{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5245-6TC14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5245-6TC14","canonicalUrl":"https://aoctrl.com/siemens/3RW5245-6TC14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5245-6TC14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5245-6TC14 soft starter, 135 A minimum rated current, 200-480 V operating voltage, Trip Class 10A/10E/20E per IEC 60947-4-2, screw fixing, 393 x 210 x 203 mm.","salesMarkdown":"## Motor fit — the three specs that decide it The 3RW5245-6TC14 is a SIRIUS soft starter rated for a minimum current of 135 A at an operating voltage of 200-480 V. That 135 A floor is the key number for motor matching — it sets the smallest motor this unit can soft-start without dropping below the minimum load threshold of 15% relative to the smallest settable Ie. Trip Class is selectable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2. Class 10A is the standard for standard-start applications; Class 20E gives you a longer thermal memory for high-inertia loads where the start takes longer. Pick the class that matches your motor's acceleration time and the upstream protection coordination. ## Fieldbus and control — what connects where This soft starter ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard communication. That means it drops into most common industrial networks without an extra gateway module — one part number covers the fieldbus slice. PROFIenergy is supported in connection with the PROFINET Standard communication module, which lets the drive participate in energy management profiles during idle periods. The unit also supports firmware updates in the field. Control features include Soft Torque for gentle acceleration, Pump Ramp Down for controlled deceleration in pumping applications, auto-RESET, and Remote Reset by cycling the control supply voltage. No analog output or torque control on this variant. ## Mounting and clearances — panel fit Fastening method is screw fixing, with a vertical mounting surface that can be rotated ±90° or tilted ±22.5° front-to-back. Dimensions are 393 mm height, 210 mm width, 203 mm depth — that's a substantial footprint, so check your gland plate and DIN-rail backplane before committing. Required clearances: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the sides. The zero backwards clearance is notable — you can mount it flush against the back panel, which saves depth in a tight enclosure. ## Environmental and approvals Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms with potential contact lifting — relevant if this sits near a press or conveyor with repetitive impacts. Approvals include UL, CSA, and CE marking — covers North American and European installations without additional certification paperwork.","metaTitle":"Siemens 3RW5245-6TC14 SIRIUS Soft Starter, 135 A, 200-480 V","metaDescription":"Siemens 3RW5245-6TC14 SIRIUS soft starter, 135 A minimum, 200-480 V, Trip Class 10A/10E/20E. UL, CSA, CE. Current production — quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Depth":"203 mm","Width":"210 mm","title":"3RW5245-6TC14","Height":"393 mm","Minimum":"135 A","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard communication module","Rated Value":"200 ... 480 V","Soft Torque":"Yes","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 315 A, 110-250 V AC Screw terminals Thermistor input","CSA approval":"Yes","Remote Reset":"Yes; By turning off the control supply voltage","Analog Output":"No","Error Logbook":"Yes; Only in conjunction with special accessories","Pump Ramp Down":"Yes","Service Factor":"1","Torque Control":"No","Firmware Update":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"No","Minimum Load [%]":"15 %; Relative to smallest settable Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 12 g / 11 ms with potential contact lifting","Mounting Position":"with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Not Parameterizable":"2","Product Designation":"Soft starter","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"30 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm to 6 Hz; 2g to 500 Hz","Ramp-Down (Soft Stop)":"Yes","at 40 °C rated value":"546 A","at 50 °C rated value":"483 A","at 60 °C rated value":"442 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 changeover contact (CO)","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"107 W","at 50 °C after startup":"96 W","at 60 °C after startup":"89 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","For Main Current Circuit":"busbar connection","Number Of Analog Outputs":"0","Number Of Digital Inputs":"1","Weight Without Packaging":"9.9 kg","at 40 °C during startup":"5 350 W","at 50 °C during startup":"4 471 W","at 60 °C during startup":"3 934 W","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","is supported HMI-Standard":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Via Software Parameterizable":"No","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"in accordance with IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","of standard HMI module usable":"3RW5980-0HS00","Insulation Voltage Rated Value":"600 V","at 230 V at 40 °C rated value":"90 kW","at 400 V at 40 °C rated value":"160 kW","At Inside-Delta Circuit Minimum":"234 A","Width Of Connection Bar Maximum":"45 mm","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes; Only in conjunction with special accessories","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V","Start-Up Ramp Time Of Soft Starter":"0 ... 20 s","at 200/208 V at 50 °C rated value":"75 hp","at 220/230 V at 50 °C rated value":"100 hp","at 460/480 V at 50 °C rated value":"200 hp","of circuit breaker usable at 400 V":"3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","at the digital inputs at AC maximum":"100 m","of communication module Ethernet/IP":"3RW5980-0CE00","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"130 ... 700 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","For Main Contacts With Screw-Type Terminals":"124 ... 210 lbf·in","At Rotary Coding Switch On Switch Position 1":"135 A","At Rotary Coding Switch On Switch Position 2":"147 A","At Rotary Coding Switch On Switch Position 3":"159 A","At Rotary Coding Switch On Switch Position 4":"171 A","At Rotary Coding Switch On Switch Position 5":"183 A","At Rotary Coding Switch On Switch Position 6":"195 A","At Rotary Coding Switch On Switch Position 7":"207 A","At Rotary Coding Switch On Switch Position 8":"219 A","At Rotary Coding Switch On Switch Position 9":"231 A","for DIN cable lug for main contacts stranded":"2x (50 ... 240 mm²)","At Rotary Coding Switch On Switch Position 10":"243 A","At Rotary Coding Switch On Switch Position 11":"255 A","At Rotary Coding Switch On Switch Position 12":"267 A","At Rotary Coding Switch On Switch Position 13":"279 A","At Rotary Coding Switch On Switch Position 14":"291 A","At Rotary Coding Switch On Switch Position 15":"303 A","At Rotary Coding Switch On Switch Position 16":"315 A","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"100 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"30 mA","for DIN cable lug for main contacts finely stranded":"2x (70 ... 240 mm²)","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","Inrush Current By Closing The Bypass Contacts Maximum":"2.2 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"2x3NA3365-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2580-6HN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"12.2 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 1":"234 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 2":"255 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 3":"275 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 4":"296 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 5":"317 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 6":"338 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 7":"359 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 8":"379 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 9":"400 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 10":"421 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 11":"442 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 12":"462 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 13":"483 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 14":"504 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 15":"525 A","For Inside-Delta Circuit At Rotary Coding Switch On Switch Position 16":"546 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3336; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"2.2 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1334-2; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/95e19f7cb4332739448d31ec1d1fe63d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830678&mlfb=3RW5245-6TC14"},"ai":{"faq":[{"question":"What is 3RW5245-6TC14's listed depth?","answer":"The depth is 203 mm, with a width of 210 mm and height of 393 mm. Required backwards clearance is 0 mm, so it mounts flush against the back panel."},{"question":"What compliance documentation does Siemens provide for 3RW5245-6TC14?","answer":"The unit carries UL approval, CSA approval, and CE marking. These cover North American and European regulatory requirements for industrial control equipment."},{"question":"What trip classes are available on 3RW5245-6TC14?","answer":"Trip Class is selectable as CLASS 10A (default), 10E, or 20E, per IEC 60947-4-2. Class 10A suits standard starts; Class 20E handles longer acceleration times for high-inertia loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5245-6TC14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5245-6TC14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}