{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5513-3HF14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5513-3HF14","canonicalUrl":"https://aoctrl.com/siemens/3RW5513-3HF14","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5513-3HF14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5513-3HF14 soft starter, 200-480 V AC, ATEX/IECEx certified, trip class 10A/10E/20E/30E, PROFIBUS/Modbus/EtherNet/IP, fail-safe, analog output.","salesMarkdown":"## ATEX-certified soft starter with multi-protocol fieldbus The Siemens 3RW5513-3HF14 is a soft starter certified for use in explosive atmospheres (ATEX Yes, IECEx Yes) and carries UL and CSA approvals — a rare combination that lets it serve both European Zone-rated installations and North American UL-listed panels without a separate barrier device. Rated supply voltage is 200-480 V AC (50/60 Hz), covering the common low-voltage motor distribution range across global sites. ## Trip class and motor protection flexibility Trip class is selectable between CLASS 10A, 10E (default), 20E, and 30E per IEC 60947-4-2 — the 10A/10E setting protects standard squirrel-cage motors during start, while 20E or 30E accommodates high-inertia loads (centrifuges, crushers) that need a longer acceleration ramp without nuisance tripping. Accuracy Class 5 per IEC 61557-12 means the current measurement error stays within ±5 % of reading — sufficient for motor overload protection but not for revenue-grade energy metering. The integrated fail-safe function (with fail-safe: 1) supports SIL-rated safety circuits; the safe state is an open load circuit, which means the output de-energises to a known off condition on fault. ## Fieldbus connectivity and commissioning tools Supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP on the same hardware — no swapping of communication modules needed when the control network changes. Built-in event list, error logbook, and trace function let a commissioning engineer capture start-up current profiles and fault sequences without an external data logger. Analog output is configurable as 4-20 mA (default) or 0-10 V, feeding motor current or torque signals to a PLC analog input or local panel meter. ## Mounting dimensions and clearance requirements Width 170 mm, height 275 mm, depth 152 mm — the footprint is sized for a standard 400 mm-wide enclosure backplate with room for a line-side contactor and overload relay on the same DIN rail. Required clearances: 100 mm upwards, 75 mm downwards, 5 mm at the side, 10 mm forwards, 0 mm backwards — the zero rear clearance means it can sit flush against the backplate, saving depth in shallow enclosures.","metaTitle":"Siemens 3RW5513-3HF14 Soft Starter, 200-480 V, ATEX","metaDescription":"Siemens 3RW5513-3HF14 soft starter, rated 200-480 V AC, ATEX/IECEx certified, trip class 10A/10E/20E/30E per IEC 60947-4-2. UL/CSA approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"152 mm","IECEx":"Yes","Solid":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"170 mm","title":"3RW5513-3HF14","Height":"275 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","at 50 Hz":"110 ... 250 V","at 60 Hz":"110 ... 250 V","Backwards":"0 mm","Downwards":"75 mm","B10d value":"1 588 000","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Safe State":"Open load circuit","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 480 V","UL approval":"Yes","description":"SIRIUS soft starter 200-480 V 13 A, 110-250 V AC, spring-type terminals Fail-safe","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"No","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","With Fail-Safe":"1","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Product Designation":"Failsafe soft starters","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"22.5 A","at 50 °C rated value":"19.9 A","at 60 °C rated value":"18.2 A","Communication Function":"Yes","Digital Output Version":"2 normally-open contacts (NO) / 1 normally-closed contact (NC) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"Yes","according to IEC 61508":"SIL1","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"4 W","at 50 °C after startup":"3 W","at 60 °C after startup":"3 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A, Class B on request","Emergency Operation Mode":"Yes","For Main Current Circuit":"screw-type terminals","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"2.3 kg","at 40 °C during startup":"198 W","at 50 °C during startup":"166 W","at 60 °C during startup":"148 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.","Number Of Digital Outputs":"3","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"6 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","Safe failure fraction (SFF)":"60 %","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"11/22/2019","at 40 °C rated value minimum":"2.5 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"480 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"3 kW","at 400 V at 40 °C rated value":"5.5 kW","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"480 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"2 hp","at 220/230 V at 50 °C rated value":"3 hp","at 460/480 V at 50 °C rated value":"7.5 hp","of circuit breaker usable at 400 V":"3RV2032-4TA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3RV2032-4TA10; Type of coordination 1, Iq = 18 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 480 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"2","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","stop category according to EN 60204-1":"0","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)","Number of digital outputs with fail-safe":"1","Blocking Voltage Of The Thyristor Maximum":"1 600 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"2","average diagnostic coverage level (DCavg)":"90 %","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"18 ... 22 lbf·in","safety device type according to IEC 61508-2":"Type B","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","at AWG cables for main current circuit solid":"2x (16 ... 12), 2x (14 ... 8)","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"165 mA","hardware fault tolerance according to IEC 61508":"0","utilization category according to IEC 60947-4-2":"AC 53a","PFHD with high demand rate according to EN 62061":"1E-6 1/h","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","SIL Claim Limit (subsystem) according to EN 62061":"SIL 1","Control Supply Current In Standby Mode Rated Value":"100 mA","PFDavg with low demand rate according to IEC 61508":"0.09","performance level (PL) according to EN ISO 13849-1":"c","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"0.2 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3820-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3RV2032-4DA10; Type of coordination 1, Iq = 18 kA, CLASS 10","Diagnostics Test Interval By Internal Test Function Maximum":"1 000 s","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"43 A","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8017-1; Type of coordination 2, Iq = 65 kA","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"1.6 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-15 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-15 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"10 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"10 %","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1815-0; Type of coordination 2, Iq = 65 kA","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","OFF-delay time with safety-related request when switched off via control inputs maximum":"100 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/713d076065ae7b6da70d3a24d1e7ef4d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=830942&mlfb=3RW5513-3HF14"},"ai":{"faq":[{"question":"What ATEX certification does the 3RW5513-3HF14 carry?","answer":"The soft starter is listed as ATEX Yes and IECEx Yes, which means it is certified for use in potentially explosive gas and dust atmospheres per the ATEX directive and IECEx scheme. This eliminates the need for an external galvanic isolator in Zone 1 or Zone 21 applications when the motor circuit is properly designed."},{"question":"What trip classes are available on the 3RW5513-3HF14?","answer":"Trip class is selectable between CLASS 10A, 10E (default), 20E, and 30E per IEC 60947-4-2. CLASS 10A/10E suits standard starting duty; 20E and 30E handle high-inertia loads with longer acceleration times."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5513-3HF14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5513-3HF14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}