{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5513-3HF04","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5513-3HF04","canonicalUrl":"https://aoctrl.com/siemens/3RW5513-3HF04","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5513-3HF04","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5513-3HF04 soft starter, 200-480 V, ATEX, IECEx, trip classes 10A/10E/20E/30E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, analog output 4-20 mA / 0-10 V.","salesMarkdown":"## Hazardous-area soft starter with multi-protocol fieldbus The Siemens 3RW5513-3HF04 is a soft starter carrying ATEX and IECEx certification, so it can be installed in Zone 2 / Zone 22 hazardous areas where motor starting must avoid ignition sources. Rated for 200-480 V AC supply, it covers the common low-voltage motor voltages found in European and North American industrial plants — no transformer needed for 230 V or 400 V feeds. ## Fieldbus and analog feedback for control integration Built-in PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP support means this soft starter talks directly to most common PLC networks without an external gateway — parameterize the start ramp, current limit, and fault log over the bus. The analog output can be configured as 4-20 mA or 0-10 V to feed motor current or voltage to a local indicator or remote I/O — useful for trending start current or monitoring load changes. ## Safety, reliability, and motor protection features The B10d value of 1,588,000 cycles is a reliability figure for the safety-related parts — relevant when the soft starter is used in a safety function like safe torque off (the safe state is open load circuit). Motor heating function provides thermal protection by modeling the motor's temperature rise during starting, reducing nuisance trips on long acceleration times. Service factor 1.15 allows the soft starter to handle 15% continuous overload above its rated current without tripping — typical for pumps and fans that occasionally run above nameplate. DC braking, pump ramp down, breakaway pulse, and torque control are all built in — no external braking module needed for controlled stopping or jogging. ## Regulatory approvals and compliance documentation UL and CSA approvals cover North American installations; CE marking covers the European low-voltage and EMC directives. ATEX and IECEx certification means the unit carries a nameplate marking suitable for explosive atmospheres — the documentation package includes the certificate number for the panel builder's dossier. ## Mounting dimensions and clearance requirements The unit measures 152 mm deep, 170 mm wide, and 275 mm high — fits a standard 400 mm wide enclosure depth. Minimum clearance around the unit: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind — plan the enclosure layout so ventilation airflow is not blocked. Power wiring terminals accept solid conductors from 1.0 to 10 mm² — two terminals per phase for daisy-chaining or dual-cable runs.","metaTitle":"Siemens 3RW5513-3HF04 Soft Starter, 200-480 V, ATEX","metaDescription":"Siemens 3RW5513-3HF04 soft starter, rated 200-480 V, ATEX/IECEx certified, trip classes 10A-30E, PROFIBUS/Modbus/EtherNet/IP. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"152 mm","IECEx":"Yes","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5513-3HF04","Height":"275 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","B10d value":"1 588 000","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Safe State":"Open load circuit","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 480 V","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 13 A, 24 V AC/DC spring-type terminals Fail-safe","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"No","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","With Fail-Safe":"1","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Product Designation":"Failsafe soft starters","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"22.5 A","at 50 °C rated value":"19.9 A","at 60 °C rated value":"18.2 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 normally-closed contact (NC) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"Yes","according to IEC 61508":"SIL1","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"4 W","at 50 °C after startup":"3 W","at 60 °C after startup":"3 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","Emergency Operation Mode":"Yes","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"2.3 kg","at 40 °C during startup":"198 W","at 50 °C during startup":"166 W","at 60 °C during startup":"148 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","Safe failure fraction (SFF)":"60 %","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"11/22/2019","at 40 °C rated value minimum":"2.5 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"480 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"3 kW","at 400 V at 40 °C rated value":"5.5 kW","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"2 hp","at 220/230 V at 50 °C rated value":"3 hp","at 460/480 V at 50 °C rated value":"7.5 hp","of circuit breaker usable at 400 V":"3RV2032-4TA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4TA10; Type of coordination 1, Iq = 18 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"2","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","stop category according to EN 60204-1":"0","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Number of digital outputs with fail-safe":"1","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"2","average diagnostic coverage level (DCavg)":"90 %","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"18 ... 22 lbf·in","safety device type according to IEC 61508-2":"Type B","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"820 mA","hardware fault tolerance according to IEC 61508":"0","utilization category according to IEC 60947-4-2":"AC 53a","PFHD with high demand rate according to EN 62061":"1E-6 1/h","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","SIL Claim Limit (subsystem) according to EN 62061":"SIL 1","Control Supply Current In Standby Mode Rated Value":"420 mA","PFDavg with low demand rate according to IEC 61508":"0.09","performance level (PL) according to EN ISO 13849-1":"c","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"0.91 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 18 kA, CLASS 10","Diagnostics Test Interval By Internal Test Function Maximum":"1 000 s","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"7.5 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8017-1; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"20 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1815-0; Type of coordination 2, Iq = 65 kA","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","OFF-delay time with safety-related request when switched off via control inputs maximum":"100 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aefc84da5f1101e5bcde20cffd57aac5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830940&mlfb=3RW5513-3HF04"},"ai":{"faq":[{"question":"Where can I buy 3RW5513-3HF04 and get a price?","answer":"This soft starter is available to order against an RFQ. Submit a request with your target quantity and delivery timeline; we will confirm availability and current pricing from our supply chain."},{"question":"What compliance documentation does Siemens provide for 3RW5513-3HF04?","answer":"The unit carries UL, CSA, and CE approvals plus ATEX and IECEx certification. The manufacturer provides a declaration of conformity and the ATEX certificate as part of the documentation package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5513-3HF04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5513-3HF04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}