{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RW5525-1HA06","brand":"Siemens","brandSlug":"siemens","productSlug":"3RW5525-1HA06","canonicalUrl":"https://aoctrl.com/siemens/3RW5525-1HA06","factsUrl":"https://aoctrl.com/api/mcp/products/3RW5525-1HA06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RW5525-1HA06 soft starter, 200-690 V, ATEX & IECEx certified, trip class 10A/10E/20E/30E, screw terminals, 185 x 306 x 203 mm.","salesMarkdown":"## Trip class flexibility and voltage range The 3RW5525-1HA06: Trip class is configurable between CLASS 10A, 10E (default), 20E, and 30E per IEC 60947-4-2. The rated voltage covers 200 to 690 V, which handles most global supply systems from 208 V to 600 V without a transformer. ## Fieldbus connectivity and control features Communication options include PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP, plus PROFINET with PROFIenergy capability when fitted with the appropriate communication module. The unit also supports DC braking and combined braking, which can be configured to stop the motor faster than coasting — useful for conveyors or pumps where backspin is undesirable. Torque control and a breakaway pulse are available for starting high-friction loads like screw compressors or belt conveyors. ## Temperature derating and panel clearance Minimum clearance around the unit: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm sideways, and 0 mm backwards. That means the unit can be mounted flush against the back panel, saving depth in the enclosure. Dimensions are 185 mm wide, 306 mm high, and 203 mm deep. ## Approvals and compliance documentation CE, UL, and CSA approvals are all confirmed on this order code, covering European and North American installations. Accuracy class 5 per IEC 61557-12 applies to the integrated metering function. The unit also includes a service factor of 1.15, so it can handle continuous overloads up to 115 % of the rated current without tripping.","metaTitle":"Siemens 3RW5525-1HA06 Soft Starter, 200-690 V, ATEX","metaDescription":"Siemens 3RW5525-1HA06 soft starter, active production, rated 200-690 V, ATEX & IECEx certified. Trip class 10A/10E/20E/30E. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"ATEX":"Yes","Depth":"203 mm","IECEx":"Yes","Width":"185 mm","title":"3RW5525-1HA06","Height":"306 mm","Upwards":"100 mm","Forwards":"10 mm","PROFIBUS":"Yes","Backwards":"0 mm","Downwards":"75 mm","CE marking":"Yes","DC braking":"Yes","Event List":"Yes","Modbus RTU":"Yes","Modbus TCP":"Yes","Trip Class":"CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2","auto-RESET":"Yes","At The Side":"5 mm","EtherNet/IP":"Yes","PROFIenergy":"Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules","Rated Value":"200 ... 690 V","UL approval":"Yes","description":"SIRIUS soft starter 200-690 V 63 A, 24 V AC/DC Screw terminals","CSA approval":"Yes","Remote Reset":"Yes","Voltage Ramp":"Yes","Analog Output":"Yes; 4 ... 20 mA (default) / 0 ... 10 V","Error Logbook":"Yes","Motor Heating":"Yes","Accuracy Class":"5 (based on IEC 61557-12)","Pump Ramp Down":"Yes","Screw Terminal":"Yes","Service Factor":"1.15","Torque Control":"Yes","Trace Function":"Yes","Breakaway Pulse":"Yes","Firmware Update":"Yes","Parameterizable":"4","lifecycle_stage":"current","Combined Braking":"Yes","During Operation":"-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above","Fastening Method":"screw fixing","HMI-High Feature":"Yes","Minimum Load [%]":"10 %; Relative to set Ie","Product Category":"Hybrid switching devices","Shock Resistance":"15 g / 11 ms, from 6 g / 11 ms with potential contact lifting","Start Torque [%]":"10 ... 100 %","Mounting Position":"Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)","PROFINET standard":"Yes","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Application Wizards":"Yes","Degree Of Pollution":"3, acc. to IEC 60947-4-2","For Control Circuit":"screw-type terminals","Product Designation":"Soft starter","Reversing Operation":"Yes","Stopping Torque [%]":"10 ... 100 %","Alternative Run-Down":"Yes","Condition Monitoring":"Yes","Idle Time Adjustable":"0 ... 255 s","Inside-Delta Circuit":"Yes; Only up to 600 V operating voltage","Starting Voltage [%]":"20 ... 100 %","Stopping Voltage [%]":"50 %; non-adjustable","Vibration Resistance":"15 mm up to 6 Hz; 2 g up to 500 Hz","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","PROFINET high-feature":"Yes","Ramp-Down (Soft Stop)":"Yes","Torque Limitation [%]":"20 ... 200 %","at 40 °C rated value":"109 A","at 50 °C rated value":"96 A","at 60 °C rated value":"87.5 A","Communication Function":"Yes","Digital Output Version":"3 normally-open contacts (NO) / 1 changeover contact (CO)","Slave Pointer Function":"Yes","Spring-Loaded Terminal":"No","Ramp-Up (Soft Starting)":"Yes","at 40 °C after startup":"19 W","at 50 °C after startup":"17 W","at 60 °C after startup":"15 W","EMC emitted interference":"acc. to IEC 60947-4-2: Class A","Emergency Operation Mode":"Yes","For Main Current Circuit":"box terminal","Number Of Analog Outputs":"1","Number Of Digital Inputs":"4","Number Of Parameter Sets":"3","Weight Without Packaging":"5.9 kg","at 40 °C during startup":"1 056 W","at 50 °C during startup":"732 W","at 60 °C during startup":"647 W","Breakaway Time Adjustable":"0 ... 2 s","For Control Circuit Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Motor Overload Protection":"Yes; Full motor protection (thermistor motor protection and electronic motor overload protection)","Number Of Digital Outputs":"4","Via Software Configurable":"Yes","Automatic Parameterisation":"Yes","Impulse Voltage Rated Value":"8 kV","Intrinsic Device Protection":"Yes","Number Of Controlled Phases":"3","During Storage And Transport":"-40 ... +80 °C","Type Of The Motor Protection":"Electronic, tripping in the event of thermal overload of the motor","Via Software Parameterizable":"Yes","at DC-13 at 24 V rated value":"1 A","Adjustable Current Limitation":"Yes","Electromagnetic Compatibility":"acc. to IEC 60947-4-2","Substance Prohibitance (Date)":"02/15/2018","at 40 °C rated value minimum":"13 A","at AC-15 at 250 V rated value":"3 A","is supported HMI-High Feature":"Yes","Insulation Voltage Rated Value":"690 V","Ramp-Down Time Of Soft Starter":"0 ... 360 s","at 230 V at 40 °C rated value":"18.5 kW","at 400 V at 40 °C rated value":"30 kW","at 500 V at 40 °C rated value":"37 kW","at 690 V at 40 °C rated value":"55 kW","Width Of Connection Bar Maximum":"25 mm","Breakaway Voltage [%] Adjustable":"40 ... 100 %","Control Supply Voltage Frequency":"50 ... 60 Hz","Operating Measured Value Display":"Yes","Operating frequency 1 rated value":"50 Hz","Operating frequency 2 rated value":"60 Hz","of high feature HMI module usable":"3RW5980-0HF00","of the gG fuse usable up to 690 V":"3NA3830-6; Type of coordination 1, Iq = 65 kA","Between Main And Auxiliary Circuit":"690 V; does not apply for thermistor connection","Start-Up Ramp Time Of Soft Starter":"0 ... 360 s","at 200/208 V at 50 °C rated value":"15 hp","at 220/230 V at 50 °C rated value":"20 hp","at 460/480 V at 50 °C rated value":"40 hp","at 575/600 V at 50 °C rated value":"50 hp","of circuit breaker usable at 400 V":"3VA2163-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V":"3VA2163-7MN32-0AA0; Type of coordination 1, Iq = 20 kA, CLASS 10","At Inside-Delta Circuit Rated Value":"200 ... 600 V","Programmable Control Inputs/Outputs":"Yes","at the digital inputs at DC maximum":"1 000 m","of communication module Ethernet/IP":"3RW5980-0CE00","Current Unbalance Limiting Value [%]":"10 ... 60 %","Design Of The Overvoltage Protection":"Varistor","Surge Voltage Resistance Rated Value":"8 kV","Current Limiting Value [%] Adjustable":"125 ... 800 %","during storage according to IEC 60721":"1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4","Between Soft Starter And Motor Maximum":"800 m","Removable Terminal For Control Circuit":"Yes","according to ATEX directive 2014/34/EU":"BVS 18 ATEX F 003 X","at AWG cables for control circuit solid":"1x (20 ... 12), 2x (20 ... 14)","during operation according to IEC 60721":"3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6","during transport according to IEC 60721":"2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)","of communication module PROFIBUS usable":"3RW5980-0CP00","reference code according to IEC 81346-2":"Q","Blocking Voltage Of The Thyristor Maximum":"1 800 V","Evaluation Of Thermistor Motor Protection":"Yes; Type A PTC or Klixon / Thermoclick","Number Of Digital Outputs Parameterizable":"3","of communication module Modbus RTU usable":"3RW5980-0CR00","of communication module Modbus TCP usable":"3RW5980-0CT00","Creep Speed In Both Directions Of Rotation":"Yes","Ground-Fault Monitoring Limiting Value [%]":"10 ... 95 %","Soft Starting At Heavy Starting Conditions":"Yes","For Main Contacts With Screw-Type Terminals":"40 ... 53 lbf·in","Recovery Time After Overload Trip Adjustable":"60 ... 1 800 s","Number Of Digital Outputs Not Parameterizable":"1","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Holding Current In Bypass Operation Rated Value":"870 mA","utilization category according to IEC 60947-4-2":"AC 53a","Product Feature Integrated Bypass Contact System":"Yes","of communication module PROFINET standard usable":"3RW5980-0CS00","Control Supply Current In Standby Mode Rated Value":"440 mA","Relative Negative Tolerance Of The Operating Voltage":"-15 %","Relative Positive Tolerance Of The Operating Voltage":"10 %","contact rating of auxiliary contacts according to UL":"R300-B300","of communication module PROFINET high-feature usable":"3RW5950-0CH00","Inrush Current By Closing The Bypass Contacts Maximum":"6.3 A","Design Of Short-Circuit Protection For Control Circuit":"4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m; Derating as of 1000 m, see catalog","of the gG fuse usable at inside-delta circuit up to 500 V":"3NA3830-6; Type of coordination 1, Iq = 65 kA","of circuit breaker usable at 400 V at inside-delta circuit":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","of circuit breaker usable at 500 V at inside-delta circuit":"3VA2110-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10","For Auxiliary And Control Contacts With Screw-Type Terminals":"7 ... 10.3 lbf·in","For Control Circuit Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","relative negative tolerance of the control supply voltage at DC":"-20 %","relative positive tolerance of the control supply voltage at DC":"20 %","For Main Contacts For Box Terminal Using Both Clamping Points Solid":"2x (2.5 ... 16 mm²)","Relative Negative Tolerance Of The Control Supply Voltage Frequency":"-10 %","Relative Positive Tolerance Of The Control Supply Voltage Frequency":"10 %","Inrush Current Peak At Application Of Control Supply Voltage Maximum":"7.5 A","For Main Contacts For Box Terminal Using Both Clamping Points Stranded":"2x (6 ... 16 mm²), 2x (10 ... 50 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Solid":"1x (2.5 ... 16 mm²)","of back-up R fuse link for semiconductor protection usable up to 690 V":"3NE3227; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Solid":"1x (2.5 ... 16 mm²)","Duration Of Inrush Current Peak At Application Of Control Supply Voltage":"20 ms","relative negative tolerance of the control supply voltage at AC at 50 Hz":"-20 %","relative negative tolerance of the control supply voltage at AC at 60 Hz":"-20 %","relative positive tolerance of the control supply voltage at AC at 50 Hz":"20 %","relative positive tolerance of the control supply voltage at AC at 60 Hz":"20 %","For Main Contacts For Box Terminal Using The Back Clamping Point Stranded":"1x (10 ... 70 mm²)","of full range R fuse link for semiconductor protection usable up to 690 V":"3NE1022-0; Type of coordination 2, Iq = 65 kA","For Main Contacts For Box Terminal Using The Front Clamping Point Stranded":"1x (10 ... 70 mm²)","Relative Negative Tolerance Of The Operating Voltage At Inside-Delta Circuit":"-15 %","Relative Positive Tolerance Of The Operating Voltage At Inside-Delta Circuit":"10 %","at AWG cables for main contacts for box terminal using the back clamping point":"1x (10 ... 2/0)","For Main Contacts For Box Terminal Using Both Clamping Points Finely Stranded With Core End Processing":"2x (2.5 ... 35 mm²)","For Main Contacts For Box Terminal Using The Back Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)","For Main Contacts For Box Terminal Using The Front Clamping Point Finely Stranded With Core End Processing":"1x (2.5 ... 50 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9650b79ddaf3cf86161a46c7bfc1d5a9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=831134&mlfb=3RW5525-1HA06"},"ai":{"faq":[{"question":"What trip classes can the 3RW5525-1HA06 be set to?","answer":"Trip class is configurable to CLASS 10A, 10E (default), 20E, or 30E per IEC 60947-4-2. The default is 10E, which covers most standard motor starts. For high-inertia loads requiring longer start times, select 20E or 30E."},{"question":"What fieldbus protocols does the 3RW5525-1HA06 support?","answer":"It supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP directly. PROFINET with PROFIenergy is available when used with the appropriate PROFINET High-Feature communication module."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RW5525-1HA06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RW5525-1HA06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}