{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5513-1HF14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5513-1HF14","canonicalUrl":"https://aoctrl.com/siemens/3RW5513-1HF14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5513-1HF14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5513-1HF14 soft starter, rated 200-480 V, trip class 10A/10E/20E/30E per IEC 60947-4-2, ATEX and IECEx certified, UL and CSA approved, PROFIBUS/Modbus/EtherNet/IP, analog output 4-20 mA / 0-10 V, fail-safe input, 152 x 170 x 275 mm.","salesMarkdown":"## Application fit for motor starting and protection This Siemens 3RW5513-1HF14 soft starter is designed for three-phase induction motors in the 200-480 V range, with trip class selectable between 10A, 10E, 20E, and 30E per IEC 60947-4-2 — the trip class determines how long the starter can sustain an overload before disconnecting, so 10A suits fast-starting loads like conveyors while 30E handles high-inertia loads like centrifuges. The ATEX and IECEx certification means it can be installed in Zone 1 or Zone 2 explosive atmospheres — the soft starter itself isn't the ignition source, but the motor circuit it controls may be in the hazardous area, and this unit provides the necessary isolation and protection. With UL and CSA approval, this unit meets North American code requirements for panel installations — no need for additional agency-listed external overload relays if the starter is used within its rated motor FLA. ## Fieldbus integration and control interfaces The 3RW5513-1HF14 supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP — this covers the majority of industrial Ethernet and serial fieldbus standards, so it drops into a Siemens S7 environment or a Rockwell ControlLogix network without a protocol gateway. The analog output can be configured as 4-20 mA or 0-10 V, providing motor current or torque feedback to a PLC or drive controller — useful for closed-loop torque control or pump applications where the ramp-down profile needs to match system pressure. A fail-safe input allows the soft starter to be wired into a safety circuit — when the safety relay opens, the starter goes to a safe state (open load circuit per), stopping the motor without relying on the fieldbus or PLC logic. ## Motor control features for pump and torque applications Voltage ramp provides a controlled acceleration profile — for pump starts this reduces water hammer, and for conveyor starts it limits mechanical shock to the belt and gearbox. Pump ramp down is a dedicated deceleration feature that matches the motor torque to the pump's head curve during stop, preventing pressure surges and pipe vibration that a simple coast-to-stop would cause. Torque control and DC braking give the starter the ability to hold or stop the load under controlled torque — DC braking is particularly useful for stopping high-inertia loads quickly without mechanical brake wear. The service factor of 1.15 means the starter can handle a motor running at 115% of its rated load continuously — this is common in pump and fan applications where the motor is selected with a service factor margin. ## Mounting and clearance requirements Dimensions are 152 mm deep, 170 mm wide, 275 mm high — the unit mounts on a backplate or DIN rail in a standard enclosure. Required clearances: 100 mm above, 10 mm in front, 75 mm below, 5 mm at the sides, and 0 mm behind. ## Diagnostics and data logging The starter includes an event list, error logbook, and trace function — these store the last several fault events with timestamps, which helps a technician diagnose intermittent trips without needing a separate data logger. Motor heating is monitored and modelled internally, allowing the starter to calculate thermal capacity usage and protect the motor from overheating even under repeated start cycles — this is a key feature for applications with frequent starts like crushers or punch presses. Accuracy class 5 per IEC 61557-12 means the current measurement is within ±5% — sufficient for overload protection and basic energy monitoring, but not for billing-grade metering.","metaTitle":"Siemens 3RW5513-1HF14 Soft Starter, 200-480 V, ATEX, UL","metaDescription":"Siemens 3RW5513-1HF14 soft starter rated 200-480 V, trip class 10A/10E/20E/30E per IEC 60947-4-2. ATEX, IECEx, UL, CSA approved. PROFIBUS, Modbus, EtherNet/IP.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"152 mm","IECEx":"Yes","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5513-1HF14","Height":"275 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","B10d value":"1 588 000","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Safe State":"Open load circuit","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 480 V","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 13 A, 110-250 V AC, Screw terminals Fail-safe","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"Yes","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","With Fail-Safe":"1","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Product Designation":"Failsafe soft starters","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"22.5 A","at 50 °C rated value":"19.9 A","at 60 °C rated value":"18.2 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 normally-closed contact (NC) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"No","according to IEC 61508":"SIL1","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"4 W","at 50 °C after startup":"3 W","at 60 °C after startup":"3 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A, Class B on request","Emergency Operation Mode":"Yes","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"2.3 kg","at 40 °C during startup":"198 W","at 50 °C during startup":"166 W","at 60 °C during startup":"148 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","Safe failure fraction (SFF)":"60 %","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"11/22/2019","at 40 °C rated value minimum":"2.5 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"480 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"3 kW","at 400 V at 40 °C rated value":"5.5 kW","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"2 hp","at 220/230 V at 50 °C rated value":"3 hp","at 460/480 V at 50 °C rated value":"7.5 hp","of circuit breaker usable at 400 V":"3RV2032-4TA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4TA10; Type of coordination 1, Iq = 18 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"2","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","stop category according to EN 60204-1":"0","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Number of digital outputs with fail-safe":"1","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"2","average diagnostic coverage level (DCavg)":"90 %","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"18 ... 22 lbf·in","safety device type according to IEC 61508-2":"Type B","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"165 mA","hardware fault tolerance according to IEC 61508":"0","utilization category according to IEC 60947-4-2":"AC 53a","PFHD with high demand rate according to EN 62061":"1E-6 1/h","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","SIL Claim Limit (subsystem) according to EN 62061":"SIL 1","Control Supply Current In Standby Mode Rated Value":"100 mA","PFDavg with low demand rate according to IEC 61508":"0.09","performance level (PL) according to EN ISO 13849-1":"c","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"0.2 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 18 kA, CLASS 10","Diagnostics Test Interval By Internal Test Function Maximum":"1 000 s","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"43 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8017-1; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"1.6 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1815-0; Type of coordination 2, Iq = 65 kA","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","OFF-delay time with safety-related request when switched off via control inputs maximum":"100 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8d49daa773e7ec493c73dc6ce7944711.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830934&mlfb=3RW5513-1HF14"},"ai":{"faq":[{"question":"What is the ATEX certification on 3RW5513-1HF14?","answer":"The 3RW5513-1HF14 carries ATEX and IECEx certification, meaning it is approved for installation in potentially explosive atmospheres per the ATEX directive and IECEx scheme. This covers both gas and dust environments depending on the specific equipment group and category — the soft starter itself is not an ignition source but is suitable for controlling motors in hazardous areas."},{"question":"What fieldbus protocols does 3RW5513-1HF14 support?","answer":"It supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP. This covers the major industrial networks — Siemens PROFIBUS/PROFINET environments, Modbus-based SCADA systems, and Rockwell/Allen-Bradley EtherNet/IP networks — without requiring additional gateways."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5513-1HF14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5513-1HF14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}