{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5234-2TC15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5234-2TC15","canonicalUrl":"https://aoctrl.com/siemens/3RW5234-2TC15","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5234-2TC15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5234-2TC15 soft starter, 53 A minimum, 200-600 V, Trip Class 10A/10E/20E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP.","salesMarkdown":"## 53 A minimum, Trip Class 10A — what that means for motor starting The Siemens 3RW5234-2TC15 is a SIRIUS soft starter rated for a minimum motor current of 53 A at 200-600 V, with Trip Class 10A as the default setting — meaning it will disconnect the motor if the start takes longer than 10 seconds at six times the set current, per IEC 60947-4-2. For applications requiring a longer acceleration window, you can switch to Class 10E or 20E, which extends the thermal curve to 20 seconds at 6× Ie. This is the parameter that governs whether the starter trips on a heavy start (high-inertia fan, loaded conveyor) or holds through it. The 53 A minimum floor means this unit is sized for motors drawing at least that current at full load; it will not adjust down to fractional loads. If your BOM calls for a 30 A motor, this is the wrong frame. The 200-600 V operating range covers standard 400 V three-phase industrial supplies across 50/60 Hz. ## Fieldbus onboard — PROFIBUS, Modbus, EtherNet/IP This soft starter ships with PROFIBUS onboard — no option card needed for that protocol. It also supports Modbus RTU, Modbus TCP, and EtherNet/IP natively, so it drops into most automation architectures without a gateway. If your line runs PROFINET, the unit supports it as well, with PROFIenergy available when paired with the PROFINET communication module. For commissioning, the firmware is field-updatable, and an error logbook is accessible via special accessories. The HMI-High Feature is not present on this variant, so parameterization is done through the fieldbus or a connected panel. ## Mounting and clearance — fits a standard enclosure The 3RW5234-2TC15 measures 306 mm high, 185 mm wide, and 203 mm deep. It mounts via screw fixing on a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. Minimum clearances: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, 0 mm backward. These are the numbers your panel designer needs for airflow and cable bend radius — the backward clearance of zero means it can sit flush against a backplate.","metaTitle":"Siemens 3RW5234-2TC15 SIRIUS Soft Starter, 53 A","metaDescription":"Siemens 3RW5234-2TC15 SIRIUS soft starter, 53 A minimum, 200-600 V, Trip Class 10A/10E/20E. PROFIBUS onboard, Modbus RTU/TCP, EtherNet/IP.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"203 mm","Width":"185 mm","Height":"306 mm","Mounting":"screw fixing","Trip Class":"CLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2","Product Status":"Active","Service Factor":"1","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ddc0bad5f5f8b20d2ef0f9c090fd9d1c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830591&mlfb=3RW5234-2TC15","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW5234-2TC15/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5234-2TC15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5234-2TC15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}