{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5513-1HA04","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5513-1HA04","canonicalUrl":"https://aoctrl.com/siemens/3RW5513-1HA04","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5513-1HA04","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5513-1HA04 soft starter, 200-480 V rated voltage, ATEX and IECEx certified, trip class 10A/10E/20E/30E, PROFIBUS/Modbus/EtherNet/IP, 152 x 170 x 275 mm.","salesMarkdown":"## What the 3RW5513-1HA04 brings to a motor start This soft starter covers the 200-480 V range, so it fits standard North American 480 V and European 400 V distribution without a transformer tap. Trip class is selectable from CLASS 10A through 30E per IEC 60947-4-2 — you can set it for a quick start on a light load or stretch the ramp for a high-inertia conveyor without tripping. It carries ATEX and IECEx certification, meaning it can sit in a Zone 2 or Zone 22 area if the rest of the panel is rated for it. Fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP — one part number covers the common industrial networks without a separate comms module. ## Mounting and panel fit The unit measures 152 mm deep by 170 mm wide by 275 mm tall — it needs 100 mm clearance above, 10 mm in front, 75 mm below, and 5 mm at the sides for airflow and wiring access. Terminals accept solid wire: two conductors at 1.0-2.5 mm² and two at 2.5-10 mm² per pole, using screw terminals. ## Control features that matter on the line Voltage ramp and pump ramp down are built in — the pump ramp down reduces water hammer on stop, which saves mechanical wear on check valves and piping. Torque control mode lets the starter regulate motor torque during acceleration, useful for soft-starting a loaded conveyor without shock. A breakaway pulse delivers a short torque burst to break loose a seized or high-friction load before the ramp begins. DC braking and combined braking are available for fast stops without a mechanical brake. The analog output can be configured as 4-20 mA or 0-10 V to feed motor current or torque to a PLC or panel meter. Service factor is 1.15, meaning the starter can handle a 15% continuous overload above the motor FLA rating without nuisance tripping. ## Diagnostics and commissioning aids An event list, error logbook, and trace function are all on board — you can review the last several start/stop events and fault conditions without a laptop. Accuracy class 5 per IEC 61557-12 means the current measurement is within 5% — adequate for protection and monitoring, not for billing-grade metering. Firmware updates are field-loadable, so you can apply Siemens patches without swapping hardware. Four parameterizable settings let you store different start profiles and switch between them for different motor loads on the same starter. ## Approvals and compliance documentation ATEX and IECEx certification means the documentation package includes the EU-type examination certificate and the IECEx certificate of conformity for hazardous-area approval.","metaTitle":"Siemens 3RW5513-1HA04 Soft Starter, 200-480V, ATEX","metaDescription":"Siemens 3RW5513-1HA04 soft starter, rated 200-480V, ATEX/IECEx certified, trip class 10A/10E/20E/30E. Active production, sourced per RFQ. UL, CSA, CE approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"152 mm","IECEx":"Yes","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5513-1HA04","Height":"275 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 480 V","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 13 A, 24 V AC/DC Screw terminals","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"Yes","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Product Designation":"Soft starter","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"22.5 A","at 50 °C rated value":"19.9 A","at 60 °C rated value":"18.2 A","Communication Function":"Yes","Digital Output Version":"3 normally-open contacts (NO) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"No","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"4 W","at 50 °C after startup":"3 W","at 60 °C after startup":"3 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","Emergency Operation Mode":"Yes","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"2.3 kg","at 40 °C during startup":"198 W","at 50 °C during startup":"166 W","at 60 °C during startup":"148 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.","Number Of Digital Outputs":"4","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at 40 °C rated value minimum":"2.5 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"480 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"3 kW","at 400 V at 40 °C rated value":"5.5 kW","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"2 hp","at 220/230 V at 50 °C rated value":"3 hp","at 460/480 V at 50 °C rated value":"7.5 hp","of circuit breaker usable at 400 V":"3RV2032-4TA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4TA10; Type of coordination 1, Iq = 18 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"3","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"18 ... 22 lbf·in","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"820 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"420 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"0.91 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 18 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"7.5 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8017-1; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"20 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1815-0; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$689.61","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fc9d4c2ae5eef90ddb747c8fdb9d6909.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830928&mlfb=3RW5513-1HA04"},"ai":{"faq":[{"question":"What trip classes does the 3RW5513-1HA04 support?","answer":"It supports CLASS 10A, 10E, 20E, and 30E per IEC 60947-4-2. The default is 10A or 10E, and you can select a higher class for high-inertia loads."},{"question":"Can the 3RW5513-1HA04 be used in a hazardous area?","answer":"Yes, it carries ATEX and IECEx certification, so it is suitable for use in Zone 2 or Zone 22 hazardous locations when installed per the certification conditions."},{"question":"What fieldbus protocols does the 3RW5513-1HA04 support?","answer":"It supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP — all integrated without a separate communication module."},{"question":"What compliance documentation does Siemens provide for the 3RW5513-1HA04?","answer":"The starter carries UL, CSA, and CE marking, plus ATEX and IECEx certificates for hazardous-area use. These cover the standard regulatory requirements for North America and Europe."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5513-1HA04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5513-1HA04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}