{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5513-3HA14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5513-3HA14","canonicalUrl":"https://aoctrl.com/siemens/3RW5513-3HA14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5513-3HA14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5513-3HA14 soft starter, 200-480 V rated, ATEX, IECEx, trip class 10A/10E/20E/30E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, 170 mm width, 275 mm height, 152 mm depth.","salesMarkdown":"## What this soft starter delivers that a basic starter cannot The 3RW5513-3HA14 is a Siemens soft starter rated for 200-480 V motor supply, with trip class options 10A, 10E (default), 20E, or 30E per IEC 60947-4-2. That trip class range means you can match the overload protection to the motor's thermal capacity and starting duty — a pump with a long acceleration time gets 30E, while a fast-starting conveyor stays at 10A. It carries ATEX and IECEx certification, so it is approved for installation in explosive atmospheres — not just a general-purpose starter. The control supply accepts 110-250 V at 50 or 60 Hz, which covers most plant auxiliary voltages without a separate transformer. Fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIenergy. That means it integrates into a PLC-based line without a gateway — the same part handles both discrete and networked control. ## Mounting and panel integration — clearances that matter The unit measures 170 mm wide, 275 mm high, and 152 mm deep. Forced-air clearance: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and zero behind. That zero-backwards clearance means it can sit flush against the back panel — no wasted depth. Solid wire connections accept 2x (1.0-2.5 mm²) and 2x (2.5-10 mm²) per terminal. No screw terminals — the connection method is not listed as screw type, so expect spring-cage or push-in; verify the termination style from the product drawing before wiring. ## Soft-start features for pump and conveyor duty Voltage ramp and pump ramp down let you tailor acceleration and deceleration to the load — a pump gets a soft stop to avoid water hammer, a conveyor gets a controlled start to prevent product shift. Torque control and breakaway pulse handle high breakaway torque loads like crushers or mixers. DC braking and motor heating are built in — DC braking stops the motor quickly without a mechanical brake, and motor heating keeps windings dry in humid environments. Analog output can be set to 4-20 mA or 0-10 V for feeding motor current or power to a PLC or panel meter. Service factor 1.15 means the starter can handle 115% of rated current continuously — useful when the motor is oversized or running at the edge of its thermal limit. ## Diagnostics and lifecycle management Event list, error logbook, and trace function are standard — these record start/stop events, fault history, and parameter changes, which helps with root-cause analysis on a tripped line. Firmware update capability means the unit can be upgraded in the field without replacing hardware. Accuracy class 5 per IEC 61557-12 applies to the measurement functions — current and voltage readings are within 5% of true value, adequate for monitoring but not for billing-grade metering.","metaTitle":"Siemens 3RW5513-3HA14 Soft Starter, 200-480 V, ATEX","metaDescription":"Siemens 3RW5513-3HA14 soft starter, 200-480 V rated, ATEX/IECEx certified, trip class 10A/10E/20E/30E per IEC 60947-4-2. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"152 mm","Width":"170 mm","Height":"275 mm","Mounting":"screw fixing","Trip Class":"CLASS 10 A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","Product Status":"Active","Service Factor":"1.15","Digital Output Version":"3 normally-open contacts (NO) / 1 changeover contact (CO)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8083e6caf765c35266e3a0e6b43e3de5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830938&mlfb=3RW5513-3HA14","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RW5513-3HA14/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5513-3HA14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5513-3HA14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}