{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5521-3HA06","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5521-3HA06","canonicalUrl":"https://aoctrl.com/siemens/3RW5521-3HA06","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5521-3HA06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5521-3HA06 soft starter, 200-690 V rated voltage, ATEX and IECEx certified, trip class 10A/10E default, UL/CSA approved, active production.","salesMarkdown":"## Rated voltage range and trip class selection The 3RW5521-3HA06 is rated for 200 to 690 V, covering 208 V, 240 V, 400 V, 480 V, and 600 V nominal systems without a voltage tap change — one unit spans the low-voltage motor range common in North American and European installations. Trip class defaults to CLASS 10A or 10E per IEC 60947-4-2, with selectable 20E and 30E for higher-inertia loads. CLASS 10A limits the thermal overload to 10 seconds at locked-rotor current, protecting standard squirrel-cage motors during start; 20E or 30E extends the window for loads like centrifuges or crushers that need a longer acceleration ramp. ## ATEX, IECEx, and North American approvals ATEX and IECEx certification are listed on the unit, confirming compliance with explosive atmosphere directives for gas and dust groups — suitable for Zone 1/21 or Zone 2/22 installations per the equipment group and temperature class on the nameplate. UL and CSA approval are both present, so the soft starter is accepted in North American panels without additional agency review — a requirement for UL 508A listed assemblies. ## Fieldbus connectivity and analog output Modbus RTU, Modbus TCP, and EtherNet/IP are built in — no external gateway needed for these three protocols. PROFIBUS and PROFINET require optional communication modules; PROFIenergy is supported in conjunction with PROFINET High-Feature modules. The analog output is configurable as 4–20 mA or 0–10 V, defaulting to 4–20 mA, and can be mapped to motor current or load signal for SCADA trending without a separate current transformer. ## Operating temperature and panel clearance This affects enclosure sizing and ventilation design. Physical dimensions are 306 mm height, 185 mm width, and 203 mm depth. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward — the zero backward clearance allows flush mounting against a panel backplate, but the forward clearance must be maintained for wiring access and airflow.","metaTitle":"Siemens 3RW5521-3HA06 Soft Starter, 200-690 V, ATEX, Active","metaDescription":"Siemens 3RW5521-3HA06 soft starter, rated 200-690 V, ATEX/IECEx certified, trip class 10A/10E default. Active production, UL/CSA approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"203 mm","IECEx":"Yes","Width":"185 mm","title":"3RW5521-3HA06","Height":"306 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 690 V","UL approval":"Yes","description":"SIRIUS soft starter 200-690 V 25 A, 24 V AC/DC spring-type terminals","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"No","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"spring-loaded terminals","Product Designation":"Soft starter","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes; Only up to 600 V operating voltage","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"43.3 A","at 50 °C rated value":"39 A","at 60 °C rated value":"33.9 A","Communication Function":"Yes","Digital Output Version":"3 normally-open contacts (NO) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"Yes","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"8 W","at 50 °C after startup":"7 W","at 60 °C after startup":"6 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","Emergency Operation Mode":"Yes","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"5.5 kg","at 40 °C during startup":"332 W","at 50 °C during startup":"283 W","at 60 °C during startup":"239 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"2x (0.25 ... 1.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"4","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"8 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at 40 °C rated value minimum":"5 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"690 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"5.5 kW","at 400 V at 40 °C rated value":"11 kW","at 500 V at 40 °C rated value":"15 kW","at 690 V at 40 °C rated value":"22 kW","Width Of Connection Bar Maximum":"25 mm","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"690 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"5 hp","at 220/230 V at 50 °C rated value":"7.5 hp","at 460/480 V at 50 °C rated value":"15 hp","at 575/600 V at 50 °C rated value":"20 hp","At Inside-Delta Circuit Rated Value":"200 ... 600 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"8 kV","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"2x (24 ... 16)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 800 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"3","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"870 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"440 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"6.3 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3824-6; Type of coordination 1, Iq = 65 kA","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"7.5 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE8021-1; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"20 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1817-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","at AWG cables for control circuit finely stranded with core end processing":"2x (24 ... 16)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d95df1189d3396046d58bd2d91682cd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=831010&mlfb=3RW5521-3HA06"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for the 3RW5521-3HA06?","answer":"The unit carries CE marking, UL approval, and CSA approval. ATEX and IECEx certification are also listed. These cover the major regulatory jurisdictions for industrial motor control equipment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5521-3HA06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5521-3HA06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}