for a minimum motor current of 40.5 A across a voltage range of 200 to 600 V, meaning it handles standard low-voltage induction motors in that current band — not a 10 A pump, not a 200 A conveyor. The trip class defaults to CLASS 10A per IEC 60947-4-2, which limits the thermal stress during start to 10 seconds for a 7.5x locked-rotor current; you can reparameterize to 10E or 20E if the load profile (high-inertia fan, centrifuge) needs a longer ramp. The 40.5 A minimum is the smallest settable current, so it won't protect a motor drawing less than that — size down for fractional-horsepower loads. Mounting is screw-fixed on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back, which gives flexibility in a crowded panel but still demands a 306 mm height, 185 mm width, and 203 mm depth footprint. ## Fieldbus and control integration This soft starter carries onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard (with PROFIenergy support via a PROFINET communication module). That means it drops into most common fieldbus architectures without an external gateway — a controls integrator can map the starter's status and diagnostics directly into the PLC tag database. The analog output defaults to 4-20 mA but can be parameterized to 0-10 V through the High Feature HMI accessory, useful for feeding a remote meter or an analog input card that expects voltage. Remote reset is achieved by cycling the control supply voltage off and on — a standard field-service technique that avoids a physical pushbutton on the door. The error logbook is available only with special accessories, so if you need fault-history retrieval, factor that accessory into the BOM now rather than chasing it later.","metaTitle":"Siemens 3RW5227-3AC05 Soft Starter, 40.5 A, 200-600 V","metaDescription":"Siemens 3RW5227-3AC05 SIRIUS soft starter, 40.5 A minimum, 200-600 V, trip class 10A/10E/20E. Supports PROFIBUS, Modbus RTU/TCP, EtherNet/IP.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"185 mm","title":"3RW5227-3AC05","Height":"306 mm","Minimum":"40.5 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 600 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 93 A, 24 V AC/DC spring-type terminals Analog output","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"161 A","at 50 °C rated value":"143 A","at 60 °C rated value":"131 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"40 W","at 50 °C after startup":"37 W","at 60 °C after startup":"35 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"1","Number Of Digital Inputs":"1","Weight Without Packaging":"6.9 kg","at 40 °C during startup":"1 270 W","at 50 °C during startup":"1 077 W","at 60 °C during startup":"959 W","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Electronic motor overload protection","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"22 kW","at 400 V at 40 °C rated value":"45 kW","at 500 V at 40 °C rated value":"55 kW","At Inside-Delta Circuit Minimum":"70.1 A","Width Of Connection Bar Maximum":"25 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3136-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"25 hp","at 220/230 V at 50 °C rated value":"30 hp","at 460/480 V at 50 °C rated value":"60 hp","at 575/600 V at 50 °C rated value":"75 hp","of circuit breaker usable at 400 V":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 15 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2216-7MN32-0AA0; Type of coordination 1, Iq = 10 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","at the digital inputs at AC maximum":"100 m","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 800 V","Evaluation Of Thermistor Motor Protection":"No","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","At Rotary Coding Switch On Switch Position 1":"40.5 A","At Rotary Coding Switch On Switch Position 2":"44 A","At Rotary Coding Switch On Switch Position 3":"47.5 A","At Rotary Coding Switch On Switch Position 4":"51 A","At Rotary Coding Switch On Switch Position 5":"54.5 A","At Rotary Coding Switch On Switch Position 6":"58 A","At Rotary Coding Switch On Switch Position 7":"61.5 A","At Rotary Coding Switch On Switch Position 8":"65 A","At Rotary Coding Switch On Switch Position 9":"68.5 A","At Rotary Coding Switch On Switch Position 10":"72 A","At Rotary Coding Switch On Switch Position 11":"75.5 A","At Rotary Coding Switch On Switch Position 12":"79 A","At Rotary Coding Switch On Switch Position 13":"82.5 A","At Rotary Coding Switch On Switch Position 14":"86 A","At Rotary Coding Switch On Switch Position 15":"89.5 A","At Rotary Coding Switch On Switch Position 16":"93 A","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Holding Current In Bypass Operation Rated Value":"380 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"160 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","Locked-Rotor Current At Close Of Bypass Contact Maximum":"7.6 A","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3136-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2220-7MN32-0AA0; Type of coordination 1, Iq = 15 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2220-7MN32-0AA0; Type of coordination 1, Iq = 10 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"3.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"70.1 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"76.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"82.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"88.3 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"94.4 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"100 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"107 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"113 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"119 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"125 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"131 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"137 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"143 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"149 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"155 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"161 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE4124; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"12.1 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1224-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","at AWG cables for main contacts for box terminal using the front clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/09c2b6c17fa224ff909e784bb75c533e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830577&mlfb=3RW5227-3AC05"},"ai":{"faq":[{"question":"What voltage range does 3RW5227-3AC05 cover?","answer":"The 3RW5227-3AC05 covers a rated voltage range of 200 to 600 V, making it suitable for standard low-voltage three-phase motor applications across most industrial mains voltages."},{"question":"Does 3RW5227-3AC05 support Modbus TCP?","answer":"Yes, the 3RW5227-3AC05 supports Modbus TCP onboard, along with PROFIBUS, Modbus RTU, EtherNet/IP, and PROFINET standard — no external gateway needed for most common fieldbus architectures."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5227-3AC05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5227-3AC05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}