{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5513-3HA15","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5513-3HA15","canonicalUrl":"https://aoctrl.com/siemens/3RW5513-3HA15","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5513-3HA15","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RW5513-3HA15 soft starter, ATEX/IECEx, rated voltage 200…600 V, control supply 110…250 V AC, trip class 10A/10E/20E/30E per IEC 60947-4-2, PROFIBUS, analog output 4…20 mA / 0…10 V, UL/CSA.","salesMarkdown":"The Siemens 3RW5513-3HA15 is a SIRIUS soft starter for three-phase induction motors on a 200…600 V supply. Trip class CLASS 10A / 10E (default) / 20E / 30E per IEC 60947-4-2 governs disconnect time during a stall or overload. Control power is 110…250 V at 50 or 60 Hz, so it accepts common panel voltages without a separate transformer. The analog output defaults to 4…20 mA but can be switched to 0…10 V — useful for feeding a PLC analog input or a local meter without an external signal conditioner. ATEX and IECEx certification (both listed as Yes) means this unit is approved for installation in potentially explosive atmospheres. The unit measures 170 mm wide × 275 mm high × 152 mm deep. Forced-air clearance: 100 mm above, 75 mm below, 10 mm in front, 0 mm behind, and 5 mm at the sides. That 0 mm rear clearance means it can sit flush against a backplate — useful when panel depth is tight. The 5 mm side gap is minimal; adjacent devices won't crowd the airflow as long as you respect the vertical spacing. Power terminals accept 2× (1.0…2.5 mm²) or 2× (2.5…10 mm²) solid/stranded conductors. No screw terminals — the connection type is not listed as screw, so expect spring-cage or ring-lug terminations; verify the lug type against your panel wiring practice. ## Communication and control features PROFIBUS is built in (Yes), so no separate communication module is needed for a PROFIBUS DP network. Modbus TCP is also supported; Modbus RTU and EtherNet/IP are not. For PROFINET environments, PROFIenergy is available when paired with a PROFINET High-Feature communication module — useful for energy-management profiles during idle phases. The starter includes voltage ramp, pump ramp down, torque control, breakaway pulse, DC braking, and motor heating. Service factor is 1.15. Diagnostics include an event list, error logbook, and trace function. The unit supports auto-reset and remote reset, and firmware can be updated in the field. Up to four parameterizable sets are available — handy if the same starter serves multiple motor sizes or duty cycles. ## Approvals and sourcing UL and CSA approvals are listed (Yes), so the unit carries a cULus mark for North American panels. CE marking is also present. The ATEX and IECEx certifications are the key regulatory differentiator for hazardous-location installations.","metaTitle":"Siemens 3RW5513-3HA15 Soft Starter, ATEX, 200…600 V","metaDescription":"Siemens 3RW5513-3HA15 soft starter with ATEX/IECEx, trip class 10A/10E/20E/30E, rated 200…600 V, PROFIBUS, UL/CSA. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"152 mm","IECEx":"Yes","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5513-3HA15","Height":"275 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"No","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"No","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 600 V","UL approval":"Yes","description":"SIRIUS soft starter 200-600 V 13 A, 110-250 V AC spring-type terminals","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"No","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Product Designation":"Soft starter","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","PROFINET high-feature":"No","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"22.5 A","at 50 °C rated value":"19.9 A","at 60 °C rated value":"18.2 A","Communication Function":"Yes","Digital Output Version":"3 normally-open contacts (NO) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"Yes","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"4 W","at 50 °C after startup":"3 W","at 60 °C after startup":"3 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A, Class B on request","Emergency Operation Mode":"Yes","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"2.3 kg","at 40 °C during startup":"198 W","at 50 °C during startup":"166 W","at 60 °C during startup":"148 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.","Number Of Digital Outputs":"4","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-25 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at 40 °C rated value minimum":"2.5 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"600 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"3 kW","at 400 V at 40 °C rated value":"5.5 kW","at 500 V at 40 °C rated value":"7.5 kW","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"600 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"2 hp","at 220/230 V at 50 °C rated value":"3 hp","at 460/480 V at 50 °C rated value":"7.5 hp","at 575/600 V at 50 °C rated value":"10 hp","of circuit breaker usable at 400 V":"3RV2032-4TA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4TA10; Type of coordination 1, Iq = 18 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"3","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"165 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"100 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"0.2 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"5 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 18 kA, CLASS 10","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"43 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8017-1; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"1.6 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1815-0; Type of coordination 2, Iq = 65 kA","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ddfcd0832090402dcddb3cd469d21291.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830939&mlfb=3RW5513-3HA15"},"ai":{"faq":[{"question":"Does 3RW5513-3HA15 support PROFIBUS communication?","answer":"Yes, PROFIBUS is built in. Modbus TCP is also supported. Modbus RTU and EtherNet/IP are not available. PROFIenergy requires a PROFINET High-Feature communication module."},{"question":"What is 3RW5513-3HA15's listed ATEX certification?","answer":"ATEX is listed as Yes, along with IECEx. This certifies the soft starter for use in potentially explosive atmospheres per the ATEX directive and IECEx scheme."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5513-3HA15","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5513-3HA15 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}